Lung function testing and assessment of distal airways in asthma
被引:8
|
作者:
Garcia, G.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Paris 11, Hop Antoine Beclere, AP HP, Serv Explorat Fonct, Clamart, FranceUniv Paris 11, Hop Antoine Beclere, AP HP, Serv Explorat Fonct, Clamart, France
Garcia, G.
[1
]
Perez, T.
论文数: 0引用数: 0
h-index: 0
机构:
CHRU Lille, Hop Albert Calmette, Serv Explorat Fonct Resp, Lille, France
CHRU Lille, Hop Albert Calmette, Serv Pneumol & Immunoallergol, Lille, FranceUniv Paris 11, Hop Antoine Beclere, AP HP, Serv Explorat Fonct, Clamart, France
Perez, T.
[2
,3
]
Mahut, B.
论文数: 0引用数: 0
h-index: 0
机构:
Cabinet Berma, Antony, France
Hop Necker Enfants Malad, AP HP, Serv Pneumoallergol Pediat, Paris, FranceUniv Paris 11, Hop Antoine Beclere, AP HP, Serv Explorat Fonct, Clamart, France
Mahut, B.
[4
,5
]
机构:
[1] Univ Paris 11, Hop Antoine Beclere, AP HP, Serv Explorat Fonct, Clamart, France
[2] CHRU Lille, Hop Albert Calmette, Serv Explorat Fonct Resp, Lille, France
[3] CHRU Lille, Hop Albert Calmette, Serv Pneumol & Immunoallergol, Lille, France
[4] Cabinet Berma, Antony, France
[5] Hop Necker Enfants Malad, AP HP, Serv Pneumoallergol Pediat, Paris, France
Introduction Small airways are defined (in humans) as those <2mm in diameter. Background They were originally described as the "quiet zone" of the lungs contributing less than 10% of the total resistance to airflow. Pulmonary function tests remain the most used method to assess distal airway flow limitation. Viewpoints However, these tests are limited in adults and also in children because MEF25-75% and FEF50% are highly variable spirometric indices and they depend on vital capacity, which increases with expiratory time in obstructed subjects. There is a need for promising non invasive new tools like the forced oscillation technique to measure resistance. The increased availability of the exhaled fraction of nitric oxide (FeNO) measurement means that this method is accessible and attractive. Conclusion The production of nitric oxide (NO) can be assessed by measuring the fraction of NO during a prolonged expiration (FENO) or by estimating other parameters of NO exchange including the alveolar NO concentration (CalvNO) and may provide information about small airway inflammation and assist the optimal control of the disease.
机构:
Osaka City Univ, Dept Resp Med, Grad Sch Med, Abeno Ku, Osaka 5458585, JapanOsaka City Univ, Dept Resp Med, Grad Sch Med, Abeno Ku, Osaka 5458585, Japan
Kanazawa, Hiroshi
Kyoh, Shigenori
论文数: 0引用数: 0
h-index: 0
机构:
Osaka City Univ, Dept Resp Med, Grad Sch Med, Abeno Ku, Osaka 5458585, JapanOsaka City Univ, Dept Resp Med, Grad Sch Med, Abeno Ku, Osaka 5458585, Japan
Kyoh, Shigenori
Asai, Kazuhisa
论文数: 0引用数: 0
h-index: 0
机构:
Osaka City Univ, Dept Resp Med, Grad Sch Med, Abeno Ku, Osaka 5458585, JapanOsaka City Univ, Dept Resp Med, Grad Sch Med, Abeno Ku, Osaka 5458585, Japan
Asai, Kazuhisa
Hirata, Kazuto
论文数: 0引用数: 0
h-index: 0
机构:
Osaka City Univ, Dept Resp Med, Grad Sch Med, Abeno Ku, Osaka 5458585, JapanOsaka City Univ, Dept Resp Med, Grad Sch Med, Abeno Ku, Osaka 5458585, Japan