Utility of Intraoperative Monitoring in the Resection of Spinal Cord Tumors

被引:33
|
作者
Lakomkin, Nikita [1 ]
Mistry, Akshitkumar M. [2 ]
Zuckerman, Scott L. [2 ]
Ladner, Travis [1 ]
Kothari, Parth [1 ]
Lee, Nathan J. [1 ]
Stannard, Blaine [2 ]
Vasquez, Raul A. [3 ]
Cheng, Joseph S. [4 ]
机构
[1] Icahn Sch Med Mt Sinai, Dept Neurosurg, 1 Gustave Levy Pl, New York, NY 10029 USA
[2] Vanderbilt Univ, Med Ctr, Dept Neurol Surg, Nashville, TN USA
[3] Univ Kentucky, Dept Neurosurg, Lexington, KY USA
[4] Univ Cincinnati, Dept Neurosurg, Cincinnati, OH USA
关键词
intramedullary; intraoperative neuromonitoring; motor-evoked potentials; somatosensory evoked potentials; transcranial motor evoked potentials; MOTOR EVOKED-POTENTIALS; NEUROPHYSIOLOGICAL DATA; CONSECUTIVE PROCEDURES; SURGERY CORRELATION;
D O I
10.1097/BRS.0000000000002300
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Retrospective review of institutional data. Objective. The aim of this study was to assess the utility of somatosensory-evoked potentials (SSEP) and transcranial electric motor-evoked potentials (MEP) in the resection of spine tumors and evaluate the ability of both single and multi-modal monitoring to predict postoperative neurological deficits. Summary of Background Data. Although the utility of intraoperative monitoring (IOM) is well established in scoliosis and degenerative surgery, studies in spine tumor patients have been limited. Methods. A series of consecutive patients who underwent resection with the use of 10M at a single institution between August 2009 and March 2013 was identified. Demographic, clinical, and neuromonitoring data were collected preoperatively, during surgery, at the moment of discharge, and at a 6-month follow-up visit. Three cohorts were established based on the anatomical location of the tumor: intramedullary, intradural extramedullary, and extradural. Additional groupings were formed based on spinal region. Patients with significant changes in SSEPs or MEPs during surgery were identified and the rate of neurological deficits was assessed. Results. A total of 52 patients were analyzed. A change in SSEPs or MEPs was detected in 11 (21.2%) cases whereas 14 patients (26.9%) developed permanent postoperative deficits.SSEPs predicted deficits in the resection of intramedullary tumors (P=0.015) (area under cover, AUC= 0.83), and intradural extramedullary tumors (P=0.048; AUC = 0.70). MEP monitoring did not predict postoperative deficits in the resection of intramedullary (P=0.21; AUC = 0.69) or intradural extramedullary tumors (P=0.31; AUC= 0.63). Neither SSEPs nor MEPs predicted deficits for extradural tumors. Conclusion. The efficacy of 10M in spine tumor resection is dependent on tumor location relative to the spinal cord and dura. The accuracy of SSEPs and their ability to predict postoperative deficits was greatest for intramedullary lesions. For this series, MEP and multi-modal monitoring did not confer a benefit in predicting permanent neurological deficits.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 50 条
  • [41] Neurophysiological monitoring in spinal cord surgery
    Angel Collado-Corona, Miguel
    de Leo-Vargas, Roberto
    Sandoval-Sanchez, Victor
    Diaz-Hernandez, Alejandro
    Jose Gutierrez-Sougarret, Bernardo
    Shkurovich-Bialik, Paul
    CIRUGIA Y CIRUJANOS, 2009, 77 (05): : 361 - 366
  • [42] Intraoperative Neurophysiologic Spinal Cord Monitoring in Thoracolumbar Burst Fractures
    Castellon, Alfredo T.
    Meves, Robert
    Avanzi, Osmar
    SPINE, 2009, 34 (24) : 2662 - 2668
  • [43] Spinal deformity after resection of cervical intramedullary spinal cord tumors in children
    McGirt, Matthew J.
    Chaichana, Kaisorn L.
    Attenello, Frank
    Witham, Timothy
    Bydon, Ali
    Yao, Kevin C.
    Jallo, George I.
    CHILDS NERVOUS SYSTEM, 2008, 24 (06) : 735 - 739
  • [44] Spinal deformity after resection of cervical intramedullary spinal cord tumors in children
    Matthew J. McGirt
    Kaisorn L. Chaichana
    Frank Attenello
    Timothy Witham
    Ali Bydon
    Kevin C. Yao
    George I. Jallo
    Child's Nervous System, 2008, 24 : 735 - 739
  • [45] Utility of neurophysiological monitoring using dorsal column mapping in intramedullary spinal cord surgery Clinical article
    Yanni, Daniel S.
    Ulkatan, Sedat
    Deletis, Vedran
    Barrenechea, Ignacio J.
    Sen, Chandranath
    Perin, Noel I.
    JOURNAL OF NEUROSURGERY-SPINE, 2010, 12 (06) : 623 - 628
  • [46] Intraoperative neurophysiological monitoring during complex spinal deformity cases in pediatric patients: methodology, utility, prognostication, and outcome
    Drake, James
    Zeller, Reinhard
    Kulkarni, Abhaya V.
    Strantzas, Samuel
    Holmes, Laura
    CHILDS NERVOUS SYSTEM, 2010, 26 (04) : 523 - 544
  • [47] Surgical Management of Intramedullary Spinal Cord Tumors
    Hussain, Ibrahim
    Parker, Whitney E.
    Barzilai, Ori
    Bilsky, Mark H.
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2020, 31 (02) : 237 - +
  • [48] Assessment of intraoperative neurophysiological monitoring techniques in intramedullary spinal cord tumor removal surgery
    Nguyen, Minh Anh
    Ngo, Anh Phung
    Huynh, Quoc Bao
    Pham, Thanh Binh
    Nguyen, Viet Hoa
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2023, 32
  • [49] Diagnostic and therapeutic values of intraoperative electrophysiological neuromonitoring during resection of intradural extramedullary spinal tumors: a single-center retrospective cohort and meta-analysis
    Ishida, Wataru
    Casaos, Joshua
    Chandra, Arun
    D'Sa, Adam
    Ramhmdani, Seba
    Perdomo-Pantoja, Alexander
    Theodore, Nicholas
    Jallo, George
    Gokaslan, Ziya L.
    Wolinsky, Jean-Paul
    Sciubba, Daniel M.
    Bydon, Ali
    Witham, Timothy F.
    Lo, Sheng-Fu L.
    JOURNAL OF NEUROSURGERY-SPINE, 2019, 30 (06) : 839 - 849
  • [50] Intraoperative neurophysiological monitoring for intradural extramedullary tumors: Why not?
    Ghadirpour, Reza
    Nasi, Davide
    Iaccarino, Corrado
    Giraldi, David
    Sabadini, Rossella
    Motti, Luisa
    Sala, Francesco
    Servadei, Franco
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2015, 130 : 140 - 149