An on-line pre-concentration system for determination of cadmium in drinking water using FAAS

被引:37
|
作者
dos Santos, Walter N. L. [1 ]
Costa, Jorge L. O.
Araujo, Rennan G. O.
de Jesus, Djane S.
Costa, Antonio C. S.
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[2] Ctr Fed Educ Tecnol Bahia, BR-40300010 Salvador, BA, Brazil
关键词
cadmium determination; drinking water; FAAS; pre-concentration;
D O I
10.1016/j.jhazmat.2006.03.046
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the present paper, a minicolumn of polyurethane foam loaded with 4-(2-pyridylazo)-resorcinol (PAR) is proposed as pre-concentration system for cadmium determination in drinking water samples by flame atomic absorption spectrometry. The optimization step was performed using two-level full factorial design and Doehlert matrix, involving the variables: sampling flow rate, elution concentration, buffer concentration and pH. Using the established experimental conditions in the optimization step of: pH 8.2, sampling flow rate 8.5 mL min(-1), buffer concentration 0.05 mol L-1 and elution concentration of 1.0 mol L-1, this system allows the determination of cadmium with detection limit (LD) (3 sigma/S) of 20.0ng L-1 and quantification limit (LQ) (10 sigma/S) of 64ngL(-1), precision expressed as relative standard deviation (R.S.D.) of 5.0 and 4.7% for cadmium concentration of 5.0 and 40.0 mu g L-1, respectively, and a pre-concentration factor of 158 for a sample volume of 20.0mL. The accuracy was confirmed by cadmium determination in the standard reference material, NIST SRM 1643d trace elements in natural water. This procedure was applied for cadmium determination in drinking water samples collected from Salvador City, Bahia, Brazil. For five samples analyzed, the achieved concentrations varied from 0.31 to 0.86 mu g L-1. (c) 2006 Published by Elsevier B.V.
引用
收藏
页码:1357 / 1361
页数:5
相关论文
共 50 条
  • [11] Flow injection on-line double micro-column with chelating resin pre-concentration system for Cu, Pb, Cd and Mn determination by FAAS
    Chen, SY
    Sun, M
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2001, 21 (03) : 377 - 381
  • [12] Determination of selenite and selenate in drinking water: a fully automatic on-line separation/pre-concentration system coupled to electrothermal atomic spectrometry with permanent chemical modifiers
    Stripeikis, J
    Pedro, J
    Bonivardi, A
    Tudino, M
    ANALYTICA CHIMICA ACTA, 2004, 502 (01) : 99 - 105
  • [13] An automated on-line flow system for the pre-concentration and determination of lead by flame atomic absorption spectrometry
    Ferreira, SLC
    Lemos, VA
    Santelli, RE
    Ganzarolli, E
    Curtius, AJ
    MICROCHEMICAL JOURNAL, 2001, 68 (01) : 41 - 46
  • [14] Application of Box-Behnken design in the optimisation of an on-line pre-concentration system using knotted reactor for cadmium determination by flame atomic absorption spectrometry
    Souza, AS
    dos Santos, WNL
    Ferreira, SLC
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (05) : 737 - 742
  • [15] Determination of total inorganic arsenic in water using on-line pre-concentration and hydride-generation atomic absorption spectrometry
    Bortoleto, GG
    Cadore, S
    TALANTA, 2005, 67 (01) : 169 - 174
  • [16] Determination of cadmium in alcohol fuel using Moringa oleifera seeds as a biosorbent in an on-line system coupled to FAAS
    Alves, Vanessa Nunes
    Mosquetta, Rafael
    Melo Coelho, Nivia Maria
    Bianchin, Joyce Nunes
    Di Pietro Roux, Kalya Cravo
    Martendal, Edmar
    Carasek, Eduardo
    TALANTA, 2010, 80 (03) : 1133 - 1138
  • [17] On-line sample pre-concentration in microfluidic devices: A review
    Giordano, Braden C.
    Burgi, Dean S.
    Hart, Sean J.
    Terray, Alex
    ANALYTICA CHIMICA ACTA, 2012, 718 : 11 - 24
  • [18] On-line pre-concentration and simultaneous stripping voltammetry analysis of airborne zinc, lead and cadmium traces
    Belostotsky, I
    Gridin, VV
    Schechter, I
    Yarnitzky, CN
    REVIEWS IN ANALYTICAL CHEMISTRY, 2000, 19 (3-4): : 191 - 200
  • [19] Application of polyurethane foam loaded with BTAC in an on-line preconcentration system: cadmium determination by FAAS
    Lemos, VA
    Santelli, RE
    de Carvalho, MS
    Ferreira, SLC
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (09) : 1497 - 1502
  • [20] On-line pre-concentration of atrazine by antibody immobilization capillary electrophoresis
    Little, MK
    Crawley, CD
    ANALYTICA CHIMICA ACTA, 2002, 464 (01) : 25 - 35