Description of Gas-Phase Ion/Neutral Interactions in Differential Ion Mobility Spectrometry: CV Prediction Using Calibration Runs

被引:18
作者
Auerbach, David [1 ]
Aspenleiter, Julia [1 ]
Volmer, Dietrich A. [1 ]
机构
[1] Univ Saarland, Inst Bioanalyt Chem, D-66123 Saarbrucken, Germany
关键词
Differential ion mobility spectrometry; Gas phase modifier; Ion/neutral interactions; Compensation voltage; Prediction; ATMOSPHERIC-PRESSURE; FIELD-DEPENDENCE; SEPARATION PROCESS; RAPID ANALYSIS; IONIZATION; PEPTIDES; VISCOSITIES; METABOLITES; DENSITIES; ISOMERS;
D O I
10.1007/s13361-014-0934-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Differential ion mobility spectrometry (DMS) coupled to mass spectrometry is increasingly used in both quantitative analyses of biological samples and as a means of removing background interferences for enhanced selectivity and improved quality of mass spectra. However, DMS separation efficiency using dry inert gases often lacks the required selectivity to achieve baseline separation. Polar gas-phase modifiers such as alcohols are therefore frequently employed to improve selectivity via clustering/declustering processes. The choice of an optimal modifier currently relies on trial and error experiments, making method development a tedious activity. It was the goal of this study to establish a means of CV prediction for compounds using a homologous series of alcohols as gas-phase modifiers. This prediction was based on linear regression of compensation voltages of two calibration runs for the alcohols with the lowest and the highest molecular weights and readily available descriptors such as proton affinity and gas phase acidity of the modifier molecules. All experiments were performed on a commercial quadrupole linear ion trap mass spectrometer equipped with a DMS device between electrospray ionization source and entrance quadrupole lens. We evaluated our approach using a homologous series of 4-alkylbenzoic acids and a selection of 23 small molecules of high chemical diversity. Predicted CV values typically deviated from the experimentally determined values by less than 0.5 V. Several test compounds changed their ion mobility behavior for the investigated gas phase modifiers (e.g., from type B to type A) and thus could thus not be evaluated.
引用
收藏
页码:1610 / 1621
页数:12
相关论文
共 60 条
  • [1] Application of the Mason-Schamp Equation and Ion Mobility Mass Spectrometry To Identify Structurally Related Compounds in Crude Oil
    Ahmed, Arif
    Cho, Yun Ju
    No, Myoung-han
    Koh, Jaesuk
    Tomczyk, Nicholas
    Giles, Kevin
    Yoo, Jong Shin
    Kim, Sunghwan
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (01) : 77 - 83
  • [2] Separation of leucine and isoleucine by electrospray ionization-high field asymmetric waveform ion mobility spectrometry-mass spectrometry
    Barnett, DA
    Ells, B
    Guevremont, R
    Purves, RW
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (12) : 1279 - 1284
  • [3] GAS-PHASE ION-MOLECULE ASSOCIATION REACTIONS - STATISTICAL PHASE-SPACE THEORY APPROACH
    BASS, L
    CHESNAVICH, WJ
    BOWERS, MT
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1979, 101 (19) : 5493 - 5502
  • [4] Multi-Component Ion Modifiers and Arcing Suppressants to Enhance Differential Mobility Spectrometry for Separation of Peptides and Drug Molecules
    Blagojevic, Voislav
    Koyanagi, Gregory K.
    Bohme, Diethard K.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (03) : 490 - 497
  • [5] Differential mobility spectrometry of isomeric protonated dipeptides: Modifier and field effects on ion mobility and stability
    Blagojevic V.
    Chramow A.
    Schneider B.B.
    Covey T.R.
    Bohme D.K.
    [J]. Analytical Chemistry, 2011, 83 (09) : 3470 - 3476
  • [6] Time-of-flight ion mobility spectrometry and differential mobility spectrometry: A comparative study of their efficiency in the analysis of halogenated compounds
    Borsdorf, H.
    Nazarov, E. G.
    Miller, R. A.
    [J]. TALANTA, 2007, 71 (04) : 1804 - 1812
  • [7] Atmospheric-pressure ionization studies and field dependence of ion mobilities of isomeric hydrocarbons using a miniature differential mobility spectrometer
    Borsdorf, H.
    Nazarov, E. G.
    Miller, R. A.
    [J]. ANALYTICA CHIMICA ACTA, 2006, 575 (01) : 76 - 88
  • [8] Temperature dependence of ion mobility signals of halogenated compounds
    Borsdorf, Helko
    Mayer, Thomas
    [J]. TALANTA, 2012, 101 : 17 - 23
  • [9] Recent Developments in Ion Mobility Spectrometry
    Borsdorf, Helko
    Mayer, Thomas
    Zarejousheghani, Mashaalah
    Eiceman, Gary A.
    [J]. APPLIED SPECTROSCOPY REVIEWS, 2011, 46 (06) : 472 - 521
  • [10] Electric field dependence of ion mobilities of aromatic compounds with different ionic mass and different functional groups
    Borsdorf, Helko
    Mayer, Thomas
    [J]. INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2010, 13 (3-4) : 103 - 108