摘要
Background: The suction sockets that are commonly prescribed for transtibial amputees are believed to provide a better suspension than the pin/lock systems. Nevertheless, their effect on amputees' gait performance has not yet been fully investigated. The main intention of this study was to understand the potential effects of the Seal-in (suction) and the Dermo (pin/lock) suspension systems on amputees' gait performance. Methodology/Principal Findings: Ten unilateral transtibial amputees participated in this prospective study, and two prostheses were fabricated for each of them. A three-dimensional motion analysis system was used to evaluate the temporal-spatial, kinematics and kinetics variables during normal walking. We also asked the participants to complete some part of Prosthesis Evaluation Questionnaire (PEQ) regarding their satisfaction and problems with both systems. The results revealed that there was more symmetry in temporal-spatial parameters between the prosthetic and sound limbs using the suction system. However, the difference between two systems was not significant (p<0.05). Evaluation of kinetic data and the subjects' feedback showed that the participants had more confidence using the suction socket and the sockets were more fit for walking. Nevertheless, the participants had more complaints with this system due to the difficulty in donning and doffing. Conclusion: It can be concluded that even though the suction socket could create better suspension, fit, and gait performance, overall satisfaction was higher with the pin/lock system due to easy donning and doffing of the prosthesis.
引用
收藏
页数:9
相关论文
共 5 条
  • [1] Vacuum level effects on gait characteristics for unilateral transtibial amputees with elevated vacuum suspension
    Xu, Hang
    Greenland, Kasey
    Bloswick, Donald
    Zhao, Jie
    Merryweather, Andrew
    CLINICAL BIOMECHANICS, 2017, 43 : 95 - 101
  • [2] A comparison between the suction suspension system and the hypobaric Iceross Seal-In® X5 in transtibial amputees
    Brunelli, Stefano
    Delussu, Anna Sofia
    Paradisi, Francesco
    Pellegrini, Roberto
    Traballesi, Marco
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2013, 37 (06) : 436 - 444
  • [3] Vacuum level effects on knee contact force for unilateral transtibial amputees with elevated vacuum suspension
    Xu, Hang
    Greenland, Kasey
    Bloswick, Donald
    Zhao, Jie
    Merryweather, Andrew
    JOURNAL OF BIOMECHANICS, 2017, 57 : 110 - 116
  • [4] Effects of the unity vacuum suspension system on transtibial gait for simulated non-level surfaces
    Thibault, Gabrielle
    Gholizadeh, Hossein
    Sinitski, Emily
    Baddour, Natalie
    Lemaire, Edward D.
    PLOS ONE, 2018, 13 (06):
  • [5] Effectiveness of elevated vacuum and suction prosthetic suspension systems in managing daily residual limb fluid volume change in people with transtibial amputation
    Youngblood, Robert T.
    Brzostowski, Jacob T.
    Hafner, Brian J.
    Czerniecki, Joseph M.
    Allyn, Katheryn J.
    Foster, Richard L.
    Sanders, Joan E.
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2020, 44 (03) : 155 - 163