Overloading study of bases using polymeric RP-HPLC columns as an aid to rationalization of overloading on silica-ODS phases

被引:74
作者
Buckenmaier, SMC
McCalley, DV [1 ]
Euerby, MR
机构
[1] Univ W England, Ctr Res Biomed, Bristol BS16 1QY, Avon, England
[2] AstraZeneca R&D Charnwood Lund, Pharmaceut & Analyt R&D, Loughborough LE11 5RH, Leics, England
关键词
D O I
10.1021/ac0202381
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The separation of ionized bases by reversed-phase liquid chromatography with alkyl silica columns often leads to severely tailed bands that are highly detrimental. Band shape and its dependence on sample mass are notably different when mobile-phase pH is changed, and this behavior has not been previously explained. Ionized silanols present in the stationary phase have been credited with a role in determining peak shape. In the present study, separations on two different polymer columns were compared with those previously obtained on alkyl silica phases. Because silanols are absent from polymer columns, this comparison enabled us to assess the role of silanols in separations on alkyl silica phases and to offer an explanation of why band shape changes with sample size and mobile-phase pH for both polymer and silica-based phases.
引用
收藏
页码:4672 / 4681
页数:10
相关论文
共 24 条
[1]   SOLVENT STRENGTH STUDIES ON POLYSTYRENE-DIVINYLBENZENE COLUMNS [J].
BOWERS, LD ;
PEDIGO, S .
JOURNAL OF CHROMATOGRAPHY, 1986, 371 :243-251
[2]   Retention of ionizable compounds on HPLC.: 6.: pH measurements with the glass electrode in methanol-water mixtures [J].
Canals, I ;
Oumada, FZ ;
Rosés, M ;
Bosch, E .
JOURNAL OF CHROMATOGRAPHY A, 2001, 911 (02) :191-202
[3]   PREPARATIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY UNDER ISOCRATIC CONDITIONS .3. THE CONSEQUENCES OF 2 ADJACENT BANDS HAVING UNEQUAL COLUMN CAPACITIES [J].
COX, GB ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1989, 483 :95-110
[4]   STUDY OF THE RETENTION MECHANISMS FOR BASIC COMPOUNDS ON SILICA UNDER PSEUDO-REVERSED-PHASE CONDITIONS [J].
COX, GB ;
STOUT, RW .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :315-336
[5]   SIMPLIFIED DESCRIPTION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION UNDER OVERLOAD CONDITIONS, BASED ON THE CRAIG DISTRIBUTION MODEL .2. EFFECT OF ISOTHERM TYPE, AND EXPERIMENTAL-VERIFICATION OF COMPUTER-SIMULATIONS FOR A SINGLE BAND [J].
EBLE, JE ;
GROB, RL ;
ANTLE, PE ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :45-79
[6]   Influence of solvent uptake and swelling by poly(styrene-divinylbenzene) column packings on sample sorption rate and band broadening in reversed-phase liquid chromatography [J].
Ells, B ;
Wang, Y ;
Cantwell, FF .
JOURNAL OF CHROMATOGRAPHY A, 1999, 835 (1-2) :3-18
[7]  
Euerby MR, 2000, LC GC EUR, V13, P665
[8]   EQUATIONS FOR CALCULATION OF CHROMATOGRAPHIC FIGURES OF MERIT FOR IDEAL AND SKEWED PEAKS [J].
FOLEY, JP ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :730-737
[9]   Peak tailing and mass transfer kinetics in linear chromatography [J].
Fornstedt, T ;
Zhong, GM ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1996, 741 (01) :1-12
[10]   Nonlinear effects in LC and chiral LC [J].
Fornstedt, T ;
Guiochon, G .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :608A-617A