Evaluation of PAC effect in integrated PAC/UF system for surface water treatment

被引:0
|
作者
Hu, Jing-yi [1 ]
Shang, Ran [1 ]
Deng, Hui-ping [1 ]
机构
[1] Tongji Univ, Minist Educ, Key Lab Yangtze River Aquat Environm, Shanghai, Peoples R China
来源
2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010) | 2010年
关键词
PAC; PAC/UF; membrane flux; AMW; Zeta potential; ULTRAFILTRATION;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effect of powdered activated carbon (PAC) on the hybrid PAC/UF (PAC applied in combination with the ultrafiltration membrane) system was investigated in this paper. Compared to UF system, in which no PAC was added, the membrane flux was improved from 58.58% to 69.59% in terms of J/J(0) value for 200 minutes' filtration. In PAC/UF process, it is the fraction which cannot be adsorbed by PAC takes greater responsibility for membrane fouling, this fraction possesses the potential to cause more irreversible fouling, regardless of its low organic content. Analysis by technological apparatus revealed that the apparent molecular weight (AMW) of this fraction is less than 500Da or more than 10kDa, and the more than 10kDa part shows predominant, it is also easily retained on the membrane surface to produce fouling; Furthermore, this fraction exhibits almost positive Zeta potential, and can be preferentially absorbed by the negative membrane surface, so as to cause the relatively severe flux decline.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Evaluation of PAC behavior and fouling formation in an integrated PAC-UF membrane for surface water treatment
    Oh, Heekyong
    Yu, Myongjin
    Takizawa, Satoshi
    Ohgaki, Shinichiro
    DESALINATION, 2006, 192 (1-3) : 54 - 62
  • [2] PAC-UF Process Improving Surface Water Treatment: PAC Effects and Membrane Fouling Mechanism
    Li, Tian
    Yu, Hongjian
    Tian, Jing
    Liu, Junxia
    Yuan, Tonghao
    Xiao, Shaoze
    Chu, Huaqiang
    Dong, Bingzhi
    MEMBRANES, 2022, 12 (05)
  • [3] Identification of Bacterial Populations in Integrated PAC/UF System for Ammonia Nitrogen Removal in Drinking Water Treatment
    Zhang, Fulin
    Shi, Jun
    He, Yinnan
    Deng, Huiping
    JOURNAL OF PURE AND APPLIED MICROBIOLOGY, 2013, 7 (02): : 1339 - 1343
  • [4] Effect of raw water and sedimentation effluent on fouling control of PAC/UF integrated process
    Liu, Yongwang
    Li, Xing
    Yang, Yanling
    An, Dongzi
    Ren, Jiawei
    Zhou, Zhiwei
    Jia, Ruibao
    Song, Wuchang
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2014, 46 (02): : 98 - 103
  • [5] Removal of organic matter from water by PAC/UF system
    Tomaszewska, M
    Mozia, S
    WATER RESEARCH, 2002, 36 (16) : 4137 - 4143
  • [6] Influence of PAC properties on membrane performance in a PAC-UF hybrid system
    Saravia, F.
    Zwiener, C.
    Frimmel, F. H.
    WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2012, 12 (04): : 496 - 503
  • [7] Using PAC-UF to treat a low-quality surface water
    Jack, AM
    Clark, MM
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1998, 90 (11): : 83 - 95
  • [8] EVALUATION OF THE PAC SYSTEM
    Kafadarova, N.
    Stoyanova-Petrova, S.
    Mileva, N.
    INTED2014: 8TH INTERNATIONAL TECHNOLOGY, EDUCATION AND DEVELOPMENT CONFERENCE, 2014, : 4083 - 4086
  • [9] Effect of coagulation and PAC pretreatment on the fouling of MF and UF
    Nie, L.
    Chu, H. Q.
    Dong, B. Z.
    Liu, Z.
    WATER PRACTICE AND TECHNOLOGY, 2010, 5 (02):
  • [10] Chemically induced alteration in PAC characteristics and its influences on PAC/UF water treatment: Implications for on-line membrane cleaning with NaClO
    Gao, Zeyuan
    Zhao, Zhi-Ping
    Cai, Weiwei
    SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 294