Evaluation of PAC effect in integrated PAC/UF system for surface water treatment

被引:0
作者
Hu, Jing-yi [1 ]
Shang, Ran [1 ]
Deng, Hui-ping [1 ]
机构
[1] Tongji Univ, Minist Educ, Key Lab Yangtze River Aquat Environm, Shanghai, Peoples R China
来源
2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010) | 2010年
关键词
PAC; PAC/UF; membrane flux; AMW; Zeta potential; ULTRAFILTRATION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effect of powdered activated carbon (PAC) on the hybrid PAC/UF (PAC applied in combination with the ultrafiltration membrane) system was investigated in this paper. Compared to UF system, in which no PAC was added, the membrane flux was improved from 58.58% to 69.59% in terms of J/J(0) value for 200 minutes' filtration. In PAC/UF process, it is the fraction which cannot be adsorbed by PAC takes greater responsibility for membrane fouling, this fraction possesses the potential to cause more irreversible fouling, regardless of its low organic content. Analysis by technological apparatus revealed that the apparent molecular weight (AMW) of this fraction is less than 500Da or more than 10kDa, and the more than 10kDa part shows predominant, it is also easily retained on the membrane surface to produce fouling; Furthermore, this fraction exhibits almost positive Zeta potential, and can be preferentially absorbed by the negative membrane surface, so as to cause the relatively severe flux decline.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Effect of powdered activated carbon dosage on sludge properties and membrane bioreactor performance in a hybrid MBR-PAC system
    Zhang, Shi
    Zuo, Xingtao
    Xiong, Juan
    Ma, Cong
    Hu, Bo
    ENVIRONMENTAL TECHNOLOGY, 2019, 40 (09) : 1156 - 1165
  • [32] PILOT STUDY OF THE REMOVAL OF INDIVIDUAL TRIHALOMETHANES (thms) FROM CHLORINATED DRINKING WATER BY PAC ADSORPTION-GALATSI WATER TREATMENT PLANT, ATHENS, GREECE
    Babi, K. G.
    Koumenides, K. M.
    Nikolaou, A. D.
    Makri, C. A.
    Lekkas, T. D.
    GLOBAL NEST JOURNAL, 2013, 15 (04): : 504 - 512
  • [33] Data on performance of air stripping tower-PAC integrated system for removing of odor, taste, dye and organic materials from drinking water-A case study in Saqqez, Iran
    Pirsaheb, Meghdad
    Mohammadi, Jalil
    Khosravi, Touba
    Sharafi, Hooshmnd
    Moradi, Masoud
    DATA IN BRIEF, 2018, 18 : 1292 - 1297
  • [34] A polishing hybrid AER/UF membrane process for the treatment of a high DOC content surface water
    Humbert, H.
    Gallard, H.
    Croue, J. -P.
    WATER RESEARCH, 2012, 46 (04) : 1093 - 1100
  • [35] Combined effect of periodic backwashing and forward flushing on fouling mitigation in a pressurized UF membrane process for high turbid surface water treatment
    Jang, Hoseok
    Charfi, Amine
    Lee, Jaesang
    Park, Byungjoo
    Jang, Jiung
    Kim, Hyungkyung
    Kim, Jeonghwan
    DESALINATION AND WATER TREATMENT, 2018, 101 : 24 - 30
  • [36] Operational performance and cost analysis of PAC/ceramic MF for drinking water production: Exploring treatment capacity as a new indicator for performance assessment and optimization
    Campinas, Margarida
    Viegas, Rui M. C.
    Silva, Catarina
    Lucas, Helena
    Rosa, Maria Joao
    SEPARATION AND PURIFICATION TECHNOLOGY, 2021, 255
  • [37] Simultaneous coupling of fluidized granular activated carbon (GAC) and powdered activated carbon (PAC) with ultrafiltration process: A promising synergistic alternative for water treatment
    Yu, Sijia
    Wang, Jingwei
    Zhao, Zhiping
    Cai, Weiwei
    SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 282
  • [38] SURFACE WATER TREATMENT BY CUSTOM-MADE MOBILE WATER TREATMENT SYSTEM
    Ramli, Rosdianah
    Bolong, Nurmin
    JURNAL TEKNOLOGI, 2016, 78 (12): : 25 - 30
  • [39] Hydrolyzed polyacrylonitrile UF-membrane for surface and TAP water treatment: Influence on DBPs formation and removal
    Siddique, Muhammad Saboor
    Song, Qingyun
    Xiong, Xuejun
    Fareed, Hasan
    Graham, Nigel
    Yu, Wenzheng
    CHEMICAL ENGINEERING JOURNAL, 2023, 471
  • [40] Effect of the removal of DOMs on the performance of a coagulation-UF membrane system for drinking water production
    Park, PK
    Lee, CH
    Choi, SJ
    Choo, KH
    Kim, SH
    Yoon, CH
    DESALINATION, 2002, 145 (1-3) : 237 - 245