Simulation and experimental verification of a fuel calibration system based on metering cylinder

被引:7
|
作者
Wang, Bin [1 ]
Jin, Xin [1 ]
Huang, Ruo [1 ]
Chen, Shilong [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Jiangsu Prov Key Lab Aerosp Power Syst, Nanjing 210016, Jiangsu, Peoples R China
关键词
Turbine flowmeter; Calibration; Metering cylinder; Meter coefficient;
D O I
10.1016/j.flowmeasinst.2014.05.020
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Simulation and experimental verification of a fuel calibration system based on hydraulic metering cylinder has been carried out in this paper. A novel hydraulic metering cylinder is designed for more accurate flow rate measurement. The calibration workbench with this cylinder is presented and mathematically modeled. Also, the calibration system is numerically simulated in AMESim. The simulation results show that the calibration system can work smoothly. In addition, the impact of given plunger speeds and calibration strokes on the accuracy of the calibration results is experimentally verified. It can be found that stroke of approximate 600 mm and a medium given speed are the most effective ways to reduce the measuring error under the experimental condition provided in this paper. Moreover, a calibration error less than 0.5% is achieved in the fuel calibration system. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 50 条
  • [41] Experimental Microwave Imaging System Calibration via Cycle-GAN
    Martin, Ben
    Edwards, Keeley
    Jeffrey, Ian
    Gilmore, Colin
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2023, 71 (09) : 7491 - 7503
  • [42] Improved Calibration for an Experimental Time-Domain Microwave Imaging System
    Santorelli, Adam
    Kirshin, Evgeny
    Porter, Emily
    Popovic, Milica
    Schwartz, Joshua
    2013 7TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2013, : 801 - 805
  • [43] Optical transmission trajectories in single tapered fibers of TOFA by numerical simulation and experimental verification
    Jiang, Dongyu
    Jiao, Peng
    Li, Fengyan
    Xing, Yuwen
    Du, Yajie
    Fu, Yang
    Wang, Yun
    Huang, Yonggang
    OPTICAL FIBER TECHNOLOGY, 2024, 87
  • [44] Experimental Investigation of Calibration and Resolution in Human-Automation System Interaction
    Maehigashi, Akihiro
    Miwa, Kazuhisa
    Terai, Hitoshi
    Kojima, Kazuaki
    Morita, Junya
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2013, E96A (07) : 1625 - 1636
  • [45] The laser-based calibration system of delta spectrometer
    Malakhov, A. I.
    Anisimov, Yu. S.
    Gmuca, S.
    Kizka, V. A.
    Kliman, J.
    Krasnov, V. A.
    Kurepin, A. B.
    Kuznetsov, S. N.
    Livanov, A. N.
    Matousek, V.
    Morhac, M.
    Turzo, I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 566 (02) : 413 - 421
  • [46] Calibration of the Structured Light System Based on Active Projection
    Sun Yong
    Li Yuan
    Wang Qinglin
    Chen Hui
    2011 30TH CHINESE CONTROL CONFERENCE (CCC), 2011, : 4492 - 4497
  • [47] A calibration tool for a CCD camera based vision system
    Xu, G
    Tan, SL
    Low, SP
    Heng, YS
    Lai, WC
    Du, XH
    OPTICAL METROLOGY ROADMAP FOR THE SEMICONDUCTOR, OPTICAL, AND DATA STORAGE INDUSTRIES, 2000, 4099 : 154 - 165
  • [48] Dual manipulator system calibration based on virtual constraints
    Zhu, Q.
    Xie, X.
    Li, C.
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2019, 67 (06) : 1149 - 1159
  • [49] A simple laboratory-based radon calibration system
    Xu, Bo-chao
    Burnett, W. C.
    Lane-Smith, Derek
    Yu, Zhi-gang
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 283 (02) : 457 - 463
  • [50] Airborne radar calibration system based on the overlap strip
    Wang, Z. (gswzh870115@163.com), 1600, Science Press (41):