Results of endovascular repair of infrarenal aortic aneurysms using the Endurant stent graft

被引:30
|
作者
Zandvoort, Herman J. A. [1 ]
Goncalves, Frederico Bastos [2 ]
Verhagen, Hence J. M. [2 ]
Werson, Debora A. B. [3 ]
Moll, Frans L. [1 ]
de Vries, Jean-Paul P. M. [3 ]
van Herwaarden, Joost A. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Vasc Surg, NL-3508 GA Utrecht, Netherlands
[2] Erasmus MC, Dept Vasc Surg, Rotterdam, Netherlands
[3] St Antonius Hosp, Dept Vasc Surg, Nieuwegein, Netherlands
关键词
MULTICENTER; ENDOGRAFT; REGISTRY; TRIAL;
D O I
10.1016/j.jvs.2013.12.031
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Recent reports showed that the Endurant stent graft (Medtronic Cardiovascular, Santa Rosa, Calif) is safe and effective for endovascular repair of abdominal aortic aneurysms (AAAs). However, due to its relatively recent introduction, only short-term follow-up data are available. This study presents the 4-year results using this device. Methods: All clinical data, including detailed anatomic information of the first 100 consecutive patients treated with the Endurant stent graft for an infrarenal AAA in three Dutch high-volume hospitals, were prospectively collected. Computed tomography angiography was routinely performed before the procedure, <= 1 month, and at 1 year post-endovascular aneurysm repair. Thereafter, the imaging modality during yearly follow-up was individualized (duplex ultrasound imaging or computed tomography angiography). Patients were classified as within or outside the instructions for use (IFU) for analysis. Study end points were primary clinical success, overall and AAA-related mortality, and sac morphology changes and endoleak during follow-up. Estimates were obtained using Kaplan-Meier plots. Results: The study included 100 consecutive patients (88 men) with a median age of 74 years (interquartile range [IQR], 67-79 years) and median AAA diameter of 58 mm (IQR, 55-65 mm), between December 2007 and March 2009. Twenty patients (20%) were treated outside the IFU (18, outside proximal neck IFU, one outside iliac IFU, and one outside both IFUs). Median follow-up was 48 months (IQR, 36-53 months), and no patients were lost. One contained rupture was observed after 1.5 months due to graft infection. No patients had graft migration. Two type Ia endoleaks, 5 type Ib endoleaks, and 15 type II endoleaks were found. Primary clinical success was 97%, 90%, 84% and 77% at 1, 2, 3, and 4 years, respectively. Primary clinical success was comparable for patients treated within or outside IFU (P = .20), although both patients outside iliac IFU needed a secondary iliac intervention. Over time, maximum aneurysm diameter decreased >= 5 mm, remained stable, and increased >= 5 mm in 58%, 32%, and 10% of the patients, respectively. All-cause mortality was 20% at 4 years, with a 3% AAA-related mortality. Conclusions: The 4-year follow-up data of the Endurant stent graft for AAA treatment shows its use results in a low AAA-related mortality with adequate prevention of rupture or aneurysm growth. Although patients with very challenging anatomy were treated in our series, primary clinical success rates were comparable for patients treated within and outside the IFU. However, both patients outside the iliac IFU needed a secondary iliac intervention. The knowledge of the present results may aid in improving outcomes in the future.
引用
收藏
页码:1195 / 1202
页数:8
相关论文
共 50 条
  • [1] Endovascular Repair of Abdominal Aortic Aneurysms With Reverse Taper Neck Anatomy Using the Endurant Stent-Graft: Analysis of Stent-Graft Oversizing
    Mwipatayi, Bibombe P.
    Picardo, Alarick
    Wong, Jackie
    Thomas, Shannon D.
    Vijayan, Vikram
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (04) : 514 - 522
  • [2] The Endurant stent graft for endovascular aneurysm repair
    de Beaufort, Hector
    Zandvoort, Herman J.
    Moll, Frans L.
    Van Herwaarden, Joost A.
    EXPERT REVIEW OF MEDICAL DEVICES, 2014, 11 (04) : 331 - 340
  • [3] Use of the Endurant Stent Graft System for Ruptured Infrarenal Aortic Aneurysms: Short-term Experience in Nine Patients
    Koike, Yuya
    Nishimura, Jun-ichi
    Nishimaki, Hiroshi
    Hase, Soichiro
    Moriya, Nobukazu
    Oshima, Susumu
    Fujikawa, Takuya
    Sekine, Yuji
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (10) : 1462 - 1469
  • [4] Endovascular repair of ruptured abdominal aortic aneurysms with the endurant stent-graft: a combined experience from three centers
    Papazoglou, Konstantinos
    Mallios, Alexandros
    Buster, Bryan
    Antoniadis, Pavlos
    Karkos, Christos
    Staramos, Dimitris
    Dervisis, Konstantinos
    Messiner, Ryan
    Blebea, John
    JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 58 (05) : 643 - 649
  • [5] Endovascular Repair of Ruptured Abdominal Aortic Aneurysms Using the Endurant™ Endograft
    Nana, Petroula
    Volakakis, George
    Spanos, Konstantinos
    Kouvelos, George
    Bareka, Metaxia
    Arnaoutoglou, Eleni
    Giannoukas, Athanasios
    Matsagkas, Miltiadis
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (17)
  • [6] Stent graft types for endovascular repair of abdominal aortic aneurysms
    Duffy, James M. N.
    Rolph, Rachel
    Waltham, Matthew
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2015, (09):
  • [7] Stent graft types for endovascular repair of thoracic aortic aneurysms
    Rolph, Rachel
    Duffy, James M. N.
    Waltham, Matthew
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2015, (09):
  • [8] Stent graft types for endovascular repair of abdominal aortic aneurysms
    Duffy, James M. N.
    Rolph, Rachel
    Clough, Rachel E.
    Modarai, Bijan
    Taylor, Peter
    Waltham, Matthew
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2013, (03):
  • [9] Stent graft types for endovascular repair of thoracic aortic aneurysms
    Rolph, Rachel
    Duffy, James M. N.
    Modarai, Bijan
    Clough, Rachel E.
    Taylor, Peter
    Waltham, Matthew
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2013, (03):
  • [10] Performance of the Endurant stent graft in patients with abdominal aortic aneurysms independent of their morphologic suitability for endovascular aneurysm repair based on instructions for use
    Donas, Konstantinos P.
    Torsello, Giovanni
    Weiss, Kristin
    Bisdas, Theodosios
    Eisenack, Markus
    Austermann, Martin
    JOURNAL OF VASCULAR SURGERY, 2015, 62 (04) : 848 - 854