Dielectric and Physico-chemical Properties of Epoxy-Mica Insulation During Thermoelectric Aging

被引:26
作者
Castro, L. C. [1 ]
Oslinger, J. L. [1 ]
Taylor, N. [2 ]
Wahlander, M. [3 ]
机构
[1] Univ Valle, Sch Elect & Elect Engn, Cali, Colombia
[2] KTH Royal Inst Technol, Sch Elect Engn, S-10044 Stockholm, Sweden
[3] KTH Royal Inst Technol, Dept Fibre & Polymer Technol, Sch Chem Sci & Engn, S-10044 Stockholm, Sweden
关键词
Rotating machine insulation testing; capacitance measurement; loss measurement; infrared spectroscopy; calorimetry; DEGRADATION; RESIN; POLYMER; VOLTAGE;
D O I
10.1109/TDEI.2015.005270
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Three stator bars were subjected to 1142 hours of thermoelectric aging. At intervals during this time, the aging of the insulation was investigated by capacitance (C) and dissipation factor (DF) measurements and by the physicochemical techniques of infrared spectroscopy (FTIR) and Differential Scanning Calorimetry (DSC). Results indicated different degradation paths under discharge conditions, where the volume of voids within the insulation played a major role. Postcuring reactions were predominant during the first aging cycles. Such reactions were detected as reductions in capacitance and dissipation factor parameters, as a depletion of the chemical group epoxide at the absorption band 909 cm(-1) as measured by FTIR, and as an increase of the glass transition temperature (T-g) of the epoxy resin. Since the postcuring reactions occur globally in the insulation, they were detected by both dielectric and physicochemical techniques. With the advance of the aging program the epoxy resin underwent structural changes, seen as modifications of functional groups CH2, CH3 and C=O. The air atmosphere where partial discharges occurred also promoted the formation of reactive species. When the air volume was high enough, the findings of FTIR measurements suggested a local degradation mechanism of mica involving cation exchange reactions between partial discharge byproducts and potassium layers in the mica.
引用
收藏
页码:3107 / 3117
页数:11
相关论文
共 28 条
[1]   Infrared spectroscopy of micas [J].
Beran, A .
MICAS: CRYSTAL CHEMISTRY AND METAMORPHIC PETROLOGY, 2002, 46 :351-369
[2]  
Boucher V., 2008, 2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, P83, DOI 10.1109/CEIDP.2008.4772842
[3]   Mechanical and Dielectric Properties of Glass-Mica-Epoxy Composites along Accelerated Thermo-Oxidative Aging. [J].
Boucher, V. ;
Rain, P. ;
Teissedre, G. ;
Schlupp, P. .
2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, :162-+
[4]   Behavior of Machine Insulation Systems Subjected to Accelerated Thermal Aging Test [J].
Farahani, M. ;
Gockenbach, E. ;
Borsi, H. ;
Schaefer, K. ;
Kaufhold, M. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (05) :1364-1372
[5]   Study of capacitance and dissipation factor tip-up to evaluate the condition of insulating systems for high voltage rotating machines [J].
Farahani, Mohsen ;
Borsi, Hossein ;
Gockenbach, Ernst .
ELECTRICAL ENGINEERING, 2007, 89 (04) :263-270
[6]  
Hale A.:., 2002, Handbook of Thermal Analysis and Calorimetry, V3, P295, DOI [DOI 10.1002/pts.621, 10.1016/S1573-4374(02)80012-7, DOI 10.1016/S1573-4374(02)80012-7]
[7]   Degradation of Epoxy in Stator Insulation in Service 23 Years for A Large Generator [J].
Hao, Y. P. ;
Wang, X. L. ;
Xie, H. K. .
2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, :314-+
[8]  
Hao Yan-peng, 2008, Proceedings of the CSEE, V28, P15
[9]   Degradation of epoxy resin by partial discharges [J].
Hepburn, DM ;
Kemp, IJ ;
Shields, AJ ;
Cooper, J .
IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2000, 147 (03) :97-104
[10]  
HSU C.P. S., 1997, HDB INSTRUMENTAL TEC