Acoustic emission monitoring for assessment of prestressed concrete beams

被引:82
作者
ElBatanouny, Mohamed K. [1 ]
Ziehl, Paul H. [1 ]
Larosche, Aaron [1 ]
Mangual, Jese [1 ]
Matta, Fabio [1 ]
Nanni, Antonio [2 ]
机构
[1] Univ S Carolina, Dept Civil & Environm Engn, Columbia, SC 29208 USA
[2] Univ Miami, Dept Civil Arch & Environ Engn, Coral Gables, FL 33146 USA
关键词
Acoustic emission; Non-destructive testing; Prestressed concrete; Corrosion; Cyclic load test (CLT); IN-SITU EVALUATION; B-VALUE; SLAB SYSTEMS;
D O I
10.1016/j.conbuildmat.2014.01.100
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Acoustic emission (AE) was used to monitor eight prestressed concrete (PC) T-shaped beams that were tested per the ACI 437 cyclic load test (CLT) method. Limited research has examined the validity of this test method for PC structures. The study aims to explore the use of AE for damage evaluation as a supplement to conventional measurements used to assess the condition of a structure based on the CLT acceptance criteria. The beams had different initial conditions: five specimens were pre-cracked and corroded to different corrosion levels while the remaining unconditioned beams served as control specimens. AE enabled to monitor the accumulation of damage during the load tests and damage quantification charts based on AE data are presented. These charts allowed determining load test failure with better sensitivity than the existing ACI 437 evaluation criteria. The charts enabled the assessment of damage regardless of the specimens' initial condition. In addition, it is shown that accurate damage source location and crack mapping can be achieved by using suitably filtered AE data. Published by Elsevier Ltd.
引用
收藏
页码:46 / 53
页数:8
相关论文
共 50 条
  • [31] Numerical Assessment on Bonded and Unbonded Prestressed Concrete Beams
    Pang, Miao
    Liu, Xing
    Dong, Yi
    Lou, Tiejiong
    BUILDINGS, 2022, 12 (10)
  • [32] Monitoring the flexural performance ofGFRPrepaired corroded reinforced concrete beams using passive acoustic emission technique
    Garhwal, Sunil
    Sharma, Shruti
    Sharma, Sandeep Kumar
    STRUCTURAL CONCRETE, 2021, 22 (01) : 198 - 214
  • [33] Structural performance assessment of deteriorated prestressed concrete beams
    Kim, Tae-Hoon
    Banga, Choon-Seok
    Yeob, In-Ho
    Sunc, Chang-Ho
    Kimd, Ick-Hyun
    COMPUTERS AND CONCRETE, 2025, 35 (04) : 473 - 481
  • [34] Vibration monitoring and acoustic emission sensing during progressive load tests of corroded reinforced concrete beams
    van de Velde, Menno
    Vandecruys, Eline
    Verstrynge, Els
    Reynders, Edwin
    Lombaert, Geert
    ENGINEERING STRUCTURES, 2024, 306
  • [35] Intensity Analysis Method of Acoustic Emission Signals for the Damage Monitoring of Post-Tensioned Concrete Beams
    Bruno, Ezio
    Scionti, Giuseppe
    Calabrese, Luigi
    Proverbio, Edoardo
    MATERIALS, 2024, 17 (16)
  • [36] Non-Destructive Evaluation for Corrosion Monitoring in Concrete: A Review and Capability of Acoustic Emission Technique
    Zaki, Ahmad
    Chai, Hwa Kian
    Aggelis, Dimitrios G.
    Alver, Ninel
    SENSORS, 2015, 15 (08) : 19069 - 19101
  • [37] Analytical Performance Assessment of Deteriorated Prestressed Concrete Beams
    Tae-Hoon Kim
    International Journal of Concrete Structures and Materials, 17
  • [38] Acoustic Emission Monitoring in Prestressed Concrete: A Comparative Study of Signal Attenuation from Wire Breaks and Rebound Hammer Impulses
    Kaeding, Max
    Marx, Steffen
    APPLIED SCIENCES-BASEL, 2024, 14 (07):
  • [39] A Global Integrity Parameter with Acoustic Emission for Load Testing of Prestressed Concrete Girders
    Barrios, Francisco A.
    Ziehl, Paul H.
    ACI STRUCTURAL JOURNAL, 2015, 112 (01) : 3 - 11
  • [40] Fresh Concrete Curing Monitoring Using Acoustic Emission
    Dias, Ashwin P. S.
    Lefever, Gerlinde
    Aggelis, Dimitrios G.
    PROCEEDINGS OF THE 75TH RILEM ANNUAL WEEK 2021, 2023, 40 : 831 - 837