Microchannel plate operation at high count rates: New results

被引:43
作者
Tremsin, AS
Pearson, JF
Fraser, GW
Feller, WB
White, P
机构
[1] UNIV LEICESTER,DEPT PHYS & ASTRON,XRAY ASTRON GRP,LEICESTER LE1 7RH,LEICS,ENGLAND
[2] NOVA SCI INC,STURBRIDGE,MA 01566
基金
美国国家科学基金会;
关键词
D O I
10.1016/0168-9002(96)00482-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe an experimental study of two distinct microchannel plate (MCP) detector configurations with extended dynamic range. First, we report on measurements made with single MCPs of very low resistance (less than or equal to 500 k Omega) bonded to a Peltier cooler. Stable, reproducible operation for a rear-cooled MCP with 10 mu m diameter channels of length-to-diameter ratio 60:1 was achieved for biases up to 1320 V. At this point, the MCP strip current was 5.1 mA and the rate of internal heat generation, 0.78 Wcm(-2) A maximum count rate of 10(8) cm(-2)s(-1), limited by the available intensity of UV illumination, was observed, coupled to a dark noise count rate of less than 1 cm(-2)s(-1). Second, we describe a substantial (up to 20-fold) improvement in count rate capability for two-stage MCP multipliers incorporating plates with gold, rather than nichrome, electrodes. We also present, in support of the experimental study, a thermal model of bonded, conductively-cooled MCPs which we use to determine critical parameters for stable detector operation.
引用
收藏
页码:139 / 151
页数:13
相关论文
共 50 条
  • [21] High detection efficiency neutron sensitive microchannel plate
    Pan, J.
    Yang, Y.
    Tian, Y.
    Zeng, M.
    Deng, T.
    Xu, W.
    Han, X.
    Sun, S.
    Lv, J.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [22] The investigation of the operation of the device with a microchannel plate as an ion receiver for the dust particles' registration
    Voronov K.E.
    Piyakov I.V.
    Ryazanov D.M.
    Telegin A.M.
    Applied Physics, 2023, (06): : 84 - 90
  • [23] OPERATION OF A SPARK CHAMBER AT A HIGH COUNT RATE
    USOV, YP
    ANANIN, PS
    STERLIGOV, AG
    TOLMACHEVA, VG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1970, (04): : 1003 - +
  • [24] Effect of microchannel plate design on fluid flow uniformity at low flow rates
    Griffini, Gian Marco
    Gavriilidis, Asterios
    CHEMICAL ENGINEERING & TECHNOLOGY, 2007, 30 (03) : 395 - 406
  • [25] THE UV PERFORMANCE OF AN OPEN FACED MICROCHANNEL PLATE INTENSIFIER - INITIAL RESULTS
    READ, PD
    CARTER, MK
    PATCHETT, BE
    VANBREDA, IG
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1992, (121): : 57 - 64
  • [26] TECHNIQUE AND RESULTS OF A NEW OPERATION TO STRENGTHEN THE SCLERA IN HIGH MYOPIA
    AWETISSOW, ES
    TARUTTA, HP
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1987, 191 (01) : 22 - 25
  • [27] EFFECT OF PIPETTE TYPE AND SAMPLE SIZE ON PLATE COUNT RESULTS
    MARTH, EH
    PROCTOR, JF
    HUSSONG, RV
    JOURNAL OF MILK AND FOOD TECHNOLOGY, 1965, 28 (10): : 314 - &
  • [28] Performance studies of microchannel plate PMTs in high magnetic fields
    Lehmann, A.
    Britting, A.
    Eyrich, W.
    Pizzolotto, C.
    Teufel, A.
    Dueren, M.
    Foehl, K.
    Hoek, M.
    Lu, S.
    Schepers, G.
    Seitz, B.
    Sfienti, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 595 (01) : 173 - 176
  • [29] High speed imager AXAF calibration microchannel plate detector
    Evans, IN
    Kellogg, EM
    McDermott, WC
    Ordway, MP
    Rosenberg, JM
    Wargelin, BJ
    GRAZING INCIDENCE AND MULTILAYER X-RAY OPTICAL SYSTEMS, 1997, 3113 : 18 - 29
  • [30] Microchannel plate for high-efficiency field emission display
    Yi, W
    Jin, S
    Jeong, T
    Lee, J
    Yu, S
    Choi, Y
    Kim, JM
    APPLIED PHYSICS LETTERS, 2000, 77 (11) : 1716 - 1718