Technical accuracy of a neuronavigation system measured with a high-precision mechanical micromanipulator

被引:58
|
作者
Kaus, M
Steinmeier, R
Sporer, T
Ganslandt, O
Fahlbusch, R
机构
[1] UNIV ERLANGEN NURNBERG, NEUROCHIRURG KLIN, D-91054 ERLANGEN, GERMANY
[2] UNIV ERLANGEN NURNBERG, LEHRSTUHL TECH ELEKT, D-91054 ERLANGEN, GERMANY
关键词
accuracy; micromanipulator; neuronavigation;
D O I
10.1097/00006123-199712000-00046
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: This study was designed to determine and evaluate the different system-inherent sources of erroneous target localization of a light-emitting diode (LED)-based neuronavigation system (StealthStatisn, Stealth Technologies, Boulder, CO). METHODS: The localization accuracy was estimated by applying a high-precision mechanical micromanipulator to move and exactly locate (+/-0.1 mu m) the pointer at multiple positions in the physical three-dimensional space. The localization error was evaluated by calculating the spatial distance between the (known) LED positions and the LED coordinates measured by the neuronavigator, The results are based on a study of approximately 280,000 independent coordinate measurements. RESULTS: The maximum localization error detected was 0.55 +/- 0.29 mm, with the z direction (distance to the camera array) being the most erroneous coordinate. Minimum localization error was found at a distance of 1400 mm from the central camera (optimal measurement position). Additional error due to 1) mechanical vibrations of the camera tripod (+/-0.15 mm) and the reference frame (+/-0.08 mm) and 2) extrapolation of the pointer tip position from the LED coordinates of at least +/-0.12 mm were detected, leading to a total technical error of 0.55 +/- 0.64 mm. CONCLUSIONS: Based on this technical accuracy analysis, a set of handling recommendations is proposed, leading to an improved localization accuracy. The localization error could be reduced by 0.3 +/- 0.15 mm by correct camera positioning (1400 mm distance) plus 0.15 mm by vibration-eliminating fixation of the camera. Correct handling of the probe during the operation may improve the accuracy by up to 0.1 mm.
引用
收藏
页码:1431 / 1436
页数:6
相关论文
共 24 条
  • [21] A Fast and High-Precision Correction Method of Time Uniform System Deviation Based on Double Quadratic Polynomial Fittings
    Cao, Rui
    Yang, Yaodong
    Gu, Xianglong
    Qi, Xiaoyu
    Hu, Yaxiong
    PROCEEDINGS OF 2020 IEEE 5TH INFORMATION TECHNOLOGY AND MECHATRONICS ENGINEERING CONFERENCE (ITOEC 2020), 2020, : 1708 - 1712
  • [22] The Wearable VOSTARS System for Augmented Reality-Guided Surgery: Preclinical Phantom Evaluation for High-Precision Maxillofacial Tasks
    Cercenelli, Laura
    Carbone, Marina
    Condino, Sara
    Cutolo, Fabrizio
    Marcelli, Emanuela
    Tarsitano, Achille
    Marchetti, Claudio
    Ferrari, Vincenzo
    Badiali, Giovanni
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (11) : 1 - 13
  • [23] High-Precision Time-Frequency Signal Simultaneous Transfer System via a WDM-Based Fiber Link
    Zang, Qi
    Quan, Honglei
    Zhao, Kan
    Zhang, Xiang
    Deng, Xue
    Xue, Wenxiang
    Chen, Faxi
    Liu, Tao
    Dong, Ruifang
    Zhang, Shougang
    PHOTONICS, 2021, 8 (08)
  • [24] Semi-natural simulation of the angular matching of the axes of the working and marker laser beams in a high-precision laser ranging system
    Kolenchikov, K. K.
    Malinov, V. A.
    Pavlov, N., I
    Popikov, V. S.
    Potapova, N., I
    Charukhchev, A., V
    JOURNAL OF OPTICAL TECHNOLOGY, 2022, 89 (07) : 400 - 408