A comparison of manual and automated methods of measuring conjunctival vessel widths from photographic and digital images

被引:11
作者
Owen, CG
Ellis, TJ
Woodward, EG
机构
[1] St George Hosp, Sch Med, Dept Community Hlth Sci, London SW17 0RE, England
[2] Kingston Univ, Sch Comp & Informat Syst, Kingston upon Thames KT1 2EE, Surrey, England
[3] City Univ London, Dept Optometry & Visual Sci, London EC1V 0HB, England
关键词
automated; conjunctiva; measurement; vessel width;
D O I
10.1046/j.1475-1313.2003.00171.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We investigated the application of a fully automated computer algorithm for identifying vessels of the conjunctiva from their scleral surround, and compared measures of vessel width with established methods. Vessel widths at 101 locations (ranging from 20 to 140 mum), from 12 patients, were measured from film and digital images, using a variety of methods, and compared. Widths were measured manually, by semi-automated methods using grey level (densitometric) profiles taken from digital images, and by automated techniques set at different operating levels. Good intra-session repeatibility was obtained using the automated method with an operating sigma value of 3 pixels (16 mum) (mean difference 0.5 mum, 95% CI -8.5 to 9.4 mum) and manual calliper measurements from digitally created photographic slides (mean difference 0.4 mum, -9.3 to 10.1 mum). For comparison with other measures of width, the latter was used as the gold standard. Widths measured from film were slightly larger than those measured directly from digital images, although this effect was small (5 mum) for most vessels. Overall widths measured using the automated method, with a sigma value of 3 pixels, agreed best with the gold standard (inter-method repeatibility; mean difference 1.4 mum, -32.5 to 35.2 mum) although the automated method overestimated small widths (<40 mum) and underestimated larger vessel widths (>40 mum). Automated detection of vessels of the conjunctiva from digital images avoids manual and operator involved measures which are time consuming, and which preclude large patient studies. The resulting data may help in monitoring the vascular response of the conjunctiva to surgical or pharmacological intervention, and in describing vascular changes in response to ocular or systemic disease. The application of this algorithm to the study of retinal vessels is yet to be realised.
引用
收藏
页码:74 / 81
页数:8
相关论文
共 29 条
[1]   Capillary density and retinal diameter measurements and their impact on altered retinal circulation in glaucoma: a digital fluorescein angiographic study [J].
Arend, O ;
Remky, A ;
Plange, N ;
Martin, BJ ;
Harris, A .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (04) :429-433
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   MEASUREMENT OF VESSEL WIDTH ON FUNDUS PHOTOGRAPHS [J].
BRACHER, D ;
DOZZI, M ;
LOTMAR, W .
ALBRECHT VON GRAEFES ARCHIV FUR KLINISCHE UND EXPERIMENTELLE OPHTHALMOLOGIE, 1979, 211 (01) :35-48
[4]  
Brinchmann-Hansen O, 1986, Acta Ophthalmol Suppl, V179, P1
[5]   Computer algorithms for the automated measurement of retinal arteriolar diameters [J].
Chapman, N ;
Witt, N ;
Gao, X ;
Bharath, AA ;
Stanton, AV ;
Thom, SA ;
Hughes, AD .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (01) :74-79
[6]  
CHEN HC, 1994, INVEST OPHTH VIS SCI, V35, P3199
[7]  
Cheung A T, 2001, Endocr Pract, V7, P358
[8]   Microvascular abnormalities in sickle cell disease: a computer-assisted intravital microscopy study [J].
Cheung, ATW ;
Chen, PCY ;
Larkin, EC ;
Duong, PL ;
Ramanujam, S ;
Tablin, F ;
Wun, T .
BLOOD, 2002, 99 (11) :3999-4005
[9]  
FLOWER RW, 1978, INVEST OPHTH VIS SCI, V17, P562
[10]  
GRUNWALD JE, 1986, ARCH OPHTHALMOL-CHIC, V104, P991