Multi-parametric quantification of tricuspid regurgitation using cardiovascular magnetic resonance: A comparison to echocardiography

被引:13
|
作者
Medvedofsky, Diego [1 ]
Leon Jimenez, Javier [2 ]
Addetia, Karima [1 ]
Singh, Amita [1 ]
Lang, Roberto M. [1 ]
Mor-Avi, Victor [1 ]
Patela, Amit R. [1 ]
机构
[1] Univ Chicago, Med Ctr, Dept Med, Chicago, IL 60637 USA
[2] Complejo Hosp Univ Huelva, Huelva, Spain
关键词
Tricuspid regurgitation; Quantification; Cardiac magnetic resonance imaging; Cardiac imaging; Valvular heart disease; VALVULAR HEART-DISEASE; MITRAL REGURGITATION; QUANTITATION; VELOCITY; VOLUME; MRI;
D O I
10.1016/j.ejrad.2016.11.025
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Velocity-encoding is used to quantify tricuspid regurgitation (TR) by cardiovascular magnetic resonance (CMR), but requires additional dedicated imaging. We hypothesized that size and signal intensity (SI) of the cross-sectional TR jet area in the right atrium in short-axis steady-state free-precession images could be used to assess TR severity. Methods: We studied 61 patients with TR, who underwent CMR and echocardiography within 24 h. TR severity was determined by vena contracta: severe (N = 20), moderate or mild (N = 41). CMR TR jet area and normalized SI were measured in the plane and frame that depicted maximum area. ROC analysis was performed in 21/61 patients to determine diagnostic accuracy of differentiating degrees of TR. Optimal cutoffs were independently tested in the remaining 40 patients. Results: Measurable regions of signal loss depicting TR jets were noted in 51/61 patients, while 9/10 remaining patients had mild TR by echocardiography. With increasing TR severity, jet area significantly increased (15 +/- 14 to 38 +/- 20 mm(2)), while normalized SI decreased (57 +/- 27 to 23 +/- 11). ROC analysis showed high AUC values in the derivation group and good accuracy in the test group. Conclusion: TR can be quantified from short-axis CMR images in agreement with echocardiography, while circumventing additional image acquisition. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 50 条
  • [1] Comparison of Echocardiographic Assessment of Tricuspid Regurgitation Against Cardiovascular Magnetic Resonance
    Zhan, Yang
    Senapati, Alpana
    Vejpongsa, Pimprapa
    Xu, Jiaqiong
    Shah, Dipan J.
    Nagueh, Sherif F.
    JACC-CARDIOVASCULAR IMAGING, 2020, 13 (07) : 1461 - 1471
  • [2] Tricuspid flow and regurgitation in congenital heart disease and pulmonary hypertension: comparison of 4D flow cardiovascular magnetic resonance and echocardiography
    Driessen, Mieke M. P.
    Schings, Marjolijn A.
    Sieswerda, Gertjan Tj
    Doevendans, Pieter A.
    Hulzebos, Erik H.
    Post, Marco C.
    Snijder, Repke J.
    Westenberg, Jos J. M.
    van Dijk, Arie P. J.
    Meijboom, Folkert J.
    Leiner, Tim
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [3] Prospective Comparison of Valve Regurgitation Quantitation by Cardiac Magnetic Resonance Imaging and Transthoracic Echocardiography
    Cawley, Peter J.
    Hamilton-Craig, Christian
    Owens, David S.
    Krieger, Eric V.
    Strugnell, Wendy E.
    Mitsumori, Lee
    D'Jang, Caryn L.
    Schwaegler, Rebecca G.
    Nguyen, Khanh Q.
    Bianca Nguyen
    Maki, Jeffrey H.
    Otto, Catherine M.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (01) : 48 - 57
  • [4] Indirect quantification of mitral regurgitation using cardiovascular magnetic resonance: A comparison of techniques
    Christian L Polte
    Odd Bech-Hanssen
    Åse A Johnsson
    Sinsia A Gao
    Kerstin M Lagerstrand
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [5] Comparison of Severity of Aortic Regurgitation by Cardiovascular Magnetic Resonance Versus Transthoracic Echocardiography
    Gabriel, Ruvin S.
    Renapurkar, Rahul
    Bolen, Michael A.
    Verhaert, David
    Leiber, Michael
    Flamm, Scott D.
    Griffin, Brian P.
    Desai, Milind Y.
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (07): : 1014 - 1020
  • [6] QUANTIFICATION OF TRICUSPID REGURGITATION - COMPARISON OF DOPPLER ECHOCARDIOGRAPHY AND RADIONUCLIDE VENTRICULOGRAPHY
    GROSSMANN, G
    OTTO, L
    FELDER, C
    CLAUSEN, M
    KRESS, P
    SCHMIDT, A
    HENZE, E
    HOMBACH, V
    ZEITSCHRIFT FUR KARDIOLOGIE, 1992, 81 (01): : 9 - 14
  • [7] Echocardiography Versus Magnetic Resonance Imaging Quantification and Novel Algorithm for Isolated Severe Tricuspid Regurgitation
    Wang, Tom Kai Ming
    Reyaldeen, Reza
    Akyuz, Kevser
    Popovic, Zoran B.
    Gillinov, A. Marc
    Xu, Bo
    Griffin, Brian P.
    Desai, Milind Y.
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 211 : 40 - 48
  • [8] Mitral regurgitation quantification by cardiovascular magnetic resonance: a comparison of indirect quantification methods
    Polte, Christian L.
    Bech-Hanssen, Odd
    Johnsson, Ase A.
    Gao, Sinsia A.
    Lagerstrand, Kerstin M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (06): : 1223 - 1231
  • [9] Mitral regurgitation quantification by cardiovascular magnetic resonance: a comparison of indirect quantification methods
    Christian L. Polte
    Odd Bech-Hanssen
    Åse A. Johnsson
    Sinsia A. Gao
    Kerstin M. Lagerstrand
    The International Journal of Cardiovascular Imaging, 2015, 31 : 1223 - 1231
  • [10] A comparison of the clinical efficacy of echocardiography and magnetic resonance for chronic aortic regurgitation
    Postigo, Andrea
    Perez-David, Esther
    Revilla, Ana
    Abia Raquel, Ladron
    Gonzalez-Mansilla, Ana
    Prieto-Arevalo, Raquel
    Angeles Espinosa, M.
    Ana Lopez-Jimenez, Rosa
    Sevilla, Teresa
    Uruena, Noelia
    Martinez-Legazpi, Pablo
    Oliver, Jose M.
    Fernandez-Aviles, Francisco
    Alberto, San Roman J.
    Bermejo, Javier