An on-line pre-concentration system for determination of cadmium in drinking water using FAAS

被引:37
|
作者
dos Santos, Walter N. L. [1 ]
Costa, Jorge L. O.
Araujo, Rennan G. O.
de Jesus, Djane S.
Costa, Antonio C. S.
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[2] Ctr Fed Educ Tecnol Bahia, BR-40300010 Salvador, BA, Brazil
关键词
cadmium determination; drinking water; FAAS; pre-concentration;
D O I
10.1016/j.jhazmat.2006.03.046
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the present paper, a minicolumn of polyurethane foam loaded with 4-(2-pyridylazo)-resorcinol (PAR) is proposed as pre-concentration system for cadmium determination in drinking water samples by flame atomic absorption spectrometry. The optimization step was performed using two-level full factorial design and Doehlert matrix, involving the variables: sampling flow rate, elution concentration, buffer concentration and pH. Using the established experimental conditions in the optimization step of: pH 8.2, sampling flow rate 8.5 mL min(-1), buffer concentration 0.05 mol L-1 and elution concentration of 1.0 mol L-1, this system allows the determination of cadmium with detection limit (LD) (3 sigma/S) of 20.0ng L-1 and quantification limit (LQ) (10 sigma/S) of 64ngL(-1), precision expressed as relative standard deviation (R.S.D.) of 5.0 and 4.7% for cadmium concentration of 5.0 and 40.0 mu g L-1, respectively, and a pre-concentration factor of 158 for a sample volume of 20.0mL. The accuracy was confirmed by cadmium determination in the standard reference material, NIST SRM 1643d trace elements in natural water. This procedure was applied for cadmium determination in drinking water samples collected from Salvador City, Bahia, Brazil. For five samples analyzed, the achieved concentrations varied from 0.31 to 0.86 mu g L-1. (c) 2006 Published by Elsevier B.V.
引用
收藏
页码:1357 / 1361
页数:5
相关论文
共 50 条
  • [1] Automatic on-line pre-concentration system using a knotted reactor for the FAAS determination of lead in drinking water
    Souza, Anderson S.
    Brandao, Geovani C.
    dos Santos, Walter N. L.
    Lemos, Valfredo A.
    Ganzarolli, Edgard M.
    Bruns, Roy E.
    Ferreira, Sergio L. C.
    JOURNAL OF HAZARDOUS MATERIALS, 2007, 141 (03) : 540 - 545
  • [2] Use of Al2O3 in an automated on-line pre-concentration system for determination of cadmium(II) by FAAS
    Souza, Erica Silva
    Martins, Amarildo Otavio
    Fajardo, Humberto Vieira
    Dias Probst, Luiz Fernando
    Carasek, Eduardo
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 150 (02) : 328 - 334
  • [3] On-line pre-concentration system for vanadium determination in drinking water using flow injection-inductively coupled plasma atomic emission spectrometry
    Wuilloud, RG
    Salonia, JA
    Gásquez, JA
    Olsina, RA
    Martinez, LD
    ANALYTICA CHIMICA ACTA, 2000, 420 (01) : 73 - 79
  • [4] On-line preconcentration system with faas detection for determination of cadmium
    Pyrzynska, K
    Szelag, H
    ANALYTICAL LETTERS, 2001, 34 (12) : 2153 - 2158
  • [5] Multivariate optimization and validation studies in on-line pre-concentration system for lead determination in drinking water and saline waste from oil refinery
    dos Santos, WL
    dos Santos, CMM
    Costa, JLO
    Andrade, HMC
    Ferreira, SLC
    MICROCHEMICAL JOURNAL, 2004, 77 (02) : 123 - 129
  • [6] On-line simultaneous pre-concentration procedure for the determination of cadmium and lead in drinking water employing sequential multi-element flame atomic absorption spectrometry
    dos Santos, Walter N. L.
    Santos, Joao V. S.
    Silva, Laiana O. B.
    Araujo, Andre S.
    Lemos, Valfredo A.
    Miro, Manuel
    Ferreira, Sergio L. C.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2011, 91 (15) : 1425 - 1435
  • [7] Automated flow injection method for cadmium determination with pre-concentration and on-line reagent preparation.
    Di Nezio, MS
    Palomeque, ME
    Band, BSF
    QUIMICA NOVA, 2005, 28 (01): : 145 - 148
  • [8] On-line enrichment system for manganese determination in water samples using FAAS
    Knap, Marta
    Kilian, Krzysztof
    Pyrzynska, Krystyna
    TALANTA, 2007, 71 (01) : 406 - 410
  • [9] On-line pre-concentration of Hg in blood and urine and determination by CVAAS
    Dressler, VL
    Flores, ÉMM
    Pozebon, D
    Kaercher, LE
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) : 790 - 793
  • [10] On-line FI-preconcentration-FAAS determination of cadmium and copper in water
    Zhang, X.Y.
    Lihua Jianyan: Huaxue Fence/Physical Testing and Chemical Analysis Part B:Chemical Analysis, 2001, 37 (01):