Analysis of the effect of tibial torsion on tibial osteotomy in knee arthroplasty using a three-dimensional computed tomography-based modelling technique

被引:3
作者
Li, Yeran [1 ]
Gao, Yu-Hang [1 ]
Lu-Ding [1 ]
Liu, Jianguo [1 ]
Yang, Chen [1 ]
Li, Ming [1 ]
Qi, Xin [1 ]
机构
[1] Jilin Univ, Dept Orthopaed Surg, Hosp 1, Xinmin St 71, Changchun 130021, Jilin, Peoples R China
关键词
Tibial torsion; Alignment deviation; Knee arthroplasty; Extramedullary system; 3D model; PROXIMAL TIBIA; ALIGNMENT; COMPONENT; ROTATION; VARIABILITY;
D O I
10.1186/s12891-019-2744-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Extramedullary systems are commonly used in knee arthroplasty, with the rod location being determined from the tibial torsion line during surgery. The traditional method for tibial torsion measurement is not in accordance with clinical practice. This study aimed to evaluate proximal and distal tibial torsion using 3-dimensional (3D) computed technology to establish a new evaluation method, as well as to investigate the association between tibial torsion and postoperative alignment deviation. Methods Fifty-five osteoarthritis tibias with >10 degrees varus preoperatively were divided into valgus, neutral, and varus groups based on their postoperative alignment deviation. A new method based on clinical practice was built using a 3D tibial model. Proximal and distal tibial torsions were measured by both the new and traditional methods. In addition, tibial osteotomy that followed the intramedullary osteotomy system was simulated on the 3D model in the varus and valgus groups to investigate the association between tibial torsion and alignment deviation. Results Proximal tibial torsion was smaller and distal torsion was greater in the valgus group than the other two groups, according to the new method (p = 0.03 and p = 0.02, respectively). No significant difference was found when comparing these torsions by the traditional method (p = 0.782 and p = 0.753, respectively). In the valgus group, the postoperative alignment deviation improved after simulated osteotomy guided by the intramedullary system, while no significant improvement was found in the varus group. Conclusion According to this new tibial-rotation evaluation method, valgus deviation in knee arthroplasty was identified as the main cause for knees in which the proximal tibial internal torsion is too small and the distal external torsion is too great. The use of an intramedullary system may help reduce this deviation.
引用
收藏
页数:8
相关论文
共 17 条
  • [1] Variability of extraarticular tibial rotation references for total knee arthroplasty
    Akagi, M
    Mori, S
    Nishimura, S
    Nishimura, A
    Asano, T
    Hamanishi, C
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) : 172 - 176
  • [2] Effects of tibial torsion on distal alignment of extramedullary instrumentation in total knee arthroplasty
    Cinotti, Gianluca
    Sessa, Pasquale
    Della Rocca, Antonello
    Ripani, Francesca Romana
    Giannicola, Giuseppe
    [J]. ACTA ORTHOPAEDICA, 2013, 84 (03) : 275 - 279
  • [3] Cotia D., 2009, JURNALUL PEDIATRULUI, p[3, 45]
  • [4] Dalury DF, 2001, CLIN ORTHOP RELAT R, P150
  • [5] ECKHOFF DG, 1994, CLIN ORTHOP RELAT R, P42
  • [6] Gandhi Swati, 2014, Biomed J, V37, P10, DOI 10.4103/2319-4170.117890
  • [7] 3D patient-specific model of the tibia from CT for orthopedic use
    Gonzalez-Carbonell, Raide A.
    Ortiz-Prado, Armando
    Jacobo-Armendariz, Victor H.
    Cisneros-Hidalgo, Yosbel A.
    Alpizar-Aguirre, Armando
    [J]. JOURNAL OF ORTHOPAEDICS, 2015, 12 (01) : 11 - 16
  • [8] Variability of the location of the tibial tubercle affects the rotational alignment of the tibial component in kinematically aligned total knee arthroplasty
    Howell, Stephen M.
    Chen, Justin
    Hull, Maury L.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) : 2288 - 2295
  • [9] Rotational Profile of Lower Limb and Axis for Tibial Component Alignment in Varus Osteoarthritic Knees
    Khan, Mohammad Shahnawaz
    Seon, Jong Keun
    Song, Eun Kyoo
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (05) : 797 - 802
  • [10] Miller MC, 2001, CLIN ORTHOP RELAT R, P38