摘要
It is possible to produce a high-performance, flexible 1-3 connectivity piezoelectric ceramic composite with conventional methods but the process is difficult and time-consuming. Extensive finite element modeling was used to design a piezocomposite structure which incorporated randomly positioned piezoceramic fibers in a polymer matrix. Simple manufacturing techniques were developed which resulted in the production of large numbers of fully populated fiber composites that offered performance comparable with a conventional 1-3 piezocomposite. A modified process facilitated the production of efficient fiber piezocomposite elements separated by polymer channels which conformed to a highly flexible (13 mm radius of curvature), 2-D matrix array configuration. This arrangement has been termed a Composite Element Composite Array Transducer, or CECAT. These devices were evaluated in terms of their impedance spectra, pulse-echo response, and surface displacement characteristics. The random piezoceramic fiber arrangements showed comparable sensitivity and bandwidth to periodic devices while minimizing the parasitic interpillar modes associated with periodic structures. Investigations have indicated that CECAT arrays constructed with 250 mu m diameter fibers can be operated at frequencies of up to 3 MHz and transducers incorporating 105 mu m diameter fibers can extend the frequency range above 6 MHz. Conversely, improved low-frequency devices can be produced with taller pillars than possible with conventional manufacturing techniques.
引用
收藏
页码:1999 / 2009
页数:11
相关论文
共 50 条
  • [1] Integrated and Flexible Piezoelectric Ultrasonic Transducers
    Jen, C. -K.
    Kobayashi, M.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 1119 - 1127
  • [2] Flexible piezoelectric micromachined ultrasonic transducers towards new applications
    Sun, Sheng
    Zhang, Menglun
    Gao, Chuanhai
    Liu, Bohua
    Pang, Wei
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [3] Flexible ultrasonic transducers
    Kobayashi, Makiko
    Jen, Cheng-Kuei
    Levesque, Daniel
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (08) : 1478 - 1486
  • [4] OPTIMIZATION OF ULTRASONIC PIEZOELECTRIC TRANSDUCERS
    BOGOMOLHYI, VM
    CHEMICAL AND PETROLEUM ENGINEERING, 1994, 30 (5-6) : 199 - 201
  • [5] PIEZOELECTRIC CERAMICS AND ULTRASONIC TRANSDUCERS
    GALLEGOJUAREZ, JA
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1989, 22 (10): : 804 - 816
  • [6] Structural Health Monitoring of Composites Using Integrated and Flexible Piezoelectric Ultrasonic Transducers
    Kobayashi, Makiko
    Wu, Kuo-Ting
    Song, Li
    Jen, Cheng-Kuei
    Mrad, Nezih
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2009, 20 (08) : 969 - 977
  • [7] Flexible Ultrasonic Transducers Using Piezoelectric Fiber Composites with Antisymmetric Interdigital Electrodes
    Yin, Ching-Chung
    Wu, Yu-Chien
    Liu, Yu-Shyan
    Hsu, Shih-Ming
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 675 - 678
  • [8] ULTRASONIC TRANSDUCERS WITH PIEZOELECTRIC POLYMER FOIL
    HARNISCH, F
    KROEMER, N
    MANTHEY, W
    SENSORS AND ACTUATORS A-PHYSICAL, 1991, 26 (1-3) : 549 - 552
  • [9] PIEZOELECTRIC TRANSDUCERS AS ULTRASONIC POWER STANDARDS
    ZAPF, TL
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1975, SU22 (03): : 225 - 225
  • [10] INSPECTION OF THE QUALITY OF ULTRASONIC PIEZOELECTRIC TRANSDUCERS
    GITIS, MB
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1984, 20 (01): : 65 - 70