Repeatability of standard transthoracic echocardiographic measurements in horses

被引:26
作者
Kriz, NG [1 ]
Rose, RJ [1 ]
机构
[1] Univ Sydney, Dept Vet Clin Sci, Sydney, NSW 2006, Australia
关键词
D O I
10.1111/j.1751-0813.2002.tb14790.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objectives To assess the repeatability of commonly employed transthoracic echocardiographic measurements in standing horses. Design Thirteen healthy 3- to 4-year-old fit Standardbred geldings with a mean weight of 411 (SEM +/- 10) kg were studied. The horses' environment, feeding and management regimens were standardised. All measurements were performed by the same investigator at the same time every day for three consecutive days. Procedures Standard transthoracic measurements were made on all horses. Each measurement was performed over three consecutive cardiac cycles on 1 day and all measurements were performed over 3 consecutive days. Summary statistics of each day were then compared using an analysis of variance with times as a repeated measures factor. Statistical significance was set at P < 0.05. Results Many of the standard echocardiographic measurements used to derive quantitative and functional information about the equine heart have a low intra-observer variability. Conclusions Standard transthoracic echocardiographic measurements have a low enough intra-observer variability to warrant their use for clinical and experimental studies.
引用
收藏
页码:362 / 370
页数:9
相关论文
共 28 条
  • [1] Blissitt K J, 1995, Equine Vet J Suppl, P38
  • [2] BONAGURA JD, 1995, EQUINE VET J S, V19, P5
  • [3] ACCURACY AND REPRODUCIBILITY OF CLINICALLY ACQUIRED TWO-DIMENSIONAL ECHOCARDIOGRAPHIC MASS MEASUREMENTS
    BYRD, BF
    FINKBEINER, W
    BOUCHARD, A
    SILVERMAN, NH
    SCHILLER, NB
    [J]. AMERICAN HEART JOURNAL, 1989, 118 (01) : 133 - 137
  • [4] METHOD OF SELECTIVE AND NON-SELECTIVE ANGIOCARDIOGRAPHY FOR THE HORSE
    CARLSTEN, J
    KVART, C
    JEFFCOTT, LB
    [J]. EQUINE VETERINARY JOURNAL, 1984, 16 (01) : 47 - 52
  • [5] SYSTEMATIC CORRELATION OF CARDIAC CHAMBER SIZE AND VENTRICULAR PERFORMANCE DETERMINED WITH ECHOCARDIOGRAPHY AND ALTERATIONS IN HEART-RATE IN NORMAL PERSONS
    DEMARIA, AN
    NEUMANN, A
    SCHUBART, PJ
    LEE, G
    MASON, DT
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1979, 43 (01) : 1 - 9
  • [6] SOURCES OF VARIABILITY IN ECHOCARDIOGRAPHIC MEASUREMENTS
    FELNER, JM
    BLUMENSTEIN, BA
    SCHLANT, RC
    CARTER, AD
    ALIMURUNG, BN
    JOHNSON, MJ
    SHERMAN, SW
    KLICPERA, MW
    KUTNER, MH
    DRUCKER, LW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (05) : 995 - 1004
  • [7] REPRODUCIBILITY OF DOPPLER AORTIC BLOOD-FLOW MEASUREMENTS - STUDIES ON INTRAOBSERVER, INTEROBSERVER AND DAY-TO-DAY VARIABILITY IN NORMAL SUBJECTS
    GARDIN, JM
    DABESTANI, A
    MATIN, K
    ALLFIE, A
    RUSSELL, D
    HENRY, WL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 54 (08) : 1092 - 1098
  • [8] Goldberg S.J., 1988, DOPPLER ECHOCARDIOGR, V2nd
  • [9] LAPIDO GOA, 1980, BRIT HEART J, V44, P284
  • [10] LESCURE F, 1984, REV MED VET-TOULOUSE, V135, P405