Patients with breast cancer: Differences in color Doppler flow and gray-scale US features of benign and malignant axillary lymph nodes

被引:134
作者
Yang, WT [1 ]
Chang, J
Metreweli, C
机构
[1] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Diagnost Radiol & Organ Imaging, Shatin, Hong Kong, Peoples R China
[2] Natl Univ Singapore, Dept Med Oncol, Singapore 117548, Singapore
关键词
axilla; breast neoplasms; metastases; lymphatic system; neoplasms; US; ultrasound; (US); Doppler studies;
D O I
10.1148/radiology.215.2.r00ap20568
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To document differences in color Doppler flow and gray-scale ultrasonographic (US) features between benign and malignant axillary lymph nodes in women with primary breast cancer. MATERIALS AND METHODS: The longitudinal-transverse axis ratio and hilar status on color Doppler flow and gray-scale US images were prospectively studied for each of 145 axillary nodes in 135 women (74 palpable nodes in 69 women, 71 nonpalpable nodes in 66 women) with primary breast cancer. Intranodal flow distribution was described as peripheral, central, or central perhilar. Resistive and pulsatility indexes and peak systolic velocity were documented. For comparison of benign and malignant features, nodes were divided into three groups: palpable and nonpalpable, palpable, and nonpalpable. RESULTS: Color flow was demonstrated equally well in benign and malignant axillary lymph nodes for all three groups. For all nodes, peripheral flow was significantly higher in malignant (118 of 153 nodes [77%]) than benign (45 of 160 nodes [28%]) nodes (P < .001); central flow and central perhilar flow were significantly greater (P < .002 and < .001, respectively) in benign than malignant nodes. Similar differences were not observed in nonpalpable nodes. The mean longitudinal-transverse axis ratio (+/- SD) was significantly lower in malignant (1.8 +/- 0.6) than benign (2.6 +/- 0.8) nodes. Logistic regression analysis showed peripheral, central, and central perhilar flow and the mean longitudinal-transverse axis ratio to be significant independent predictors of malignancy. CONCLUSION: Color Doppler flow and gray-scale US features applicable to the identification of disease in palpable axillary nodes in patients with breast cancer are not applicable to nonpalpable nodes.
引用
收藏
页码:568 / 573
页数:6
相关论文
共 50 条
  • [1] Benign and malignant breast masses and axillary nodes: Evaluation with echo-enhanced color power Doppler US
    Yang, WT
    Metreweli, C
    Lam, PKW
    Chang, J
    RADIOLOGY, 2001, 220 (03) : 795 - 802
  • [2] Benign and malignant ovarian masses: Selection of the most discriminating gray-scale and Doppler sonographic features
    Brown, DL
    Doubilet, PM
    Miller, FH
    Frates, MC
    Laing, FC
    DiSalvo, DN
    Benson, CB
    Lerner, MH
    RADIOLOGY, 1998, 208 (01) : 103 - 110
  • [3] Gray scale and power Doppler US in the preoperative evaluation of axillary metastases in breast cancer patients with no palpable lymph nodes
    Esen, G
    Gurses, B
    Yilmaz, M
    Ilvan, S
    Ulus, S
    Celik, V
    Farahmand, M
    Calay, OO
    EUROPEAN RADIOLOGY, 2005, 15 (06) : 1215 - 1223
  • [4] Gray scale and power Doppler US in the preoperative evaluation of axillary metastases in breast cancer patients with no palpable lymph nodes
    Gul Esen
    Bengi Gurses
    Mehmet Halit Yilmaz
    Sennur Ilvan
    Sıla Ulus
    Varol Celik
    Mehmet Farahmand
    Ozden Oz Calay
    European Radiology, 2005, 15 : 1215 - 1223
  • [5] PEDIATRIC TESTICULAR-TUMORS - EVALUATION WITH GRAY-SCALE AND COLOR DOPPLER US
    LUKER, GD
    SIEGEL, MJ
    RADIOLOGY, 1994, 191 (02) : 561 - 564
  • [6] Detection of occult metastatic lymph nodes in the neck with gray-scale and power Doppler US
    Wang, Q
    Takashima, S
    Takayama, F
    Wang, JC
    Kawakami, S
    Saito, A
    Matsushita, T
    Sone, S
    ACTA RADIOLOGICA, 2001, 42 (03) : 312 - 319
  • [7] CEREBELLAR AND SPINAL HEMANGIOBLASTOMAS - EVALUATION WITH INTRAOPERATIVE GRAY-SCALE AND COLOR DOPPLER FLOW ULTRASOUND
    AVILA, NA
    SHAWKER, TH
    CHOYKE, PL
    OLDFIELD, EH
    RADIOLOGY, 1993, 188 (01) : 143 - 147
  • [8] LAPAROSCOPIC GRAY-SCALE AND COLOR DOPPLER US - PRELIMINARY ANIMAL AND CLINICAL-STUDIES
    LIU, JB
    FELD, RI
    GOLDBERG, BB
    BARBOT, DJ
    NAZARIAN, LN
    MERTON, DA
    RAWOOL, NM
    ROSATO, FE
    WINKEL, CA
    GILLUM, DR
    VERNICK, JJ
    RADIOLOGY, 1995, 194 (03) : 851 - 857
  • [9] Uterine arteriovenous malformations: Gray-scale and Doppler US features with MR imaging correlation
    Huang, MW
    Muradali, D
    Thurston, WA
    Burns, PN
    Wilson, SR
    RADIOLOGY, 1998, 206 (01) : 115 - 123
  • [10] PROSPECTIVE EVALUATION OF ADNEXAL MASSES WITH ENDOVAGINAL GRAY-SCALE AND DUPLEX AND COLOR DOPPLER US - CORRELATION WITH PATHOLOGICAL FINDINGS
    JAIN, KA
    RADIOLOGY, 1994, 191 (01) : 63 - 67