Fully Automatic Sample Treatment by Integration of Microextraction by Packed Sorbents into Commercial Capillary Electrophoresis-Mass Spectrometry Equipment: Application to the Determination of Fluoroquinolones in Urine

被引:40
作者
Morales-Cid, Gabriel [1 ]
Cardenas, Soledad [1 ]
Simonet, Bartolome M. [1 ]
Valcarcel, Miguel [1 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14071 Cordoba, Spain
关键词
SOLID-PHASE EXTRACTION; QUINOLONE RESIDUES; IN-LINE; CE-MS; CHROMATOGRAPHY; MECHANISM; ANTIBIOTICS; SENSITIVITY; SEPARATION; FISH;
D O I
10.1021/ac900234j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a new and innovative way to integrate microextraction by packed sorbents (MEPS) into commercial CE equipment. The suggested integration allows the automatic sample cleanup and preconcentration requiring only a few microliters of sample and no additional hardware and software. The MEPS was integrated in the outlet region of a commercial CE equipment cartridge in order to provide easy manipulation and exchange. The robustness of the proposed integration was demonstrated by the design and use of a (MEPS)-nonaqueous capillary electrophoresis (NACE)-MS method used to determine fluoroquinolones "FQs" (namely, ofloxacin, marbofloxacin, enrofloxacin, danofloxacin, and difloxacin) in urine. The method allows the analysis of micrograms per liter of FQs to be carried out with only 48 mu L of urine sample. The obtained LODs were in the range 6.3-10.6 mu g/L. An analysis of spiked urine samples was used to validate the method. Absolute recoveries were in the range of 71-109% while the precision expressed as repetitivity of peak area was lower than 5.9%.
引用
收藏
页码:3188 / 3193
页数:6
相关论文
共 28 条
[1]   Analytical strategies to determine quinolone residues in food and the environment [J].
Andreu, Vicente ;
Blasco, Cristina ;
Pico, Yolanda .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (06) :534-556
[2]   The quinolones: Past, present, and future [J].
Andriole, VT .
CLINICAL INFECTIOUS DISEASES, 2005, 41 :S113-S119
[3]   Lowering the concentration limits of detection by on-line solid-phase extraction-capillary electrophoresis-electrospray mass spectrometry [J].
Benavente, Fernando ;
Cristina Vescina, M. ;
Hernandez, Elena ;
Sanz-Nebot, Victoria ;
Barbosa, Jose ;
Guzman, Norberto A. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1140 (1-2) :205-212
[4]   Analysis of fluoroquinolones in biological fluids by high-performance liquid chromatography [J].
Carlucci, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) :343-367
[5]   Mechanism of fluoroquinolone action [J].
Drlica, K .
CURRENT OPINION IN MICROBIOLOGY, 1999, 2 (05) :504-508
[6]   Quantitative analysis of methadone in human urine samples by microextraction in packed syringe-gas chromatography-mass spectrometry (MEPS-GC-MS) [J].
El-Beqqali, Aziza ;
Abdel-Rehim, Mohamed .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (15) :2501-2505
[7]  
Hernández M, 2002, ELECTROPHORESIS, V23, P506, DOI 10.1002/1522-2683(200202)23:3<506::AID-ELPS506>3.0.CO
[8]  
2-C
[9]   Simultaneous determination of different classes of antibiotics in fish and livestock by CE-MS [J].
Juan-Garcia, Ana ;
Font, Guillermina ;
Pico, Yolanda .
ELECTROPHORESIS, 2007, 28 (22) :4180-4191
[10]   Determination of quinolone residues in chicken and fish by capillary electrophoresis-mass spectrometry [J].
Juan-Garcia, Ana ;
Font, Guillermina ;
Pico, Yolanda .
ELECTROPHORESIS, 2006, 27 (11) :2240-2249