Quantification of iopamidol multi-site chemical exchange properties for ratiometric chemical exchange saturation transfer (CEST) imaging of pH

被引:54
|
作者
Sun, Phillip Zhe [1 ,2 ]
Longo, Dario Livio [3 ,4 ]
Hu, Wei [5 ]
Xiao, Gang [5 ,6 ]
Wu, Renhua [5 ]
机构
[1] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Dept Radiol, Charlestown, MA 02114 USA
[2] Harvard Univ, Sch Med, Charlestown, MA USA
[3] Univ Turin, Ctr Mol Biotechnol, Inst Biostruct & Bioimages CNR, Turin, Italy
[4] Univ Turin, Mol Imaging Ctr, Turin, Italy
[5] Shantou Univ, Coll Med, Affiliated Hosp 2, Dept Radiol, Shantou, Peoples R China
[6] Hanshan Normal Univ, Dept Math & Appl Math, Chaozhou, Peoples R China
关键词
chemical exchange saturation transfer (CEST); iopamidol; MRI; pH; PROTON FRACTION RATIO; IN-VIVO; CONTRAST AGENTS; QUANTITATIVE DESCRIPTION; INTRACELLULAR PH; PARACEST AGENTS; MRI; TIME; OPTIMIZATION; RELAXATION;
D O I
10.1088/0031-9155/59/16/4493
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
pH-sensitive chemical exchange saturation transfer (CEST) MRI holds great promise for in vivo applications. However, the CEST effect depends on not only exchange rate and hence pH, but also on the contrast agent concentration, which must be determined independently for pH quantification. Ratiometric CEST MRI normalizes the concentration effect by comparing CEST measurements of multiple labile protons to simplify pH determination. Iopamidol, a commonly used x-ray contrast agent, has been explored as a ratiometric CEST agent for imaging pH. However, iopamidol CEST properties have not been solved, determination of which is important for optimization and quantification of iopamidol pH imaging. Our study numerically solved iopamidol multi-site pH-dependent chemical exchange properties. We found that iopamidol CEST MRI is suitable for measuring pH between 6 and 7.5 despite that T-1 and T-2 measurements varied substantially with pH and concentration. The pH MRI precision decreased with pH and concentration. The standard deviation of pH determined from MRI was 0.2 and 0.4 pH unit for 40 and 20 mM iopamidol solution of pH 6, and it improved to be less than 0.1 unit for pH above 7. Moreover, we determined base-catalyzed chemical exchange for 2-hydrooxypropanamido (k(sw) = 1.2*10(pH-4.1)) and amide (k(sw) = 1.2*10(pH-4.6)) protons that are statistically different from each other (P < 0.01, ANCOVA), understanding of which should help guide in vivo translation of iopamidol pH imaging.
引用
收藏
页码:4493 / 4504
页数:12
相关论文
共 50 条
  • [31] Chemical exchange saturation transfer fingerprinting for exchange rate quantification
    Zhou, Zhengwei
    Han, Pei
    Zhou, Bill
    Christodoulou, Anthony G.
    Shaw, Jaime L.
    Deng, Zixin
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (04) : 1352 - 1363
  • [32] Application of Chemical Exchange Saturation Transfer (CEST) MRI for Endogenous Contrast at 7 Tesla
    Dula, Adrienne N.
    Smith, Seth A.
    Gore, John C.
    JOURNAL OF NEUROIMAGING, 2013, 23 (04) : 526 - 532
  • [33] Molecular imaging of tumors and metastases using chemical exchange saturation transfer (CEST) MRI
    Rivlin, Michal
    Horev, Judith
    Tsarfaty, Ilan
    Navon, Gil
    SCIENTIFIC REPORTS, 2013, 3
  • [34] Chemical Exchange Saturation Transfer (CEST) Imaging: Description of Technique and Potential Clinical Applications
    Kogan F.
    Hariharan H.
    Reddy R.
    Current Radiology Reports, 2013, 1 (2) : 102 - 114
  • [35] Signature of protein unfolding in chemical exchange saturation transfer imaging
    Goerke, Steffen
    Zaiss, Moritz
    Kunz, Patrick
    Klika, Karel D.
    Windschuh, Johannes D.
    Mogk, Axel
    Bukau, Bernd
    Ladd, Mark E.
    Bachert, Peter
    NMR IN BIOMEDICINE, 2015, 28 (07) : 906 - 913
  • [36] Fast Multislice pH-Weighted Chemical Exchange Saturation Transfer (CEST) MRI With Unevenly Segmented RF Irradiation
    Sun, Phillip Zhe
    Cheung, Jerry S.
    Wang, Enfeng
    Benner, Thomas
    Sorensen, A. Gregory
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (02) : 588 - 594
  • [37] Simultaneous determination of labile proton concentration and exchange rate utilizing optimal RF power: Radio frequency power (RFP) dependence of chemical exchange saturation transfer (CEST) MRI
    Sun, Phillip Zhe
    JOURNAL OF MAGNETIC RESONANCE, 2010, 202 (02) : 155 - 161
  • [38] On the origins of chemical exchange saturation transfer ( CEST) contrast in tumors at 9.4 T
    Xu, Junzhong
    Zaiss, Moritz
    Zu, Zhongliang
    Li, Hua
    Xie, Jingping
    Gochberg, Daniel F.
    Bachert, Peter
    Gore, John C.
    NMR IN BIOMEDICINE, 2014, 27 (04) : 406 - 416
  • [39] Multi-angle ratiometric approach to measure chemical exchange in amide proton transfer imaging
    Zu, Zhongliang
    Janve, Vaibhav A.
    Li, Ke
    Does, Mark D.
    Gore, John C.
    Gochberg, Daniel F.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) : 711 - 719
  • [40] Assessment of a clinically feasible Bayesian fitting algorithm using a simplified description of Chemical Exchange Saturation Transfer (CEST) imaging
    Kujawa, Aaron
    Kim, Mina
    Demetriou, Eleni
    Anemone, Annasofia
    Longo, Dario Livio
    Zaiss, Moritz
    Golay, Xavier
    JOURNAL OF MAGNETIC RESONANCE, 2019, 300 : 120 - 134