Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry

被引:34
作者
Hsu, S-Y [1 ,2 ,3 ]
Sheu, M-M [1 ,3 ]
Hsu, A-H [6 ]
Wu, K-Y [4 ,5 ]
Yeh, J-I [7 ]
Tien, J-N [8 ]
Tsai, R-K [1 ,3 ]
机构
[1] Tzu Chi Univ, Dept Ophthalmol, Buddhist Tzu Chi Gen Hosp, Hualien 970, Taiwan
[2] Tzu Chi Univ, Inst Med Sci, Hualien 970, Taiwan
[3] Tzu Chi Univ, Dept Ophthalmol & Visual Sci, Inst Med, Coll Med, Hualien 970, Taiwan
[4] Kaohsiung Med Univ, Dept Ophthalmol, Chung Ho Mem Hosp, Kaohsiung, Taiwan
[5] Kaohsiung Med Univ, Fac Med, Coll Med, Kaohsiung, Taiwan
[6] Buddhist Tzu Chi Gen Hosp, Dept Internal Med, Hualien, Taiwan
[7] Buddhist Tzu Chi Gen Hosp, Dept Family Med, Hualien, Taiwan
[8] Tzu Chi Univ, Branch Publ Hlth, Inst Med Sci, Coll Med, Hualien 970, Taiwan
关键词
corneal curvature; corneal thickness; lens thickness; ocular pulse amplitude; tonometry; CENTRAL CORNEAL THICKNESS; OCULAR RESPONSE ANALYZER; BIOMECHANICAL PROPERTIES; PULSE AMPLITUDE; AGE; CURVATURE; GLAUCOMA; PATIENT; EYES;
D O I
10.1038/eye.2009.77
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To compare intraocular pressure (IOP) readings between Tono-Pen tonometry and GAT, between noncontact tonometry (NCT) and GAT, and between dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT). The correlation between IOP reading and possible confounder was identified. Methods This observational cross-sectional study enrolled sixty-two healthy subjects. All IOP and ocular pulse amplitude (OPA) measurements were taken by a single ophthalmologist; mean keratometric power (MK), central corneal thickness (CCT), and lens thickness (LT) were measured by a single experienced technician. Results Stepwise multiple regression analysis indicated that GAT (P=0.017) and DCT (P=0.002) readings correlated positively with MK; GAT, NCT, and Tono-Pen readings correlated positively with CCT (P<0.05); NCT (P=0.035), and DCT (P=0.016) readings correlated negatively with LT; GAT (P=0.006) and Tono-Pen (P=0.009) readings correlated positively with OPA. Conclusions The K, CCT, LT, and OPA are confounders in tonometry readings. Eye (2009) 23, 1582-1588; doi:10.1038/eye.2009.77; published online 1 May 2009
引用
收藏
页码:1582 / 1588
页数:7
相关论文
共 50 条
  • [31] The Impact of Corneal Edema on Intraocular Pressure Measurements Using Goldmann Applanation Tonometry, Tono-Pen XL, iCare, and ORA: An In Vitro Model
    Neuburger, Matthias
    Maier, Philip
    Boehringer, Daniel
    Reinhard, Thomas
    Jordan, Jens F.
    JOURNAL OF GLAUCOMA, 2013, 22 (07) : 584 - 590
  • [32] International comparisons of intraocular pressures, as measured by Tono-Pen and Goldmann applanation tonometry, in healthy adults: A meta-analysis
    Keller, William J.
    MEDICINE, 2023, 102 (10) : e33078
  • [33] Comparison of Intraocular Pressure Measurements With Goldmann Applanation Tonometry, Tonopen XL, and Pascal Dynamic Contour Tonometry in Patients With Descemet Membrane Endothelial Keratoplasty
    Yildiz, Izlem
    Altan, Cigdem
    Cakmak, Semih
    Genc, Selim
    Yildirim, Yusuf
    Agca, Alper
    JOURNAL OF GLAUCOMA, 2022, 31 (11) : 909 - 914
  • [34] Dynamic contour tonometry versus Goldmann applanation tonometry: challenging the gold standard
    Bochmann, Frank
    Kaufmann, Claude
    Thiel, Michael A.
    EXPERT REVIEW OF OPHTHALMOLOGY, 2010, 5 (06) : 743 - 749
  • [35] Corneal Modulus and IOP Measurements in Canine Eyes Using Goldmann Applanation Tonometry and Tono-pen
    Tang, Junhua
    Pan, Xueliang
    Weber, Paul A.
    Liu, Jun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (11) : 7866 - 7871
  • [36] Goldmann Applanation Tonometry and Dynamic Contour Tonometry After Treatment With Prostaglandin Analog/Prostamide
    Ang, Ghee Soon
    Wells, Anthony P.
    JOURNAL OF GLAUCOMA, 2010, 19 (05) : 346 - 346
  • [37] Goldmann applanation tonometry and dynamic contour tonometry in eyes with elevated intraocular pressure (IOP): comparison in the same eyes after subsequent medical normalization of IOP
    Yoo, Chungkwon
    Eom, Young Sub
    Kim, Yong Yeon
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (11) : 1611 - 1616
  • [38] IOP Measured by Dynamic Contour Tonometry Correlates With IOP Measured by Goldmann Applanation Tonometry and Non-contact Tonometry in Japanese Individuals
    Ito, Ken
    Tawara, Akihiko
    Kubota, Toshiaki
    Harada, Yukinori
    JOURNAL OF GLAUCOMA, 2012, 21 (01) : 35 - 40
  • [39] A comparison of intraocular pressure measurements with the XPERT noncontact tonometer and Goldmann applanation tonometry
    Popovich, KS
    Shields, MB
    JOURNAL OF GLAUCOMA, 1997, 6 (01) : 44 - 46
  • [40] Differences between Goldmann Applanation Tonometry and Dynamic Contour Tonometry in pseudoexfoliation syndrome
    Grammenandi, Emilia
    Detorakis, Efstathios T.
    Pallikaris, Ioannis G.
    Tsilimbaris, Miltiadis K.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 38 (05) : 444 - 448