Budget Impact Analysis of Switching to Digital Mammography in a Population-Based Breast Cancer Screening Program: A Discrete Event Simulation Model

被引:20
|
作者
Comas, Merce [1 ,2 ,3 ]
Arrospide, Arantzazu [3 ,4 ]
Mar, Javier [3 ,4 ]
Sala, Maria [1 ,2 ,3 ]
Vilaprinyo, Ester [3 ,5 ]
Hernandez, Cristina [1 ,2 ]
Cots, Francesc [2 ,3 ,6 ]
Martinez, Juan [7 ]
Castells, Xavier [1 ,2 ,3 ]
机构
[1] Hosp del Mar, Epidemiol & Evaluat Dept, Barcelona, Spain
[2] Hosp del Mar Med Res Inst IMIM, Barcelona, Spain
[3] Red Invest Serv Salud Enfermedades Cron REDISSEC, Valencia, Spain
[4] Hosp Alto Deba, Gipuzkoa Oeste Res Unit, Arrasate Mondragon, Spain
[5] Univ Lleida, Biomed Res Inst Lleida IRBLLEIDA, Basic Med Sci Dept, Lleida, Spain
[6] Hosp del Mar, Management Control Dept, Barcelona, Spain
[7] Hosp del Mar, Dept Radiol, Barcelona, Spain
来源
PLOS ONE | 2014年 / 9卷 / 05期
关键词
FILM MAMMOGRAPHY; COST-EFFECTIVENESS; IMPLEMENTATION; TRANSITION; REDUCTION; INTERVAL;
D O I
10.1371/journal.pone.0097459
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: To assess the budgetary impact of switching from screen-film mammography to full-field digital mammography in a population-based breast cancer screening program. Methods: A discrete-event simulation model was built to reproduce the breast cancer screening process (biennial mammographic screening of women aged 50 to 69 years) combined with the natural history of breast cancer. The simulation started with 100,000 women and, during a 20-year simulation horizon, new women were dynamically entered according to the aging of the Spanish population. Data on screening were obtained from Spanish breast cancer screening programs. Data on the natural history of breast cancer were based on US data adapted to our population. A budget impact analysis comparing digital with screen-film screening mammography was performed in a sample of 2,000 simulation runs. A sensitivity analysis was performed for crucial screening-related parameters. Distinct scenarios for recall and detection rates were compared. Results: Statistically significant savings were found for overall costs, treatment costs and the costs of additional tests in the long term. The overall cost saving was 1,115,857(sic) (95%CI from 932,147 to 1,299,567) in the 10th year and 2,866,124(sic) (95% CI from 2,492,610 to 3,239,638) in the 20th year, representing 4.5% and 8.1% of the overall cost associated with screen-film mammography. The sensitivity analysis showed net savings in the long term. Conclusions: Switching to digital mammography in a population-based breast cancer screening program saves long-term budget expense, in addition to providing technical advantages. Our results were consistent across distinct scenarios representing the different results obtained in European breast cancer screening programs.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Breast Cancer Screening Results 5 Years after Introduction of Digital Mammography in a Population-based Screening Program
    Karssemeijer, Nico
    Bluekens, Adriana M.
    Beijerinck, David
    Deurenberg, Jan J.
    Beekman, Matthijs
    Visser, Roelant
    van Engen, Ruben
    Bartels-Kortland, Annemieke
    Broeders, Mireille J.
    RADIOLOGY, 2009, 253 (02) : 353 - 358
  • [2] Implementation of Digital Mammography in a Population-based Breast Cancer Screening Program: Effect of Screening Round on Recall Rate and Cancer Detection
    Sala, Maria
    Comas, Merce
    Macia, Francesc
    Martinez, Juan
    Casamitjana, Montserrat
    Castells, Xavier
    RADIOLOGY, 2009, 252 (01) : 31 - 39
  • [3] Cost-effectiveness and budget impact analysis of a population-based screening program for colorectal cancer
    Pil, L.
    Fobelets, M.
    Putman, K.
    Trybou, J.
    Annemans, L.
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2016, 32 : 72 - 78
  • [4] Comparison of Digital Mammography Alone and Digital Mammography Plus Tomosynthesis in a Population-based Screening Program
    Skaane, Per
    Bandos, Andriy I.
    Gullien, Randi
    Eben, Ellen B.
    Ekseth, Ulrika
    Haakenaasen, Unni
    Izadi, Mina
    Jebsen, Ingvild N.
    Jahr, Gunnar
    Krager, Mona
    Niklason, Loren T.
    Hofvind, Solveig
    Gur, David
    RADIOLOGY, 2013, 267 (01) : 47 - 56
  • [5] Digital Breast Tomosynthesis and Synthetic 2D Mammography versus Digital Mammography: Evaluation in a Population-based Screening Program
    Hofvind, Solveig
    Hovda, Tone
    Holen, Asne S.
    Lee, Christoph I.
    Albertsen, Judy
    Bjorndal, Hilde
    Brandal, Siri H. B.
    Gullien, Randi
    Lomo, Jon
    Park, Daehoon
    Romundstad, Linda
    Suhrke, Pal
    Vigeland, Einar
    Skaane, Per
    RADIOLOGY, 2018, 287 (03) : 787 - 794
  • [6] Impact of transition from analog screening mammography to digital screening mammography on screening outcome in The Netherlands: a population-based study
    Nederend, J.
    Duijm, L. E. M.
    Louwman, M. W. J.
    Groenewoud, J. H.
    Donkers-van Rossum, A. B.
    Voogd, A. C.
    ANNALS OF ONCOLOGY, 2012, 23 (12) : 3098 - 3103
  • [7] Digital Mammography versus Breast Tomosynthesis: Impact of Breast Density on Diagnostic Performance in Population-based Screening
    Osteras, Bjorn Helge
    Martinsen, Anne Catrine T.
    Gullien, Randi
    Skaane, Per
    RADIOLOGY, 2019, 293 (01) : 60 - 68
  • [8] Impact of switching from digital mammography to tomosynthesis plus digital mammography on breast cancer screening in Alberta, Canada
    Pang, Jack X. Q.
    Newsome, James
    Sun, Maggie
    Chiang, Bonnie
    Mutti-Packer, Seema
    McDonald, Sheila W.
    Yang, Huiming
    JOURNAL OF MEDICAL SCREENING, 2022, 29 (01) : 38 - 43
  • [9] First Epidemiological Analysis of Breast Cancer Incidence and Tumor Characteristics after Implementation of Population-Based Digital Mammography Screening
    Weigel, S.
    Batzler, W. U.
    Decker, T.
    Hense, H. W.
    Heindel, W.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (12): : 1144 - 1150
  • [10] Consequences of digital mammography in population-based breast cancer screening: initial changes and long-term impact on referral rates
    Bluekens, Adriana M. J.
    Karssemeijer, Nico
    Beijerinck, David
    Deurenberg, Jan J. M.
    van Engen, Ruben E.
    Broeders, Mireille J. M.
    den Heeten, Gerard J.
    EUROPEAN RADIOLOGY, 2010, 20 (09) : 2067 - 2073