The effect of laryngoscope types on hemodynamic response and optic nerve sheath diameter McCoy, Macintosh, and C-MAC video-laryngoscope

被引:5
作者
Kucukosman, Gamze [1 ]
Aydin, Bengu G. [1 ]
Gulcek, Necla [1 ]
Okyay, Rahsan D. [1 ]
Piskin, Ozcan [1 ]
Ayoglu, Hilal [1 ]
机构
[1] Zonguldak Bulent Ecevit Univ, Dept Anesthesiol & Reanimat, Zonguldak, Turkey
关键词
hemodynamic response; laryngoscope types; optic nerve sheath diameter; ELEVATED INTRACRANIAL-PRESSURE; ENDOTRACHEAL INTUBATION; TRACHEAL INTUBATION; VIDEOLARYNGOSCOPY; SURGERY;
D O I
10.15537/smj.2020.9.25349
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: This study aims to investigate the effect of McCoy, Macintosh laryngoscope, and C-MAC video-laryngoscopes on optic nerve sheath diameter (ONSD) and hemodynamic responses to laryngoscopy and intubation. Methods: This prospective randomized study was conducted in Zonguldak Bulent Ecevit University Hospital, Zonguldak, Turkey, between July 2019 and January 2020. Informed written consent was obtained from all patients. Patients with previous intracranial/ocular surgery or glaucoma were excluded from the study. The patients were randomized to use McCoy, Macintosh, and C-MAC (30 per group). Intubations were performed by the same person. Mean arterial pressure, heart rate (HR), and ONSD were recorded before the induction and repeated in 1, 3, 5, and 10 minutes after the intubation. Results: The effects of laryngoscopy and intubation on hemodynamic responses and ONSD were similar between groups (p>0.05). While the comparison within groups showed ONSD increase in McCoy group and HR and ONSD increase in the Macintosh group compared to baseline 1 min after the intubation, no change was observed in hemodynamic responses and ONSD measurements in the C-MAC (R) group (p>0.05). Conclusions: In this study, there was no significant difference between the groups in terms of ONSD and hemodynamic responses to laryngoscopy and intubation. It was observed that there were no significant changes in ONSD values just in C-MAC (R) video-laryngoscope group. Therefore, intubations with C-MAC (R) video-laryngoscope are thought to be more appropriate for patients with an increase in intracranial pressure.
引用
收藏
页码:930 / 937
页数:8
相关论文
共 37 条
  • [1] Comparison of cardiac output and hemodynamic responses of intubation among different videolaryngoscopies in normotensive and hypertensive patients
    Abdelgawad, Amro Faez
    Shi, Qin-fang
    Halawa, Mohamed Abo
    Wu, Zhi-lin
    Wu, Zhou-yang
    Chen, Xiang-dong
    Yao, Shang-long
    [J]. JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2015, 35 (03) : 432 - 438
  • [2] Aggarwal Hiteshi, 2019, Anesth Essays Res, V13, P308, DOI 10.4103/aer.AER_7_19
  • [3] Comparative Effectiveness of the C-MAC Video Laryngoscope versus Direct Laryngoscopy in the Setting of the Predicted Difficult Airway
    Aziz, Michael F.
    Dillman, Dawn
    Fu, Rongwei
    Brambrink, Ansgar M.
    [J]. ANESTHESIOLOGY, 2012, 116 (03) : 629 - 636
  • [4] Ballantyne S A, 2002, Eur J Ultrasound, V15, P145, DOI 10.1016/S0929-8266(02)00036-8
  • [5] Buhari Faiza Sulaiman, 2016, J Anaesthesiol Clin Pharmacol, V32, P505, DOI 10.4103/0970-9185.194766
  • [6] Butterworth I.V.J.F., 2013, MORGAN MIKHAILS CLIN, V5th ed., P575
  • [7] Butterworth JF., 2013, Morgan and Mikhail's Clinical Anesthesiology, V5th, P309
  • [8] A randomised, controlled crossover comparison of the C-MAC videolaryngoscope with direct laryngoscopy in 150 patients during routine induction of anaesthesia
    Cavus, Erol
    Thee, Carsten
    Moeller, Thora
    Kieckhaefer, Joerg
    Doerges, Volker
    Wagner, Klaus
    [J]. BMC ANESTHESIOLOGY, 2011, 11
  • [9] The C-MAC Videolaryngoscope: First Experiences with a New Device for Videolaryngoscopy-Guided Intubation
    Cavus, Erol
    Kieckhaefer, Joerg
    Doerges, Volker
    Moeller, Thora
    Thee, Carsten
    Wagner, Klaus
    [J]. ANESTHESIA AND ANALGESIA, 2010, 110 (02) : 473 - 477
  • [10] Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis
    Dubourg, Julie
    Javouhey, Etienne
    Geeraerts, Thomas
    Messerer, Mahmoud
    Kassai, Behrouz