Determination of copper in medicinal plants used as dietary supplements by atomic absorption spectrometry with direct flame solid analysis

被引:4
作者
de Moraes Flores, EM [1 ]
Saidelles, APF
de Moraes Flores, EL
Mesko, MF
Pedroso, MP
Dressler, VL
Bittencourt, CF
da Costa, AB
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
[2] Ctr Univ Franciscano, Area Ciencias Saude, BR-97010032 Santa Maria, RS, Brazil
[3] Farmacopeia Brasileira, Agencia Nacl Vigilancia Sanit, BR-70770502 Brasilia, DF, Brazil
[4] Univ Santa Cruz do Sul, Dept Biol, BR-96815900 Santa Cruz Sul, RS, Brazil
关键词
dietary supplements; flame atomic absorption spectrometry; direct solid analysis; copper determination; medicinal plants;
D O I
10.1016/j.microc.2004.02.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An alternative device for the direct solid analysis (DSA) for copper determination by flame atomic absorption spectrometry (FAAS) is proposed. Copper was directly determined in commercial medicinal plants used as dietary supplements. The determination of copper in solid samples by DSA-FAAS was made by using a conventional air-acetylene flame. Between 0.05 and 1.5 mg of each test, sample was weighed directly into a small polyethylene vial connected to the device used for solid introduction into the flame. Test samples were introduced into the flame as a dry aerosol using a T-quartz cell set between the burner and the optical path. The T-quartz cell has a slit in the superior part by which the solid aerosol passes to the flame. A transient signal, evaluated as integrated absorbance, is produced and it is totally integrated in 2 s. Background signals always presented absorbance values less than 0.1. It was found a characteristic mass of 0.8 ng Cu and absolute limit of detection of 1.2 ng (3 s), or 1.2 mug g(-1) if a sample mass of 1 mg was used. Optimized conditions for air flow rate, flame stoichiometry, and so on were established as well. No excessive grinding of the samples was needed and samples with particle of size less than 80 Pm were used throughout. No statistical difference between the results from the proposed system and those obtained by sample digestion and determination by conventional FAAS was observed. With the proposed procedure, more than 50 test samples can be analyzed in 1 h and it can be easily adapted to conventional spectrometers for FAAS. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 21 条
[1]   Quantity estimation of some contaminants in commonly used medicinal plants in the Egyptian market [J].
Abou-Arab, AAK ;
Kawther, MS ;
El Tantawy, ME ;
Badeaa, RI ;
Khayria, N .
FOOD CHEMISTRY, 1999, 67 (04) :357-363
[2]  
Campos R.C., 1990, J. Braz. Chem. Soc, V1, P66, DOI [10.5935/0103-5053.19900014, DOI 10.5935/0103-5053.19900014]
[3]   Improvements in thermospray flame furnace atomic absorption spectrometry [J].
Davies, J ;
Berndt, H .
ANALYTICA CHIMICA ACTA, 2003, 479 (02) :215-223
[4]   Direct cadmium determination in sediment samples by flame atomic absorption spectrometry using multivariate calibration procedures [J].
Flores, EMD ;
Paniz, JNG ;
Saidelles, APF ;
Müller, EI ;
da Costa, AB .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (07) :769-774
[5]  
Flores ÉMD, 2001, SPECTROCHIM ACTA B, V56, P1875
[6]  
Flores TMD, 2002, SPECTROCHIM ACTA B, V57, P2187
[7]   Thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) -: a simple method for trace element determination with microsamples in the μg/1 concentration range [J].
Gáspár, A ;
Berndt, H .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (06) :587-597
[8]   Beam-injection flame-furnace atomic-absorption spectrometry (BIFF-AAS) with low-pressure sample-jet generation [J].
Gáspár, A ;
Berndt, H .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (5-6) :695-699
[9]   Beam injection flame furnace atomic absorption spectrometry:: A new flame method [J].
Gáspár, A ;
Berndt, H .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :240-246
[10]   A brilliant future for microanalysis? [J].
Hinton, RW .
ANALYST, 1997, 122 (11) :1187-1192