Determination of tranexamic acid in cosmetic products by high-performance liquid chromatography coupled with barrel plating nickel electrode

被引:13
|
作者
Shih, Ying [2 ]
Wu, Kuan-Lin [1 ]
Sue, Jun-Wei [1 ]
Kumar, Annamalai Senthil [3 ]
Zen, Jyh-Myng [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
[2] Hung Kuang Univ, Dept Appl Cosmetol, Taichung 433, Taiwan
[3] Vellore Inst Technol Univ, Dept Chem, Vellore 632014, Tamil Nadu, India
关键词
Tranexamic acid; Disposable; Barrel plating nickel electrode; Cosmetics;
D O I
10.1016/j.jpba.2008.09.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tranexamic acid (TA) is an important reagent in cosmetic skin-whitening formulation and a drug for the inhibition of plasminogen to plasmin in blood. Since there is no chromophore in tranexamic acid molecule to enable direct analysis by UV-visible absorption spectrophotometry, derivatization is thus required by excluding use of UV or fluorescence detection. We report here a relatively simple electrochemical TA detection method by using a barrel plating nickel electrode. Chromatographic separation was performed on a Hamilton PRP-X100 anion-exchange column (150mm x 4.1 mm i.d., 10 mu m particle size) with a (85:15, v/v) mixture of 0.1 mol 1(-1) NaOH and acetonitrile as mobile phase and pumped at a flow rate of 0.9 ml min(-1). By detecting at +0.55 V vs. Ag/AgCl, the calibration plot was linear in the concentration window of 3-1000 ppm with regression coefficient and detection limit (S/N=3) of 0.9993 and 0.13 ppm (0.84 mu mol 1(-1)), respectively. Successive injections (n= 10) of 50 ppm tranexamic acid showed a R.S.D. value of only 0.3% indicating good reproducibility of the proposed system. The method was successfuliy applied to the analysis of the content of tranexamic acid in cosmetic products and proved to be suitable for rapid and reliable quality control. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1446 / 1450
页数:5
相关论文
共 50 条
  • [41] Simultaneous determination of 22 sunscreen agents in cosmetics by ultra -high-performance liquid chromatography using diode array detector
    Zhang Keming
    Deng Ming
    Su Yuanyuan
    Xie Dong
    Xu Youcheng
    Liu Xianghong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (04) : 415 - 423
  • [42] Simultaneous Determination of Cysteamine and Cystamine in Cosmetics by Ion-Pairing Reversed-Phase High-Performance Liquid Chromatography
    Kim, Yejin
    Na, Dong Hee
    TOXICOLOGICAL RESEARCH, 2019, 35 (02) : 161 - 165
  • [43] Simultaneous Determination of Cysteamine and Cystamine in Cosmetics by Ion-Pairing Reversed-Phase High-Performance Liquid Chromatography
    Yejin Kim
    Dong Hee Na
    Toxicological Research, 2019, 35 : 161 - 165
  • [44] Ultrasound- and Vortex-Assisted Dispersive Liquid-Liquid Microextraction of Parabens from Personal Care Products and Urine, Followed by High-Performance Liquid Chromatography
    Yilmaz, Pelin Koseoglu
    Kolak, Ufuk
    TURKISH JOURNAL OF PHARMACEUTICAL SCIENCES, 2023, 20 (05) : 328 - 334
  • [45] High-performance liquid chromatography-diode array and electrospray-mass spectrometry analysis of non-allowed substances in cosmetic products for preventing hair loss and other hormone-dependent skin diseases
    De Orsi, Daniela
    Pellegrini, Manuela
    Pichini, Simona
    Mattioli, Donatella
    Marchei, Emilia
    Gagliardi, Luigi
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (03) : 641 - 648
  • [46] Determination of six ultraviolet filters in cosmetics by high performance liquid chromatography coupled with solid-phase extraction based on graphene sponge
    Wang Xuemei
    Wang Juan
    Du Tongtong
    Ma Xiaomin
    Lu Xianquan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2018, 36 (03) : 190 - 194
  • [47] Determination of polymer additives in foods and drinks packed with plastic by amino group modified magnetic mesoporous silica microspheres coupled with high performance liquid chromatography
    Zhao, Xiaoyan
    Liu, Xuerui
    Wang, Juanqiang
    Liu, Yuanyuan
    Zhang, Taoyi
    Chen, Jing
    Li, Quan
    Wei, Yun
    Xi, Xingjun
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2021, 44 (3-4) : 244 - 254
  • [48] Determination of parabens in cosmetic products by solid-phase microextraction of poly(ethylene glycol) diacrylate thin film on fibers and ultra high-speed liquid chromatography with diode array detector
    Fei, Ting
    Li, Haifang
    Ding, Mingyu
    Ito, Masahito
    Lin, Jin-Ming
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (13) : 1599 - 1606
  • [49] Determination of Human Epidermal Growth Factor in Cosmetics by Solid Phase Extraction (SPE) with High-performance Liquid Chromatography - Tandem Mass Spectrometry (HPLC-MS/MS)
    Yang, Ming
    Yi, Jun
    Wei, Cong
    Lu, Yuepeng
    Yang, Yong
    Yang, Zong
    Zhao, Liuqing
    Jiang, Xiaoming
    Tu, Fengqin
    Chen, Dan
    ANALYTICAL LETTERS, 2024, 57 (11) : 1704 - 1714
  • [50] One-step membrane protected micro-solid-phase extraction and derivatization coupling to high-performance liquid chromatography for selective determination of aliphatic aldehydes in cosmetics and food
    Xia, Ling
    Du, Yuanqi
    Xiao, Xiaohua
    Li, Gongke
    TALANTA, 2019, 202 : 580 - 590