An on-line pre-concentration system for determination of cadmium in drinking water using FAAS

被引:37
|
作者
dos Santos, Walter N. L. [1 ]
Costa, Jorge L. O.
Araujo, Rennan G. O.
de Jesus, Djane S.
Costa, Antonio C. S.
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[2] Ctr Fed Educ Tecnol Bahia, BR-40300010 Salvador, BA, Brazil
关键词
cadmium determination; drinking water; FAAS; pre-concentration;
D O I
10.1016/j.jhazmat.2006.03.046
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the present paper, a minicolumn of polyurethane foam loaded with 4-(2-pyridylazo)-resorcinol (PAR) is proposed as pre-concentration system for cadmium determination in drinking water samples by flame atomic absorption spectrometry. The optimization step was performed using two-level full factorial design and Doehlert matrix, involving the variables: sampling flow rate, elution concentration, buffer concentration and pH. Using the established experimental conditions in the optimization step of: pH 8.2, sampling flow rate 8.5 mL min(-1), buffer concentration 0.05 mol L-1 and elution concentration of 1.0 mol L-1, this system allows the determination of cadmium with detection limit (LD) (3 sigma/S) of 20.0ng L-1 and quantification limit (LQ) (10 sigma/S) of 64ngL(-1), precision expressed as relative standard deviation (R.S.D.) of 5.0 and 4.7% for cadmium concentration of 5.0 and 40.0 mu g L-1, respectively, and a pre-concentration factor of 158 for a sample volume of 20.0mL. The accuracy was confirmed by cadmium determination in the standard reference material, NIST SRM 1643d trace elements in natural water. This procedure was applied for cadmium determination in drinking water samples collected from Salvador City, Bahia, Brazil. For five samples analyzed, the achieved concentrations varied from 0.31 to 0.86 mu g L-1. (c) 2006 Published by Elsevier B.V.
引用
收藏
页码:1357 / 1361
页数:5
相关论文
共 50 条
  • [31] On-line coupling of derivatization with pre-concentration to determine trace levels of methotrexate
    Emara, Samy
    Masujima, Tsutomu
    Zarad, Walaa
    Kamal, Maha
    El-Bagary, Ramzia
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2013, 3 (01) : 28 - 35
  • [32] Simultaneous pre-concentration procedure for the determination of cadmium and lead in drinking water employing sequential multi-element flame atomic absorption spectrometry
    Portugal, Lindomar A.
    Ferreira, Hadla S.
    dos Santos, Walter N. L.
    Ferreira, Sergio L. C.
    MICROCHEMICAL JOURNAL, 2007, 87 (01) : 77 - 80
  • [33] An on-line system for preconcentration and determination of lead in wine samples by FAAS
    Lemos, VA
    de la Guardia, M
    Ferreira, SLC
    TALANTA, 2002, 58 (03) : 475 - 480
  • [34] Application of Modified Organo-Nanoclay as the Sorbent for Zinc Determination by FAAS: An Optimization Study of an Online Pre-concentration System
    Mostafa Khajeh
    Biological Trace Element Research, 2012, 145 : 118 - 125
  • [35] Application of Modified Organo-Nanoclay as the Sorbent for Zinc Determination by FAAS: An Optimization Study of an Online Pre-concentration System
    Khajeh, Mostafa
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2012, 145 (01) : 118 - 125
  • [36] Spectrophotometric Determination of Ultra trace Tri & Hexavalent Chromium by Using on-line Flow Injection Analysis with Dual Pre-concentration Column
    Jung, Sung-woon
    Lim, Hyun-woo
    Kang, Chul-ho
    Choi, Yong-wook
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2011, 32 (09) : 3437 - 3442
  • [37] Application of three-variables Doehlert matrix for optimisation of an on-line pre-concentration system for zinc determination in natural water samples by flame atomic absorption spectrometry
    dos Santos, WNL
    Santos, CMC
    Ferreira, SLC
    MICROCHEMICAL JOURNAL, 2003, 75 (03) : 211 - 221
  • [38] On-line and dual pre-concentration technique for large volume injection in capillary electrophoresis
    Li, Y
    He, YZ
    Hu, YY
    Wang, L
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (02) : 248 - 250
  • [39] Determination of arsenic in foods by flow injection on-line sorption pre-concentration with hydride generation atomic fluorescence spectrometry
    Li, N.
    Fang, G.
    Zhao, L.
    Wang, S.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (06): : 839 - 846
  • [40] A pre-concentration procedure using cloud point extraction for the determination of uranium in natural water
    Ferreira, HS
    Bezerra, MD
    Ferreira, SLC
    MICROCHIMICA ACTA, 2006, 154 (1-2) : 163 - 167