Comparison of Accuracy of Axial Slices Versus Short-Axis Slices for Measuring Ventricular Volumes by Cardiac Magnetic Resonance in Patients With Corrected Tetralogy of Fallot

被引:77
|
作者
Fratz, Sohrab [1 ]
Schuhbaeck, Annika [1 ]
Buchner, Christine [1 ]
Busch, Raymonde [2 ]
Meierhofer, Christian [1 ]
Martinoff, Stefan [3 ]
Hess, John [1 ]
Stern, Heiko [1 ]
机构
[1] Tech Univ Munich, Deutsch Herzzentrum Munchen, Dept Paediat Cardiol & Congenital Heart Dis, Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Inst Med Stat, D-8000 Munich, Germany
[3] Tech Univ Munich, Deutsch Herzzentrum Munchen, Dept Radiol, D-8000 Munich, Germany
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2009年 / 103卷 / 12期
关键词
CONGENITAL HEART-DISEASE; MASS; CMR; REPRODUCIBILITY; QUANTIFICATION; TOMOGRAPHY; PROTOCOLS; OPERATION; SOCIETY; FLOW;
D O I
10.1016/j.amjcard.2009.02.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The best method to measure right (RV) and left (LV) ventricle volumes of patients with corrected tetralogy of Fallot is considered cardiac magnetic resonance (CMR). However, to date, no standard protocol to measure RV volumes by CMR exists. RV volumes can be measured from a stack of short-axis slices or a stack of axial slices through the patient's chest. Therefore, the aim of this study was to determine whether short-axis or axial slices are more reliable for routine measurement of RV and LV volumes in patients with corrected tetralogy of Fallot. We studied consecutive patients with corrected tetralogy of Fallot (n = 46) undergoing routine CMR. The end-diastolic and end-systolic RV and LV volumes were measured by 2 investigators unaware of the results of the other measurements using short-axis and axial slices, and the inter- and intraobserver variances were compared. The design of the study was based on the Standards for Reporting of Diagnostic Accuracy. Interobserver variance was significantly smaller using axial slices than using short-axis slices for the RV end-systolic volumes (127.9%(2) vs 315. 1%(2); p = 0.003), LV end-diastolic volumes (11.4%(2) vs 36.1%(2); p <0.001), and LV end-systolic volumes (31.9%(2) vs 176.1%(2); p <0.001). Intraobserver variance was significantly smaller using axial slices than using short-axis slices for the RV end-diastolic volumes (26.7%(2) vs 51.1%(2); p = 0.032), LV end-diastolic volumes (11.0%(2) vs 23.5%(2); p = 0.012), and LV end-systolic volumes (34.3%(2) vs 86.1%(2); p = 0.003). In conclusion, axial slices are more reproducible than short-axis slices for measuring ventricular volumes of patients with corrected tetralogy of Fallot by CNM. (C) 2009 Elsevier Inc. (Am J Cardiol 2009;103:1764-1769)
引用
收藏
页码:1764 / 1769
页数:6
相关论文
共 28 条
  • [21] Quantitative Assessment of Right Ventricular Volumes and Ejection Fraction in Patients with Left Ventricular Systolic Dysfunction by Real Time Three-Dimensional Echocardiography versus Cardiac Magnetic Resonance Imaging
    Kim, Jiwon
    Cohen, Scott B.
    Atalay, Michael K.
    Maslow, Andrew D.
    Poppas, Athena
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (05): : 805 - 812
  • [22] Comparison of Magnetic Resonance Imaging Versus Doppler Echocardiography for the Evaluation of Left Ventricular Diastolic Function in Patients With Cardiac Amyloidosis
    Rubinshtein, Ronen
    Glockner, James F.
    Feng, DaLi
    Araoz, Philip A.
    Kirsch, Jacobo
    Syed, Imran S.
    Oh, Jae K.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (05): : 718 - 723
  • [23] Surgical and transcatheter pulmonary valve replacement in patients with repaired tetralogy of Fallot: cardiac magnetic resonance imaging characteristics and morphology of right ventricular outflow tract
    Ozkok, Sercin
    Ciftci, Hatice Ozge
    Kose, Kevser Banu
    Yucel, Ilker Kemal
    Sasmazel, Ahmet
    Celebi, Ahmet
    Pekkan, Kerem
    PEDIATRIC RADIOLOGY, 2023, 53 (09) : 1863 - 1873
  • [24] Surgical and transcatheter pulmonary valve replacement in patients with repaired tetralogy of Fallot: cardiac magnetic resonance imaging characteristics and morphology of right ventricular outflow tract
    Sercin Ozkok
    Hatice Ozge Ciftci
    Kevser Banu Kose
    Ilker Kemal Yucel
    Ahmet Sasmazel
    Ahmet Celebi
    Kerem Pekkan
    Pediatric Radiology, 2023, 53 : 1863 - 1873
  • [25] Accuracy of Right and Left Ventricular Functional Assessment by Short-Axis vs Axial Cine Steady-State Free-Precession Magnetic Resonance Imaging: Intrapatient Correlation With Main Pulmonary Artery and Ascending Aorta Phase-Contrast Flow Measurements
    James, Susan H.
    Wald, Rachel
    Wintersperger, Bernd J.
    Jimenez-Juan, Laura
    Deva, Djeven
    Crean, Andrew M.
    Elsie Nguyen
    Paul, Narinder S.
    Ley, Sebastian
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (03): : 213 - 219
  • [26] Single-Beat Versus Multibeat Real-Time 3D Echocardiography for Assessing Left Ventricular Volumes and Ejection Fraction A Comparison Study With Cardiac Magnetic Resonance
    Macron, Laurent
    Lim, Pascal
    Bensaid, Alexandre
    Nahum, Julien
    Dussault, Caroline
    Mitchell-Heggs, Laurens
    Dubois-Rande, Jean-Luc
    Deux, Jean-Francois
    Gueret, Pascal
    CIRCULATION-CARDIOVASCULAR IMAGING, 2010, 3 (04) : 450 - 455
  • [27] Does limited right ventriculotomy prevent right ventricular dilatation and dysfunction in patients who undergo transannular repair of tetralogy of Fallot? Matched comparison of magnetic resonance imaging parameters with conventional right ventriculotomy long-term after repair
    Lee, Cheul
    Lee, Chang-Ha
    Kwak, Jae Gun
    Kim, Seong-Ho
    Shim, Woo-Sup
    Lee, Sang Yun
    Baek, Jae Suk
    Jang, So-Ick
    Kim, Yang Min
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (03): : 889 - 895
  • [28] The impacts of severe perfusion defects, akinetic/dyskinetic segments, and viable myocardium on the accuracy of volumes and LVEF measured by gated 99mTc-MIBI SPECT and gated 18F-FDG PET in patients with left ventricular aneurysm: cardiac magnetic resonance imaging as the reference
    Wei, Hongxing
    Tian, Congna
    Schindler, Thomas H.
    Qiu, Mei
    Lu, Minjie
    Shen, Rui
    Tian, Yueqin
    Zhao, Shi-hua
    Zhang, Xiaoli
    JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (06) : 1230 - 1244