Three-dimensional, navigator-echo MR coronary angiography in detecting stenoses of the major epicardial vessels, with conventional coronary angiography as the standard of reference

被引:48
|
作者
Sardanelli, F
Molinari, G
Zandrino, F
Balbi, M
机构
[1] Univ Genoa, Sch Med, Dept Radiol, I-16132 Genoa, Italy
[2] Univ Genoa, Sch Med, Dept Cardiol, I-16132 Genoa, Italy
关键词
coronary angiography; comparative studies; coronary vessels; diseases; MR; stenosis or obstruction; magnetic resonance (MR); three-dimensional; vascular studies;
D O I
10.1148/radiology.214.3.r00mr01808
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To test three-dimensional (3D), navigator-echo magnetic resonance (MR) coronary angiography in detecting stenoses of the coronary arteries. MATERIALS AND METHODS: Forty-two patients (age range, 50-79 years) underwent MR coronary angiography (1.5 T). A navigator-echo sequence was used. Two or three 15% overlapped transverse slabs were acquired. Data were analyzed by readers blinded to conventional coronary angiographic results. On conventional coronary angiograms, coronary arterial stenoses of 50% or greater narrowing were considered significant. On MR coronary angiograms, the major coronary vessels were subdivided into proximal (within 5 cm) and distal (beyond 5 cm) segments, except for the left main vessel. Stenoses of 50% or greater were identified on reformatted multiplanar MR coronary angiograms. RESULTS: Three MR coronary angiographic examinations were aborted because of patient claustrophobia; 39 of 39 left main, 117 of 117 proximal, and 78 of 117 distal segments were visualized. MR coronary angiography showed a sensitivity of 82% (95% CI: 73%, 91%) and a specificity of 89% (95% CI: 85%, 94%) in overall stenoses identification, of 90% (95% CI: 81%, 99%) and 90% (95% CI: 83%, 96%) for proximal segments, and of 68% (95% CI: 50%, 86%) and 81% (95% CI: 71%, 92%) for distal segments, respectively. CONCLUSION: Navigator-echo, 3D MR coronary angiography is a promising sequence for assessing coronary arterial stenoses, but further improvements are required for distal segments.
引用
收藏
页码:808 / 814
页数:7
相关论文
共 49 条
  • [31] A methodology for quantifying deformations in stented coronary arteries based on three-dimensional angiography
    Chen S.J.
    Messenger J.C.
    Carroll J.D.
    Journal of ASTM International, 2010, 7 (01):
  • [32] Partial fat-saturated contrast-enhanced three-dimensional MR angiography compared with non-fat-saturated and conventional fat-saturated MR angiography
    Hilfiker, PR
    Herfkens, RJ
    Heiss, SG
    Alley, MT
    Fleischmann, D
    Pelc, NJ
    RADIOLOGY, 2000, 216 (01) : 298 - 303
  • [33] Three-dimensional and two-dimensional quantitative coronary angiography, and their prediction of reduced fractional flow reserve
    Yong, Andy S. C.
    Ng, Austin C. C.
    Brieger, David
    Lowe, Harry C.
    Ng, Martin K. C.
    Kritharides, Leonard
    EUROPEAN HEART JOURNAL, 2011, 32 (03) : 345 - 353
  • [34] High-resolution multiphase contrast-enhanced three-dimensional MR angiography compared with two-dimensional time-of-flight MR angiography for the identification of pedal vessels
    Sharafuddin, MJ
    Stolpen, AH
    Sun, SL
    Leusner, CR
    Safvi, AA
    Hoballah, JJ
    Sharp, WJ
    Corson, JD
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (07) : 695 - 702
  • [35] Automatic gating window selection for gated three-dimensional coronary X-ray angiography
    Rasche, V
    Movassaghi, B
    Grass, M
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1050 - 1054
  • [36] Plaque volume derived from three-dimensional reconstruction of coronary angiography predicts the fractional flow reserve
    Kolozsvari, R.
    Tar, B.
    Lugosi, P.
    Santa, J.
    Beres, Z.
    Ungvari, T.
    Polgar, P.
    Koszegi, Zs.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 160 (02) : 140 - 144
  • [37] Automatic selection of the optimal cardiac phase for gated three-dimensional coronary x-ray angiography
    Rasche, V
    Movassaghi, B
    Grass, M
    Schäfer, D
    Buecker, A
    ACADEMIC RADIOLOGY, 2006, 13 (05) : 630 - 640
  • [38] Gadolinium-enhanced breath-hold three-dimensional MR angiography of the portal vein: Value of the magnetization-prepared rapid acquisition gradient-echo sequence
    Yamashita, Y
    Mitsuzaki, K
    Miyazaki, T
    Namimoto, T
    Sumi, S
    Urata, J
    Abe, Y
    Ogata, I
    Takahashi, M
    RADIOLOGY, 1996, 201 (01) : 283 - 288
  • [39] Three-dimensional magnetic resonance coronary angiography using a new blood pool contrast agent: Initial experience
    Bedaux, WLF
    Hofman, MBM
    Wielopolski, PA
    de Cock, CC
    Hoffmann, V
    Oudkerk, M
    de Feyter, PJ
    van Rossum, AC
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2002, 4 (02) : 273 - 282
  • [40] Free-Breathing Multiphase Whole-Heart Coronary MR Angiography Using Image-Based Navigators and Three-Dimensional Cones Imaging
    Wu, Holden H.
    Gurney, Paul T.
    Hu, Bob S.
    Nishimura, Dwight G.
    McConnell, Michael V.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (04) : 1083 - 1093