Operational results of an intermittent absorption cooling unit

被引:16
|
作者
El-Ghalban, AR [1 ]
机构
[1] Menufia Univ, Fac Engn, Dept Power Mech Engn, Shebin El Kaum, Egypt
关键词
cooling; intermittent absorption unit; water-lithium chloride solution;
D O I
10.1002/er.822
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The concept of solar cooling is appealing because the cooling load is in phase with the intensity of solar energy. Many system arrangements or cycles are employed to achieve solar cooling, such as Absorption, desiccant or Rankine-vapour compression systems. The technical feasibility of driving an absorption-cooling unit by a low-temperature heat source (such as solar energy using a simple flat-plate collector) for air-conditioning applications is investigated in this work. This study aims to design and construct a prototype for an intermittent absorption refrigeration system and to examine its implementation. The operating characteristics of the considered unit are extensively investigated. In order to accomplish this strategy, the prototype was integrated in a test rig designed for this purpose and equipped with the necessary measuring instruments to determine the required operating criteria of the unit. The energy added or extracted to or from the different unit components is calculated and the system performance is analysed. The C.O.P of the unit is found to be 19% which is 2% lower than the designed value, which could be regarded as an encouraging result for more studies in this field. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:825 / 835
页数:11
相关论文
共 50 条
  • [21] Experimental investigation of a natural zeolite-water adsorption cooling unit
    Solmus, Ismail
    Kaftanoglu, Bilgin
    Yamali, Cemil
    Baker, Derek
    APPLIED ENERGY, 2011, 88 (11) : 4206 - 4213
  • [22] Influence of vapor absorption cooling on humidification-dehumidification (HDH) desalination
    Chiranjeevi, C.
    Srinivas, T.
    ALEXANDRIA ENGINEERING JOURNAL, 2016, 55 (03) : 1961 - 1967
  • [23] Exergy and structural analysis of an absorption cooling cycle and the effect of efficiency parameters
    Boer, D
    Medrano, M
    Nogués, M
    Proceedings of ECOS 2005, Vols 1-3: SHAPING OUR FUTURE ENERGY SYSTEMS, 2005, : 337 - 344
  • [24] Feasibility studies on alternative aqueous salt mixture in vapour absorption cooling
    Banu, P. S. Arshi
    Sivamani, Seralathan
    Premkumar, T. Micha
    Solomon, Gnanadurai Ravikumar
    MATERIALS TODAY-PROCEEDINGS, 2020, 33 : 1121 - 1127
  • [25] Design of a Multigenerational System With Absorption Cooling for a Residential Community: A Case Study
    Bolt, Andre
    Chea, Branson
    Dincer, Ibrahim
    Agelin-Chaab, Martin
    Rosen, Marc
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2021, 143 (06):
  • [26] Results of the investigation of microclimate created by radiant heating/cooling system
    Paulauskaite, Sabina
    Valancius, Kestutis
    Parfentieva, Natalia
    7TH INTERNATIONAL CONFERENCE ENVIRONMENTAL ENGINEERING, VOLS 1-3, 2008, : 859 - +
  • [27] Post exercise changes in compartmental body temperature accompanying intermittent cold water cooling in the hyperthermic horse
    Marlin, DJ
    Scott, CM
    Roberts, CA
    Casas, I
    Holah, G
    Schroter, RC
    EQUINE VETERINARY JOURNAL, 1998, 30 (01) : 28 - 34
  • [28] Experimental investigation on intermittent spray cooling and toxic hazards of lithium-ion battery thermal runaway
    Zhang, Lin
    Duan, Qiangling
    Meng, Xiangdong
    Jin, Kaiqiang
    Xu, Jiajia
    Sun, Jinhua
    Wang, Qingsong
    ENERGY CONVERSION AND MANAGEMENT, 2022, 252
  • [29] Feasibility limits and performance of an absorption cooling machine using light alkane mixtures
    Dardour, H.
    Mazouz, S.
    Reneaume, J. -M.
    Cezac, P.
    Bourouis, M.
    Bellagi, A.
    APPLIED THERMAL ENGINEERING, 2015, 78 : 24 - 29
  • [30] Experimental investigation of a LiCl-water open absorption system for cooling and dehumidification
    Gommed, K
    Grossman, G
    Ziegler, F
    PROCEEDINGS OF THE INTERNATIONAL SORPTION HEAT PUMP CONFERENCE, 2002, : 391 - 396