Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry

被引:34
作者
Hsu, S-Y [1 ,2 ,3 ]
Sheu, M-M [1 ,3 ]
Hsu, A-H [6 ]
Wu, K-Y [4 ,5 ]
Yeh, J-I [7 ]
Tien, J-N [8 ]
Tsai, R-K [1 ,3 ]
机构
[1] Tzu Chi Univ, Dept Ophthalmol, Buddhist Tzu Chi Gen Hosp, Hualien 970, Taiwan
[2] Tzu Chi Univ, Inst Med Sci, Hualien 970, Taiwan
[3] Tzu Chi Univ, Dept Ophthalmol & Visual Sci, Inst Med, Coll Med, Hualien 970, Taiwan
[4] Kaohsiung Med Univ, Dept Ophthalmol, Chung Ho Mem Hosp, Kaohsiung, Taiwan
[5] Kaohsiung Med Univ, Fac Med, Coll Med, Kaohsiung, Taiwan
[6] Buddhist Tzu Chi Gen Hosp, Dept Internal Med, Hualien, Taiwan
[7] Buddhist Tzu Chi Gen Hosp, Dept Family Med, Hualien, Taiwan
[8] Tzu Chi Univ, Branch Publ Hlth, Inst Med Sci, Coll Med, Hualien 970, Taiwan
关键词
corneal curvature; corneal thickness; lens thickness; ocular pulse amplitude; tonometry; CENTRAL CORNEAL THICKNESS; OCULAR RESPONSE ANALYZER; BIOMECHANICAL PROPERTIES; PULSE AMPLITUDE; AGE; CURVATURE; GLAUCOMA; PATIENT; EYES;
D O I
10.1038/eye.2009.77
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To compare intraocular pressure (IOP) readings between Tono-Pen tonometry and GAT, between noncontact tonometry (NCT) and GAT, and between dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT). The correlation between IOP reading and possible confounder was identified. Methods This observational cross-sectional study enrolled sixty-two healthy subjects. All IOP and ocular pulse amplitude (OPA) measurements were taken by a single ophthalmologist; mean keratometric power (MK), central corneal thickness (CCT), and lens thickness (LT) were measured by a single experienced technician. Results Stepwise multiple regression analysis indicated that GAT (P=0.017) and DCT (P=0.002) readings correlated positively with MK; GAT, NCT, and Tono-Pen readings correlated positively with CCT (P<0.05); NCT (P=0.035), and DCT (P=0.016) readings correlated negatively with LT; GAT (P=0.006) and Tono-Pen (P=0.009) readings correlated positively with OPA. Conclusions The K, CCT, LT, and OPA are confounders in tonometry readings. Eye (2009) 23, 1582-1588; doi:10.1038/eye.2009.77; published online 1 May 2009
引用
收藏
页码:1582 / 1588
页数:7
相关论文
共 50 条
  • [41] Comparison of the Utility of Pascal Dynamic Contour Tonometry With Goldmann Applanation Tonometry in Routine Clinical Practice
    Anderson, Matthew Frederick
    Agius-Fernandez, Adriana
    Kaye, Stephen B.
    JOURNAL OF GLAUCOMA, 2013, 22 (05) : 422 - 426
  • [42] Repeatability and Reproducibility for Intraocular Pressure Measurement by Dynamic Contour, Ocular Response Analyzer, and Goldmann Applanation Tonometry
    Sullivan-Mee, Michael
    Gerhardt, Gretchen
    Halverson, Kathy D.
    Qualls, Clifford
    JOURNAL OF GLAUCOMA, 2009, 18 (09) : 666 - 673
  • [44] Intraocular pressure elevation after vitrectomy-Goldmann applanation tonometry measures lower intraocular pressure than dynamic contour tonometry
    Baeurle, Sebastian
    Viestenz, Anja
    Seitz, Berthold
    Viestenz, Arne
    OPHTHALMOLOGE, 2022, 119 (SUPPL 1): : 71 - 76
  • [45] Correlation between Central Corneal Thickness and Intraocular Pressure Measured by Goldmann Applanation Tonometry or Pascal Dynamic Contour Tonometry
    Katsimpris, J. M.
    Theoulakis, P. E.
    Vasilopoulos, K.
    Skourtis, G.
    Papadopoulos, G. E.
    Petropoulos, I. K.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (04) : 414 - 418
  • [46] Dynamic contour tonometry (DCT) versus Goldmann applanation tonometry (GAT) - a comparison of agreement and reproducibility
    Sonja Herdener
    Mona Pache
    Sonja Lautebach
    Jens Funk
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2006, 245 : 1027 - 1030
  • [47] Dynamic contour tonometry (DCT) versus Goldmann applanation tonometry (GAT) - a comparison of agreement and reproducibility
    Herdener, Sonja
    Pache, Mona
    Lautebach, Sonja
    Funk, Jens
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (07) : 1027 - 1030
  • [48] Goldmann Applanation Tonometry versus Dynamic Contour Tonometry after Vitrectomy with Silicone Oil Endotamponade
    Fuest, Matthias
    Mamas, Nikolaos
    Walter, Peter
    Mazinani, Babac E.
    Roessler, Gemot
    Plange, Niklas
    CURRENT EYE RESEARCH, 2017, 42 (07) : 1007 - 1012
  • [49] Intraocular Pressure Values Obtained by Ocular Response Analyzer, Dynamic Contour Tonometry, and Goldmann Tonometry in Keratokonic Corneas
    Bayer, Atilla
    Sahin, Afsun
    Hurmeric, Volkan
    Ozge, Gokhan
    JOURNAL OF GLAUCOMA, 2010, 19 (08) : 540 - 545
  • [50] Comparison of rebound tonometry and non-contact airpuff tonometry to Goldmann applanation tonometry
    Demirci, Goktug
    Erdur, Sevil Karaman
    Tanriverdi, Cafer
    Gulkitik, Gokhan
    Ozsutcu, Mustafa
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2019, 11