Highly wearable cuff-less blood pressure and heart rate monitoring with single-arm electrocardiogram and photoplethysmogram signals

被引:87
|
作者
Zhang, Qingxue [1 ]
Zhou, Dian [1 ,2 ]
Zeng, Xuan [2 ]
机构
[1] Univ Texas Dallas, Dept Elect Engn, 800 W Campbell Rd, Richardson, TX 75080 USA
[2] Fudan Univ, Dept Microelect, 220 Handan Rd, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
Wearable computers; Blood pressure; Heart rate; Photoplethysmogram; Electrocardiography; Pulse transit time; Machine learning; RATE-VARIABILITY; ECG;
D O I
10.1186/s12938-017-0317-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Long-term continuous systolic blood pressure (SBP) and heart rate (HR) monitors are of tremendous value to medical (cardiovascular, circulatory and cerebrovascular management), wellness (emotional and stress tracking) and fitness (performance monitoring) applications, but face several major impediments, such as poor wearability, lack of widely accepted robust SBP models and insufficient proofing of the generalization ability of calibrated models. Methods: This paper proposes a wearable cuff-less electrocardiography (ECG) and photoplethysmogram (PPG)-based SBP and HR monitoring system and many efforts are made focusing on above challenges. Firstly, both ECG/PPG sensors are integrated into a single-arm band to provide a super wearability. A highly convenient but challenging single-lead configuration is proposed for weak single-arm-ECG acquisition, instead of placing the electrodes on the chest, or two wrists. Secondly, to identify heartbeats and estimate HR from the motion artifacts-sensitive weak arm-ECG, a machine learning-enabled framework is applied. Then ECG-PPG heartbeat pairs are determined for pulse transit time (PTT) measurement. Thirdly, a PTT&HR-SBP model is applied for SBP estimation, which is also compared with many PTT-SBP models to demonstrate the necessity to introduce HR information in model establishment. Fourthly, the fitted SBP models are further evaluated on the unseen data to illustrate the generalization ability. A customized hardware prototype was established and a dataset collected from ten volunteers was acquired to evaluate the proof-of-concept system. Results: The semi-customized prototype successfully acquired from the left upper arm the PPG signal, and the weak ECG signal, the amplitude of which is only around 10% of that of the chest-ECG. The HR estimation has a mean absolute error (MAE) and a root mean square error (RMSE) of only 0.21 and 1.20 beats per min, respectively. Through the comparative analysis, the PTT&HR-SBP models significantly outperform the PTT-SBP models. The testing performance is 1.63 +/- 4.44, 3.68, 4.71 mmHg in terms of mean error +/- standard deviation, MAE and RMSE, respectively, indicating a good generalization ability on the unseen fresh data. Conclusions: The proposed proof-of-concept system is highly wearable, and its robustness is thoroughly evaluated on different modeling strategies and also the unseen data, which are expected to contribute to long-term pervasive hypertension, heart health and fitness management.
引用
收藏
页数:20
相关论文
共 26 条
  • [1] Highly wearable cuff-less blood pressure and heart rate monitoring with single-arm electrocardiogram and photoplethysmogram signals
    Qingxue Zhang
    Dian Zhou
    Xuan Zeng
    BioMedical Engineering OnLine, 16
  • [2] Cuff-Less Blood Pressure Monitoring System Using Smartphones
    Tabei, Fatemehsadat
    Gresham, Jon Michael
    Askarian, Behnam
    Jung, Kwanghee
    Chong, Jo Woon
    IEEE ACCESS, 2020, 8 : 11534 - 11545
  • [3] Multimodal Wrist Biosensor for Wearable Cuff-less Blood Pressure Monitoring System
    Rachim, Vega Pradana
    Chung, Wan-Young
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [4] An Armband Wearable Device for Overnight and Cuff-Less Blood Pressure Measurement
    Zheng, Ya-Li
    Yan, Bryan P.
    Zhang, Yuan-Ting
    Poon, Carmen C. Y.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (07) : 2179 - 2186
  • [5] Wearable Cuff-less PTT-based System for Overnight Blood Pressure Monitoring
    Zheng, Yali
    Yan, Bryan P.
    Zhang, Yuanting
    Yu, C. M.
    Poon, Carmen C. Y.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 6103 - 6106
  • [6] Cuff-less blood pressure estimation from photoplethysmography signal and electrocardiogram
    Yao, Li-Ping
    Pan, Zhong-liang
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (02) : 397 - 408
  • [7] Cuff-less blood pressure estimation from photoplethysmography signal and electrocardiogram
    Li-Ping Yao
    Zhong-liang Pan
    Physical and Engineering Sciences in Medicine, 2021, 44 : 397 - 408
  • [8] Posture-Dependent Variability in Wrist Ballistocardiogram-Photoplethysmogram Pulse Transit Time: Implication to Cuff-Less Blood Pressure Tracking
    Shin, Sungtae
    Mousavi, Azin
    Lyle, Sophia
    Jang, Elisabeth
    Yousefian, Peyman
    Mukkamala, Ramakrishna
    Jang, Dae-Geun
    Kwon, Ui Kun
    Kim, Youn Ho
    Hahn, Jin-Oh
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (01) : 347 - 355
  • [9] Design and Development of Continuous Cuff-less Blood Pressure Monitoring Devices
    Griggs, Devon
    Sharma, Manuja
    Naghibi, Arian
    Wallin, Colton
    Ho, Victor
    Barbosa, Karinne
    Ghirmai, Tadesse
    Cao, Hung
    Krishnan, Sandeep K.
    2016 IEEE SENSORS, 2016,
  • [10] Cuff-Less Continuous Blood Pressure Monitoring System Using Pulse Transit Time Techniques
    Zaki, Wan Suhaimizan Wan
    Correia, Ricardo
    Korposh, Serhiy
    Hayes-Gill, Barrie R.
    Morgan, Stephen P.
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2016, 8 (01): : 51 - 57