Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry

被引:34
作者
Hsu, S-Y [1 ,2 ,3 ]
Sheu, M-M [1 ,3 ]
Hsu, A-H [6 ]
Wu, K-Y [4 ,5 ]
Yeh, J-I [7 ]
Tien, J-N [8 ]
Tsai, R-K [1 ,3 ]
机构
[1] Tzu Chi Univ, Dept Ophthalmol, Buddhist Tzu Chi Gen Hosp, Hualien 970, Taiwan
[2] Tzu Chi Univ, Inst Med Sci, Hualien 970, Taiwan
[3] Tzu Chi Univ, Dept Ophthalmol & Visual Sci, Inst Med, Coll Med, Hualien 970, Taiwan
[4] Kaohsiung Med Univ, Dept Ophthalmol, Chung Ho Mem Hosp, Kaohsiung, Taiwan
[5] Kaohsiung Med Univ, Fac Med, Coll Med, Kaohsiung, Taiwan
[6] Buddhist Tzu Chi Gen Hosp, Dept Internal Med, Hualien, Taiwan
[7] Buddhist Tzu Chi Gen Hosp, Dept Family Med, Hualien, Taiwan
[8] Tzu Chi Univ, Branch Publ Hlth, Inst Med Sci, Coll Med, Hualien 970, Taiwan
关键词
corneal curvature; corneal thickness; lens thickness; ocular pulse amplitude; tonometry; CENTRAL CORNEAL THICKNESS; OCULAR RESPONSE ANALYZER; BIOMECHANICAL PROPERTIES; PULSE AMPLITUDE; AGE; CURVATURE; GLAUCOMA; PATIENT; EYES;
D O I
10.1038/eye.2009.77
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To compare intraocular pressure (IOP) readings between Tono-Pen tonometry and GAT, between noncontact tonometry (NCT) and GAT, and between dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT). The correlation between IOP reading and possible confounder was identified. Methods This observational cross-sectional study enrolled sixty-two healthy subjects. All IOP and ocular pulse amplitude (OPA) measurements were taken by a single ophthalmologist; mean keratometric power (MK), central corneal thickness (CCT), and lens thickness (LT) were measured by a single experienced technician. Results Stepwise multiple regression analysis indicated that GAT (P=0.017) and DCT (P=0.002) readings correlated positively with MK; GAT, NCT, and Tono-Pen readings correlated positively with CCT (P<0.05); NCT (P=0.035), and DCT (P=0.016) readings correlated negatively with LT; GAT (P=0.006) and Tono-Pen (P=0.009) readings correlated positively with OPA. Conclusions The K, CCT, LT, and OPA are confounders in tonometry readings. Eye (2009) 23, 1582-1588; doi:10.1038/eye.2009.77; published online 1 May 2009
引用
收藏
页码:1582 / 1588
页数:7
相关论文
共 50 条
  • [1] Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry
    S-Y Hsu
    M-M Sheu
    A-H Hsu
    K-Y Wu
    J-I Yeh
    J-N Tien
    R-K Tsai
    Eye, 2009, 23 : 1582 - 1588
  • [2] Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas
    Kontadakis, George A.
    Pennos, Alexandros
    Pentari, Iro
    Kymionis, George D.
    Pallikaris, Ioannis G.
    Ginis, Harilaos
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2020, 12
  • [3] Comparison of Scleral Tono-Pen Intraocular Pressure Measurements with Goldmann Applanation Tonometry
    Badakere, Swathi Vallabh
    Choudhari, Nikhil S.
    Rao, Harsha L.
    Chary, C. Raghava
    Garudadri, Chandra Sekhar
    Senthil, Sirisha
    OPTOMETRY AND VISION SCIENCE, 2018, 95 (02) : 129 - 135
  • [4] Comparison of Goldmann applanation tonometry,, rebound tonometry and dynamic contour tonometry in normal and glaucomatous eyes
    Ozcura, Fatih
    Yildirim, Nilgun
    Sahin, Afsun
    Colak, Ertugrul
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (02) : 299 - 304
  • [5] Assessment of Factors Affecting the Difference in Intraocular Pressure Measurements Between Dynamic Contour Tonometry and Goldmann Applanation Tonometry
    Wang, Jing
    Cayer, Marie-Michelle
    Descovich, Denise
    Kamdeu-Fansi, Alvine
    Harasymowycz, Paul J.
    Li, Gisele
    Lesk, Mark R.
    JOURNAL OF GLAUCOMA, 2011, 20 (08) : 482 - 487
  • [6] Comparison of Intraocular Pressure Measurements Between Goldmann Applanation Tonometry and Reichert 7 Noncontact Tonometry
    Gungor, Sirel G.
    Akman, Ahmet
    Yazici, Ayse C.
    JOURNAL OF GLAUCOMA, 2015, 24 (06) : 438 - 441
  • [7] Intraocular pressure measurement - Comparison of dynamic contour tonometry and Goldmann applanation tonometry
    Schneider, E
    Grehn, F
    JOURNAL OF GLAUCOMA, 2006, 15 (01) : 2 - 6
  • [8] Dynamic contour tonometry and Goldmann applanation tonometry: correlation with intracameral assessment of intraocular pressure
    Riva, Ivano
    Quaranta, Luciano
    Russo, Andrea
    Katsanos, Andreas
    Rulli, Eliana
    Floriani, Irene
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (01) : 55 - 62
  • [9] Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry
    J Y F Ku
    H V Danesh-Meyer
    J P Craig
    G D Gamble
    C N J McGhee
    Eye, 2006, 20 : 191 - 198
  • [10] Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry
    Ku, JYF
    Danesh-Meyer, HV
    Craig, JP
    Gamble, GD
    McGhee, CNJ
    EYE, 2006, 20 (02) : 191 - 198