Simulation and experimental verification of a fuel calibration system based on metering cylinder

被引:7
|
作者
Wang, Bin [1 ]
Jin, Xin [1 ]
Huang, Ruo [1 ]
Chen, Shilong [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Jiangsu Prov Key Lab Aerosp Power Syst, Nanjing 210016, Jiangsu, Peoples R China
关键词
Turbine flowmeter; Calibration; Metering cylinder; Meter coefficient;
D O I
10.1016/j.flowmeasinst.2014.05.020
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Simulation and experimental verification of a fuel calibration system based on hydraulic metering cylinder has been carried out in this paper. A novel hydraulic metering cylinder is designed for more accurate flow rate measurement. The calibration workbench with this cylinder is presented and mathematically modeled. Also, the calibration system is numerically simulated in AMESim. The simulation results show that the calibration system can work smoothly. In addition, the impact of given plunger speeds and calibration strokes on the accuracy of the calibration results is experimentally verified. It can be found that stroke of approximate 600 mm and a medium given speed are the most effective ways to reduce the measuring error under the experimental condition provided in this paper. Moreover, a calibration error less than 0.5% is achieved in the fuel calibration system. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 50 条
  • [1] A hardware-software system for the automation of verification and calibration of oil metering units secondary equipment
    Boyarnikov, A. V.
    Boyarnikova, L. V.
    Kozhushko, A. A.
    Sekachev, A. F.
    OIL AND GAS ENGINEERING (OGE-2017), 2017, 1876
  • [2] Calibration of simulation parameters of flaxed seeds using discrete element method and verification of seed-metering test
    Shi L.
    Ma Z.
    Zhao W.
    Yang X.
    Sun B.
    Zhang J.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2019, 35 (20): : 25 - 33
  • [3] Calibration of Simulation Parameters of Mung Bean Seeds Using Discrete Element Method and Verification of Seed-metering Test
    Zhang S.
    Zhang R.
    Chen T.
    Fu J.
    Yuan H.
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2022, 53 (03): : 71 - 79
  • [4] Research of Digital Metering System and Calibration Technology of Smart Substation
    Zhou, Feng
    Cheng, Yingying
    Xiao, Ji
    Du, Jie
    PROCEEDINGS OF 2014 IEEE WORKSHOP ON ADVANCED RESEARCH AND TECHNOLOGY IN INDUSTRY APPLICATIONS (WARTIA), 2014, : 1240 - 1242
  • [5] A Calibration Method for Power Metering System with Electronic Instrument Transformers
    Wang, Peng
    Tan, Dandan
    2012 3RD IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT EUROPE), 2012,
  • [6] Electromagnetic Modeling and Simulation: Challenges in Validation, Verification, and Calibration
    Sevgi, Levent
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2014, 56 (04) : 750 - 758
  • [7] Verification of In place Calibration for Time-domain Microwave Imaging Development of Time-domain Microwave Breast Imaging System for Experimental Verification of In place Calibration
    Kwon, Sollip
    Son, Seong-Ho
    Lee, Kwang-Jae
    Lee, Seungjun
    2016 URSI ASIA-PACIFIC RADIO SCIENCE CONFERENCE (URSI AP-RASC), 2016, : 688 - 690
  • [8] Verification of a calibration system for power quality instruments
    Svensson, S
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (05) : 1391 - 1394
  • [9] Computer-Based Simulation and Test System for the Calibration of EFI Engine
    赵长禄
    张付军
    黄英
    葛蕴珊
    刘福水
    Journal of Beijing Institute of Technology, 2004, (01) : 71 - 75
  • [10] A Calibration Method of Ship Borne Theodolite Based on Stellar Simulation System
    Wang Qianxue
    Liu Xinming
    Feng Xiaoyong
    Zhou Haiyuan
    LASER & OPTOELECTRONICS PROGRESS, 2018, 55 (02)