Three-dimensional modeling of the human eye based on magnetic resonance imaging

被引:103
作者
Singh, Krish D.
Logan, Nicola S.
Gilmartin, Bernard
机构
[1] Cardiff Univ, CUBRIC, Cardiff CF10 3AT, S Glam, Wales
[2] Cardiff Univ, Sch Psychol, Cardiff CF10 3AT, S Glam, Wales
[3] Aston Univ, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
关键词
D O I
10.1167/iovs.05-0856
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. A methodology for noninvasively characterizing the three-dimensional (3-D) shape of the complete human eye is not currently available for research into ocular diseases that have a structural substrate, such as myopia. A novel application of a magnetic resonance imaging (MRI) acquisition and analysis technique is presented that, for the first time, allows the 3-D shape of the eye to be investigated fully. METHODS. The technique involves the acquisition of a T-2-weighted MRI, which is optimized to reveal the fluid-filled chambers of the eye. Automatic segmentation and meshing algorithms generate a 3-D surface model, which can be shaded with morphologic parameters such as distance from the posterior corneal pole and deviation from sphericity. Full details of the method are illustrated with data from 14 eyes of seven individuals. The spatial accuracy of the calculated models is demonstrated by-comparing the MRI-derived axial lengths with values measured in the same eyes using interferometry. RESULTS. The color-coded eye models showed substantial variation in the absolute size of the 14 eyes. Variations in the sphericity of the eyes were also evident, with some appearing approximately, spherical whereas others were clearly oblate and one was slightly prolate. Nasal-temporal asymmetries were noted in some subjects. CONCLUSIONS. The MRI acquisition and analysis technique allows a novel way of examining 3-D ocular shape. The ability to stratify and analyze eye shape, ocular volume, and sphericity will further extend the understanding of which specific biometric parameters predispose emmetropic children subsequently to develop myopia.
引用
收藏
页码:2272 / 2279
页数:8
相关论文
共 50 条
[1]   Shape of the retinal surface in emmetropia and myopia [J].
Atchison, DA ;
Pritchard, N ;
Schmid, KL ;
Scott, DH ;
Jones, CE ;
Pope, JM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (08) :2698-2707
[2]   Eye shape in emmetropia and myopia [J].
Atchison, DA ;
Jones, CE ;
Schmid, KL ;
Pritchard, N ;
Pope, JM ;
Strugnell, WE ;
Riley, RA .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (10) :3380-3386
[3]   Dynamic contrast-enhanced MRI measurements of passive permeability through blood retinal barrier in diabetic rats [J].
Berkowitz, BA ;
Roberts, R ;
Luan, HM ;
Peysakhov, J ;
Mao, XZ ;
Thomas, KA .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (07) :2391-2398
[4]   Is eye size related to orbit size in human subjects? [J].
Chau, A ;
Fung, K ;
Pak, K ;
Yap, M .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2004, 24 (01) :35-40
[5]  
CHEN JF, 1992, CLIN VISION SCI, V7, P521
[6]   SHAPE OF THE MYOPIC EYE AS SEEN WITH HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING [J].
CHENG, HM ;
SINGH, OS ;
KWONG, KK ;
XIONG, J ;
WOODS, BT ;
BRADY, TJ .
OPTOMETRY AND VISION SCIENCE, 1992, 69 (09) :698-701
[7]   Retinal stretching limits peripheral visual acuity in myopia [J].
Chui, TYP ;
Yap, MKH ;
Chan, HHL ;
Thibos, LN .
VISION RESEARCH, 2005, 45 (05) :593-605
[8]  
Curtin B.J., 1985, MYOPIAS BASIC SCI CL
[9]  
Dandona R, 2002, INVEST OPHTH VIS SCI, V43, P615
[10]   Magnetic resonance imaging evidence for widespread orbital dysinnervation in congenital fibrosis of extraocular muscles due to mutations in KIF21A [J].
Demer, JL ;
Clark, RA ;
Engle, EC .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (02) :530-539