Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry

被引:34
作者
Hsu, S-Y [1 ,2 ,3 ]
Sheu, M-M [1 ,3 ]
Hsu, A-H [6 ]
Wu, K-Y [4 ,5 ]
Yeh, J-I [7 ]
Tien, J-N [8 ]
Tsai, R-K [1 ,3 ]
机构
[1] Tzu Chi Univ, Dept Ophthalmol, Buddhist Tzu Chi Gen Hosp, Hualien 970, Taiwan
[2] Tzu Chi Univ, Inst Med Sci, Hualien 970, Taiwan
[3] Tzu Chi Univ, Dept Ophthalmol & Visual Sci, Inst Med, Coll Med, Hualien 970, Taiwan
[4] Kaohsiung Med Univ, Dept Ophthalmol, Chung Ho Mem Hosp, Kaohsiung, Taiwan
[5] Kaohsiung Med Univ, Fac Med, Coll Med, Kaohsiung, Taiwan
[6] Buddhist Tzu Chi Gen Hosp, Dept Internal Med, Hualien, Taiwan
[7] Buddhist Tzu Chi Gen Hosp, Dept Family Med, Hualien, Taiwan
[8] Tzu Chi Univ, Branch Publ Hlth, Inst Med Sci, Coll Med, Hualien 970, Taiwan
关键词
corneal curvature; corneal thickness; lens thickness; ocular pulse amplitude; tonometry; CENTRAL CORNEAL THICKNESS; OCULAR RESPONSE ANALYZER; BIOMECHANICAL PROPERTIES; PULSE AMPLITUDE; AGE; CURVATURE; GLAUCOMA; PATIENT; EYES;
D O I
10.1038/eye.2009.77
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To compare intraocular pressure (IOP) readings between Tono-Pen tonometry and GAT, between noncontact tonometry (NCT) and GAT, and between dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT). The correlation between IOP reading and possible confounder was identified. Methods This observational cross-sectional study enrolled sixty-two healthy subjects. All IOP and ocular pulse amplitude (OPA) measurements were taken by a single ophthalmologist; mean keratometric power (MK), central corneal thickness (CCT), and lens thickness (LT) were measured by a single experienced technician. Results Stepwise multiple regression analysis indicated that GAT (P=0.017) and DCT (P=0.002) readings correlated positively with MK; GAT, NCT, and Tono-Pen readings correlated positively with CCT (P<0.05); NCT (P=0.035), and DCT (P=0.016) readings correlated negatively with LT; GAT (P=0.006) and Tono-Pen (P=0.009) readings correlated positively with OPA. Conclusions The K, CCT, LT, and OPA are confounders in tonometry readings. Eye (2009) 23, 1582-1588; doi:10.1038/eye.2009.77; published online 1 May 2009
引用
收藏
页码:1582 / 1588
页数:7
相关论文
共 50 条
  • [21] Comparison between dynamic contour tonometry and Goldmann applanation tonometry correcting equations
    De Bernardo, Maddalena
    Casaburi, Claudia
    De Pascale, Ilaria
    Capasso, Luigi
    Cione, Ferdinando
    Rosa, Nicola
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [22] Dynamic contour tonometry versus Goldmann applanation tonometry: a comparative study
    Mona Pache
    Sonja Wilmsmeyer
    Sonja Lautebach
    Jens Funk
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2005, 243 : 763 - 767
  • [23] Goldmann Applanation Tonometry Versus Dynamic Contour Tonometry After Vitrectomy
    Mamas, Nikolaos
    Fuest, Matthias
    Koutsonas, Antonios
    Roessler, Gernot
    Mazinani, Babac E.
    Walter, Peter
    Plange, Niklas
    JOURNAL OF GLAUCOMA, 2016, 25 (08) : 663 - 668
  • [24] Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes
    P Ceruti
    R Morbio
    M Marraffa
    G Marchini
    Eye, 2009, 23 : 262 - 269
  • [25] Differences between Goldmann Applanation Tonometry and Dynamic Contour Tonometry following Trabeculectomy
    Detorakis, Efstathios T.
    Grammenandi, Emilia
    Pallikaris, Ioannis G.
    Tsilimbaris, Miltiadis K.
    JOURNAL OF OPHTHALMOLOGY, 2010, 2010
  • [26] Assessment of intraocular pressure measured by Reichert Ocular Response Analyzer, Goldmann Applanation Tonometry, and Dynamic Contour Tonometry in healthy individuals
    Ouyang, Ping-Bo
    Li, Cong-Yi
    Zhu, Xiao-Hua
    Duan, Xuan-Chu
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2012, 5 (01) : 102 - 107
  • [27] Comparisons between Pascal dynamic contour tonometry, the TonoPen, and Goldmann applanation tonometry in patients with glaucoma
    Salvetat, Maria L.
    Zeppieri, Marco
    Tosoni, Claudia
    Brusini, Paolo
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (03): : 272 - 279
  • [28] Measurement of intraocular pressure using the Tono-Pen in comparison with Goldmann applanation tonometry - a clinical study in 100 eyes
    Deuter, CME
    Schlote, T
    Hahn, GA
    Bende, T
    Derse, M
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2002, 219 (03) : 138 - 142
  • [29] Comparison of dynamic contour tonometry and Goldmann applanation tonometry following penetrating keratoplasty
    Kandarakis, Artemios
    Soumplis, Vasileios
    Pitsas, Christos
    Kandarakis, Stylianos
    Halikias, Jiannis
    Karagiannis, Dimitrios
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2010, 45 (05): : 489 - 493
  • [30] Correlation Between Dynamic Contour Tonometry, Uncorrected and Corrected Goldmann Applanation Tonometry, and Stage of Glaucoma
    Wachtl, Josephine
    Toteberg-Harms, Marc
    Frimmel, Sonja
    Roos, Malgorzata
    Kniestedt, Christoph
    JAMA OPHTHALMOLOGY, 2017, 135 (06) : 601 - 608