Chemometrics-assisted simultaneous voltammetric determination of ascorbic acid, uric acid, dopamine and nitrite: Application of non-bilinear voltammetric data for exploiting first-order advantage

被引:44
作者
Gholivand, Mohammad-Bagher [1 ]
Jalalvand, Ali R. [1 ,2 ]
Goicoechea, Hector C. [2 ]
Skov, Thomas [3 ]
机构
[1] Razi Univ, Fac Chem, Kermanshah 671496734, Iran
[2] Univ Nacl Litoral, Catedra Quim Analit 1, Lab Desarrollo Analit & Quimiometria LADAQ, Santa Fe, Argentina
[3] Univ Copenhagen, Fac Life Sci, Dept Food Sci, Qual & Technol Grp, DK-1958 Frederiksberg, Denmark
关键词
Ascorbic acid; Uric acid; Dopamine; Nitrite; Simultaneous determination; Linear and non-linear multivariate calibration models; PARTIAL LEAST-SQUARES; RADIAL BASIS FUNCTIONS; VARIABLE SELECTION; REGRESSION; OXIDE;
D O I
10.1016/j.talanta.2013.11.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the first time, several multivariate calibration (MVC) models including partial least squares-1 (PLS-1), continuum power regression (CPR), multiple linear regression-successive projections algorithm (MLR-SPA), robust continuum regression (RCR), partial robust M-regression (PRM), polynomial-PLS (PLY-PLS), spline-PLS (SPL-PLS), radial basis function-PLS (RBF-PLS), least squares-support vector machines (LS-SVM), wavelet transform-artificial neural network (WT-ANN), discrete wavelet transform-ANN (DWT-ANN), and back propagation-ANN (BP-ANN) have been constructed on the basis of non-bilinear first order square wave voltammetric (SWV) data for the simultaneous determination of ascorbic acid (AA), uric acid (UA), dopamine (DP) and nitrite (NT) at a glassy carbon electrode (GCE) to identify which technique offers the best predictions. The compositions of the calibration mixtures were selected according to a simplex lattice design (SLD) and validated with an external set of analytes' mixtures. An asymmetric least squares splines regression (AsLSSR) algorithm was applied for correcting the baselines. A correlation optimized warping (COW) algorithm was used to data alignment and lack of bilinearity was tackled by potential shift correction. The effects of several pre-processing techniques such as genetic algorithm (GA), orthogonal signal correction (OSC), mean centering (MC), robust median centering (RMC), wavelet denoising (WD), and Savitsky-Golay smoothing (SGS) on the predictive ability of the mentioned MVC models were examined. The best preprocessing technique was found for each model. According to the results obtained, the RBF-PLS was recommended to simultaneously assay the concentrations of AA, UA, DP and NT in human serum samples. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:553 / 563
页数:11
相关论文
共 42 条
[1]   Potential shift correction in multivariate curve resolution of voltammetric data.: General formulation and application to some experimental systems [J].
Alberich, Aristides ;
Diaz-Cruz, Jose Manuel ;
Arino, Cristina ;
Esteban, Miquel .
ANALYST, 2008, 133 (01) :112-125
[2]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[3]  
[Anonymous], 1975, International Perspectives on Mathematical and Statistical Modeling, DOI DOI 10.1016/B978-0-12-103950-9.50017-4
[4]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[5]   The successive projections algorithm for variable selection in spectroscopic multicomponent analysis [J].
Araújo, MCU ;
Saldanha, TCB ;
Galvao, RKH ;
Yoneyama, T ;
Chame, HC ;
Visani, V .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2001, 57 (02) :65-73
[6]   Wavelet neural network (WNN) approach for calibration model building based on gasoline near infrared (NIR) spectra [J].
Balabin, Roman M. ;
Safieva, Ravilya Z. ;
Lomakina, Ekaterina I. .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2008, 93 (01) :58-62
[7]   Comparison of linear and nonlinear calibration models based on near infrared (NIR) spectroscopy data for gasoline properties prediction [J].
Balabin, Roman M. ;
Safieva, Ravilya Z. ;
Lomakina, Ekaterma I. .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2007, 88 (02) :183-188
[8]   A chemometric analysis of dual pulse staircase voltammograms obtained in mixtures of ethanol, fructose and glucose [J].
Bessant, C ;
Saini, S .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 489 (1-2) :76-83
[9]   Comparison of multivariate calibration techniques applied to experimental NIR data sets [J].
Centner, V ;
Verdú-Andrés, J ;
Walczak, B ;
Jouan-Rimbaud, D ;
Despagne, F ;
Pasti, L ;
Poppi, R ;
Massart, DL ;
de Noord, OE .
APPLIED SPECTROSCOPY, 2000, 54 (04) :608-623
[10]   EXTENDING THE RELATIONSHIP BETWEEN RIDGE-REGRESSION AND CONTINUUM REGRESSION [J].
DEJONG, S ;
FAREBROTHER, RW .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1994, 25 (02) :179-181