Radiation Dose Reduction in the Cardiac Catheterization Laboratory Utilizing a Novel Protocol

被引:58
|
作者
Wassef, Anthony W. A. [1 ]
Hiebert, Brett [1 ]
Ravandi, Amir [1 ]
Ducas, John [1 ]
Minhas, Kunal [1 ]
Vo, Minh [1 ]
Kass, Malek [1 ]
Parmar, Gurpreet [1 ]
Hussain, Farrukh [1 ]
机构
[1] Univ Manitoba, Dept Med, Div Cardiol, Winnipeg, MB R2H 2A6, Canada
关键词
diagnostic coronary angiography; frame rate; percutaneous coronary intervention; radiation; x-ray; CARDIOLOGY; QUALITY; PATIENT; CANCER; SAFETY;
D O I
10.1016/j.jcin.2013.11.022
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study reports the results a novel radiation reduction protocol (RRP) system for coronary angiography and interventional procedures and the determinants of radiation dose. Background The cardiac catheterization laboratory is an important source of radiation and should be kept in good working order with dose-reduction and monitoring capabilities. Methods All diagnostic coronary angiograms and percutaneous coronary interventions from a single catheterization laboratory were analyzed 2 months before and after RRP implementation. The primary outcome was the relative dose reduction at the interventional reference point. Separate analyses were done for conventional 15 frames/s (FPS) and at reduced 7.5 FPS post-RRP groups. Results A total of 605 patients underwent coronary angiography (309 before RRP and 296 after RRP), with 129 (42%) and 122 (41%) undergoing percutaneous coronary interventions before and after RRP, respectively. With RRP, a 48% dose reduction (1.07 +/- 0.05 Gy vs. 0.56 +/- 0.03 Gy, p < 0.0001) was obtained, 35% with 15 FPS RRP (0.70 +/- 0.05 Gy, p < 0.0001) and 62% with 7.5 FPS RRP (0.41 +/- 0.03 Gy, p < 0.001). Similar dose reductions for diagnostic angiograms and percutaneous coronary interventions were noted. There was no change in the number of stents placed or vessels intervened on. Increased dose was associated with male sex, radial approach, increasing body mass index, cine runs, and frame rates. Using a multivariable model, a 48% relative risk with RRP (p < 0.001), 44% with 15 FPS RRP and 68% with 7.5 FPS RRP was obtained. Conclusions We demonstrate a highly significant 48.5% adjusted radiation dose reduction using a novel algorithm, which needs strong consideration among interventional cardiology practice. (C) 2014 by the American College of Cardiology Foundation
引用
收藏
页码:550 / 557
页数:8
相关论文
共 50 条
  • [41] Quality management in the cardiac catheterization laboratory
    Henien, Shady
    Aronow, Herbert D.
    Abbott, J. Dawn
    JOURNAL OF THORACIC DISEASE, 2020, 12 (04) : 1695 - 1705
  • [42] Operators' radiation exposure reduction during cardiac catheterization using a removable shield
    Arrivi, Alessio
    Pucci, G.
    Vaudo, G.
    Bier, N.
    Bock, C.
    Casavecchia, M.
    Bazzucchi, M.
    Dominici, M.
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2020, 35 (04) : 379 - 384
  • [43] Reduction in Primary Operator Radiation Dose Exposure During Coronary Angioplasty Using Radiation Absorbing Drape
    Sharma, Amit B.
    Agrawal, Richa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [44] Standardizing Radiation Dose Reporting in the Pediatric Cardiac Catheterization Laboratory-A Multicenter Study by the CCISC (Congenital Cardiovascular Interventional Study Consortium)
    Kobayashi, Daisuke
    Meadows, Jeffery
    Forbes, Thomas J.
    Moore, Phillip
    Javois, Alexander J.
    Pedra, Carlos A.
    Du, Wei
    Gruenstein, Daniel H.
    Wax, David F.
    Hill, James A.
    Graziano, Joseph N.
    Fagan, Thomas E.
    Mosquera Alvarez, Walter
    Nykanen, David G.
    Divekar, Abhay A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (05) : 785 - 793
  • [45] Minimizing scattered radiation dose in cardiac catheterization laboratory during interventional procedures using lead free drape-MILD study
    Bhat, Keshavamurthy Ganapathy
    Guleria, Vivek Singh
    Singla, Manish
    Bohra, Vijay
    Kumar, J. Ratheesh
    Bharadwaj, Prashant
    Datta, Rajat
    Hasija, Pradeep Kumar
    INDIAN HEART JOURNAL, 2022, 74 (03) : 201 - 205
  • [46] Radiation Exposure in Cardiac Catheterization Operator Behavior Matters
    Kobayashi, Taisei
    Hirshfeld, John W., Jr.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (08)
  • [47] Patient Radiation Exposure in a Modern, Large-Volume, Pediatric Cardiac Catheterization Laboratory
    Andrew C. Glatz
    Akash Patel
    Xiaowei Zhu
    Yoav Dori
    Brian D. Hanna
    Matthew J. Gillespie
    Jonathan J. Rome
    Pediatric Cardiology, 2014, 35 : 870 - 878
  • [48] Clinical feasibility and safety of a novel miniature mobile cardiac catheterization laboratory in diagnosis and treatment for coronary heart disease
    Liang Ming
    Han Yaling
    Wang Geng
    Yao Tianming
    Sun Jingyang
    Li Fei
    Xu Kai
    Wang Bin
    Li Yi
    Rong Jingjing
    Wang Xiaozeng
    CHINESE MEDICAL JOURNAL, 2014, 127 (06) : 1052 - 1056
  • [49] Radiation Dose Reduction in the Invasive Cardiovascular Laboratory Implementing a Culture and Philosophy of Radiation Safety
    Fetterly, Kenneth A.
    Mathew, Verghese
    Lennon, Ryan
    Bell, Malcolm R.
    Holmes, David R., Jr.
    Rihal, Charanjit S.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (08) : 867 - 873
  • [50] Economic implications of bivalirudin in the cardiac catheterization laboratory
    Bakhai, Ameet
    Cohen, David J.
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2006, 7 : S35 - S42