Comparison between Three-Capacitance, Analytical-based and Finite Element Analysis Partial Discharge Models in Condition Monitoring

被引:44
作者
Illias, H. A. [1 ]
Chen, G. [2 ]
Lewin, Paul L. [2 ]
机构
[1] Univ Malaya, Fac Engn, Dept Elect Engn, Kuala Lumpur 50603, Malaysia
[2] Univ Southampton, Tony Davies High Voltage Lab, Southampton SO17 1BJ, Hants, England
关键词
Partial discharge; electrical insulation; finite element analysis; induced charge concept; capacitance model; condition monitoring; SPHEROIDAL VOIDS; DIELECTRIC MATERIAL; STOCHASTIC-PROCESS; APPLIED VOLTAGE; INDUCED CHARGE; SIMULATION; FREQUENCY; CAVITY; PD; TRANSIENTS;
D O I
10.1109/TDEI.2016.005971
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An important and essential diagnostic tool for insulation systems in condition monitoring is partial discharge (PD) measurement. Through PD measurement, the results may be used for insulation condition assessment. However, the modelling of PD is important because it is helpful in attaining a better understanding of PD phenomenon. The physical mechanisms and critical parameters influencing PD events under various conditions of defects and stresses can be identified. The relationship between the insulation design parameters, test conditions and defect characteristics with PD activities can also be developed. There have been many researches that reported on simulation of PD events in a void in insulation material. PD models can be categorized in three models, they are the induced charge concept model, threecapacitance model and the finite element method models. Each model has its own strengths and limitations in certain aspects. Therefore, in this paper, comparative studies and simulations for various PD models that have been developed to date are reported and discussed. The disadvantages and advantages of every model are presented in details. The results from the simulation using those models were compared with the measurement data to observe their performance in terms of physical parameters values. From comparative studies between each model, the most suitable PD model can be chosen to simulate PD events depending on the requirement selected by the users.
引用
收藏
页码:99 / 109
页数:11
相关论文
共 57 条
[1]   Partial Discharges and Associated Transients: The Induced Charge Concept versus Capacitive Modeling [J].
Achillides, Zenon ;
Georghiou, George E. ;
Kyriakides, Elias .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (06) :1507-1516
[2]  
Ala G., 2011, 2011 8th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED 2011), P451, DOI 10.1109/DEMPED.2011.6063662
[3]  
ALSHEIKHLY A, 1992, PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS, P176, DOI 10.1109/ICSD.1992.224982
[4]  
[Anonymous], 2005, P NORD INS S TRONDH
[5]   Partial discharge diagnostics of micro cavities in epoxy insulating materials and their modelling [J].
Budde, M. ;
Kurrat, M. .
CONFERENCE RECORD OF THE 2008 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 2008, :369-372
[6]  
Budde M., 2009, INT S HIGH VOLT ENG, P369
[7]   Modeling memory phenomena for partial discharge processes in insulation cavities [J].
Cavallini, A ;
Ciani, R ;
Conti, M ;
Morshuis, PFH ;
Montanari, GC .
2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, :723-727
[8]   Diagnosis of EHV and HV Transformers Through an Innovative Partial-Discharge-Based Technique [J].
Cavallini, Andrea ;
Chen, Xiaolin ;
Montanari, Gian Carlo ;
Ciani, Fabio .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) :814-824
[9]  
Chen G., 2008, INT C COND MON DIAGN
[10]   New diagnosis approach to epoxy resin transformer partial discharge using acoustic technology [J].
Chen, LJ ;
Tsao, TP ;
Lin, YH .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (04) :2501-2508