Design of a post linac for an energy upgrade of a heavy-ion injector

被引:1
作者
Iwata, Y. [1 ]
Noda, K. [1 ]
机构
[1] Natl Inst Radiol Sci, Dept Accelerator & Med Phys, Inage Ku, Chiba 2638555, Japan
关键词
Heavy ion linac; RFQ; Interdigital H-mode (IH) structure; Alternating-Phase-Focusing (APF); Medical accelerators; Heavy ion therapy; MEDICAL ACCELERATORS; FACILITY; THERAPY;
D O I
10.1016/j.nimb.2013.09.041
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A post linac is being designed for an energy upgrade of a heavy-ion injector. This post linac is to be installed downstream of the formerly developed compact injector, consisting of an Electron-Cyclotron-Resonance Ion-Source (ECRIS), the Radio-Frequency-Quadrupole (RFQ) linac and the Alternating-Phase-Focused Interdigital H-mode Drift-Tube-Linac (APF IH-DTL). It is aimed to increase the output energy of a heavy-ion injector. Carbon ions are initially accelerated with the compact injector to 4 MeV/u, and further accelerated with the post linac up to 8 MeV/u. The three linacs have the same operating frequency of 200 MHz. For beam focusing of the post linac, the APF method is used. Iterative simulations of beam dynamics were performed to determine the optimum array of synchronous phases in each gap. The results of the simulations provided that the calculated efficiency of beam transmission through the post linac is as high as 98.4%. The total length of this APF post linac is estimated to be approximately 3 m. A design overview of the injector system including the post linac is presented. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 9 条
[1]  
GOOD ML, 1953, PHYS REV, V92, P538
[2]   Performance of a compact injector for heavy-ion medical accelerators [J].
Iwata, Y. ;
Yamada, S. ;
Murakami, T. ;
Fujimoto, T. ;
Fujisawa, T. ;
Ogawa, H. ;
Miyahara, N. ;
Yamamoto, K. ;
Hojo, S. ;
Sakamoto, Y. ;
Muramatsu, M. ;
Takeuchi, T. ;
Mitsumoto, T. ;
Tsutsui, H. ;
Watanabe, T. ;
Ueda, T. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (03) :1007-1021
[3]   Alternating-phase-focused IH-DTL for an injector of heavy-ion medical accelerators [J].
Iwata, Y. ;
Yamada, S. ;
Murakami, T. ;
Fujimoto, T. ;
Fujisawa, T. ;
Ogawa, H. ;
Miyahara, N. ;
Yamamoto, K. ;
Hojo, S. ;
Sakamoto, Y. ;
Muramatsu, M. ;
Takeuchi, T. ;
Mitsumoto, T. ;
Tsutsui, H. ;
Watanabe, T. ;
Ueda, T. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (03) :685-696
[4]  
KILPATRICK WD, 1957, REV SCI INSTRUM, V28, P825
[5]   Design of carbon therapy facility based on 10 years experience at HIMAC [J].
Noda, K. ;
Furukawa, T. ;
Iwata, Y. ;
Kanai, T. ;
Kanazawa, M. ;
Kanematsu, N. ;
Kitagawa, A. ;
Komori, M. ;
Minohara, S. ;
Murakami, T. ;
Muramatsu, M. ;
Sato, S. ;
Sato, Y. ;
Shibuya, S. ;
Torikoshi, M. ;
Yamada, S. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 562 (02) :1038-1041
[6]   New accelerator facility for carbon-ion cancer-therapy [J].
Noda, Koji ;
Furukawa, Takuji ;
Fujisawa, Takashi ;
Iwata, Yoshiyuki ;
Kanai, Tatsuaki ;
Kanazawa, Mitsutaka ;
Kitagawa, Atsushi ;
Komori, Masataka ;
Minohara, Shinichi ;
Murakami, Takeshi ;
Muramatsu, Masayuki ;
Sato, Shinji ;
Takei, Yuka ;
Tashiro, Mutsumi ;
Torikoshi, Masarni ;
Yamada, Satoru ;
Yusa, Ken .
JOURNAL OF RADIATION RESEARCH, 2007, 48 (A43-A54) :A43-A54
[7]  
Ohno Tatsuya, 2011, Cancers (Basel), V3, P4046, DOI 10.3390/cancers3044046
[8]  
Schnizer B., 1971, Particle Accelerators, V2, P141
[9]   EQUILIBRIUM CHARGE FRACTIONS OF IONS OF Z=4-92 EMERGING FROM A CARBON FOIL [J].
SHIMA, K ;
KUNO, N ;
YAMANOUCHI, M ;
TAWARA, H .
ATOMIC DATA AND NUCLEAR DATA TABLES, 1992, 51 (02) :173-241