A tris (2,2′-bipyridyl)cobalt(III)-bovine serum albumin composite membrane for biosensors

被引:43
作者
Zhuo, Ying [1 ]
Yuan, Ruo [1 ]
Chai, Yaqin [1 ]
Sun, Aili [1 ]
Zhang, Ying [1 ]
Yang, Jiuzhi [1 ]
机构
[1] SW Univ, Coll Chem & Chem Engn, Key Lab Analyt Chem Chongqing, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
amperometric enzyme immunosensor; bovine serum albumin (BSA); Co(bpy)(3+)(3); horseradish peroxidase (HRP); carcinoembryonic antigen (CEA);
D O I
10.1016/j.biomaterials.2006.06.012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A concept based on a novel redox-biocompatible composite protein membrane fabrication, double enzyme membrane modification technique and antibody immobilization, was exploited to develop a highly sensitive amperometric enzyme immunosensor for detection of carcinoembryonic antigen (CEA). In this concept, a solution of bovine serum albumin (BSA) containing horseradish peroxidase (HRP) is coated on the gold electrode in such a way that the first enzyme membrane is achieved. Then tris(2,2'-bipyridyl) cobalt(III) (Co(bpy)(3)(3+)), as a mediator, was embedded in BSA-HRP composite membrane vis the electrostatic force and hydrophobe functions. Later a self-assembled conductive nano-Au monolayer was constructed onto the resultant electrode surface by electrostatic interaction between the negatively charged nano-Au and positively charged Co(bpy)(3)(3+). Protein A is used as a binding material to achieve an adjusted (but not 3 random) orientation of the antibodies surface for efficient combination of antigens. Finally, the HRP, was employed to block the possible remaining active sites and avoid the non-specific adsorption, which acts not only as a blocking reagent instead of the commonly used BSA but also as the conventional enzyme-labeling to amplify the response of the antigen-antibody reaction. The immunosensor constructed with the double layer biocatalytic HRP membranes and the desirable Co(bpy)(3)(3+)/BSA redox-biocompatible composite membrane performed high sensitivity and a wide linear response to CEA in the range of 0.50-80.00 ng/mL with a limit of detection of 0.14ng/mL, as well as good stability and long-term life. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5420 / 5429
页数:10
相关论文
共 48 条
[41]  
WU J, 2006, IN PRESS BIOSENS BIO
[42]   Microfluidic enzyme immunosensors with immobilised protein A and G using chemiluminescence detection [J].
Yakovleva, J ;
Davidsson, R ;
Bengtsson, M ;
Laurell, T ;
Emnéus, J .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (01) :21-34
[43]   ASSAY OF PLASMA INSULIN IN HUMAN SUBJECTS BY IMMUNOLOGICAL METHODS [J].
YALOW, RS ;
BERSON, SA .
NATURE, 1959, 184 (4699) :1648-1649
[44]   A new antibody immobilization strategy based on electrodeposition of nanometer-sized hydroxyapatite for label-free capacitive immunosensor [J].
Yang, L ;
Wei, WZ ;
Gao, XH ;
Xia, JJ ;
Tao, H .
TALANTA, 2005, 68 (01) :40-46
[45]  
YIN TJ, 2005, IN PRESS SENSOR 1227
[46]   Electrochemical biosensing based on universal affinity biocomposite platforms [J].
Zacco, E ;
Pividori, MI ;
Alegret, S .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (07) :1291-1301
[47]  
ZHU Q, 2006, ELECTROCHIM ACTA, V51, P3763
[48]   An amperometric immunosensor based on immobilization of hepatitis B surface antibody on gold electrode modified gold nanoparticles and horseradish peroxidase [J].
Zhuo, Y ;
Yuan, R ;
Chai, YQ ;
Zhang, Y ;
Li, XL ;
Zhu, Q ;
Wang, N .
ANALYTICA CHIMICA ACTA, 2005, 548 (1-2) :205-210