Implementation of concurrent red blood cell and platelet collection by apheresis in a university haemapheresis unit

被引:12
作者
Moog, R [1 ]
机构
[1] Univ Clin Essen, Inst Traunsfus Med, D-45122 Essen, Germany
关键词
automated RBC collection; blood supply; cost-effectiveness; multicomponent collection; side effects;
D O I
10.1111/j.0958-7578.2004.00490.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The present study analyses the number of concurrently collected red blood cell (RBC) units in plateletpheresis donors and the reasons why donors were deferred from multicomponent collection. Donors undergoing concurrent collection of RBCs and platelets (PLTs) were retrospectively evaluated for haemoglobin values and the reasons for deferral over a period of 1 year. A total of 404 RBC units were concurrently collected with PLTs. An average of 1.8 RBC units per year was collected from each donor. The baseline haemoglobin values were almost equal for the RBC donations. An RBC unit was not collected in 190 aphereses. Most frequent reasons for the noncollection of an RBC product were a donation interval of less than 3 months (20.5%), haematoma and blood flow problems (18.9%) and low pre-haemoglobin values (17.4%). Donor eligibility has to be taken into account to optimize concurrent RBC collection in plateletpheresis.
引用
收藏
页码:145 / 150
页数:6
相关论文
共 24 条
[1]   Plateletpheresis efficiency: a comparison of the Spectra LRS and AMICUS separators [J].
Benjamin, RJ ;
Rojas, P ;
Christmas, S ;
Neal, J ;
Broughton, S ;
Burgio, C ;
Barrett, B ;
Churchill, WH .
TRANSFUSION, 1999, 39 (08) :895-899
[2]  
Burkhardt T, 1998, INFUSIONSTHERAPIE, V25, P376
[3]   Evaluation of an automated system for the collection of packed RBCs, platelets, and plasma [J].
Elfath, MD ;
Whitley, P ;
Jacobson, MS ;
Cranfill-Hupp, K ;
Kemp, DM ;
McNeil, D ;
Sawyer, S ;
Bell-Dize, S ;
Gorlin, JB ;
Kevy, SV ;
McAteer, MJ .
TRANSFUSION, 2000, 40 (10) :1214-1222
[4]   Prolonged iron depletion after allogeneic X-unit RBC apheresis [J].
Högler, W ;
Mayer, W ;
Messmer, C ;
Eibl, G ;
Innhofer, P ;
Schönitzer, D ;
Nussbaumer, W .
TRANSFUSION, 2001, 41 (05) :602-605
[5]  
Holme S, 1998, VOX SANG, V75, P212, DOI 10.1046/j.1423-0410.1998.7530212.x
[6]   Leukodepletion of platelet concentrates and plasma collected with Haemoneties® MCS+ apheresis system.: Experience of EFS-Alsace [J].
Kientz, D ;
Laforêt, M ;
Isola, H ;
Cazenave, JP .
TRANSFUSION AND APHERESIS SCIENCE, 2001, 25 (01) :55-59
[7]   A new apheresis procedure for the preparation of high-quality red cells and plasma [J].
Knutson, F ;
Rider, J ;
Franck, V ;
Joie, M ;
Högman, CF ;
Pamphilon, D .
TRANSFUSION, 1999, 39 (06) :565-571
[8]  
Kurahashi M, 1999, Ther Apher, V3, P307, DOI 10.1046/j.1526-0968.1999.00210.x
[9]   IMPROVED RED-CELL QUALITY AFTER ERYTHROPLASMAPHERESIS WITH MCS-3P [J].
MATTHES, G ;
TOFOTE, U ;
KRAUSE, KP ;
PAWLOW, I ;
KUCERA, W ;
LERCHE, D .
JOURNAL OF CLINICAL APHERESIS, 1994, 9 (03) :183-188
[10]  
Matthes G A, 1997, Ther Apher, V1, P22, DOI 10.1111/j.1744-9987.1997.tb00008.x