Dose verification for liver target volumes undergoing respiratory motion

被引:1
|
作者
Dyce, Emma [1 ]
Cutajar, Dean [2 ]
Metcalfe, Peter [2 ]
Downes, Simon [1 ]
机构
[1] Prince Wales Hosp, Nelune Comprehens Canc Ctr, Sydney, NSW, Australia
[2] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
关键词
Liver; 4D; IGRT; Respiratory motion; IMRT; OPTIMIZATION; DELIVERY; IMPACT; SBRT;
D O I
10.1007/s13246-019-00737-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory motion has a significant impact on dose delivered to abdominal targets during radiotherapy treatment. Accurate treatment of liver tumours adjacent to the diaphragm is complicated by large respiratory movement, as well as differing tissue densities at the lung-liver interface. This study aims to evaluate the accuracy of dose delivered to superior liver tumours using passive respiratory monitoring, in the absence of gating technology, for a range of treatment techniques. An in-house respiratory phantom was designed and constructed to simulate the lung and liver anatomy. The phantom consisted of adjacent slabs of lung and liver equivalent materials and a cam drive system to emulate respiratory motion. A CC04 ionisation chamber and Gafchromic EBT3 film were used to perform point dose and dose plane measurements respectively. Plans were calculated using an Elekta Monaco treatment planning system (TPS) on exhale phase study sets for conformal, volume modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) techniques, with breathing rates of 8, 14 and 23bpm. Analysis confirmed the conformal delivery protocol currently used for this site within the department is suitable. The experiments also determined that VMAT is a viable alternative technique for treatment of superior liver lesions undergoing respiratory motion and was superior to IMRT. Furthermore, the measurements highlighted the need for respiratory management in these cases. Displacements due to respiration exceeding planned margins could result in reduced coverage of the clinical target volume and much higher doses to the lung than anticipated.
引用
收藏
页码:619 / 626
页数:8
相关论文
共 50 条
  • [31] ROBUST EXEMPLAR MODEL OF RESPIRATORY LIVER MOTION AND INDIVIDUALIZATION USING AN ADDITIONAL BREATH-HOLD IMAGE
    Tanner, Christine
    Samei, Golnoosh
    Szekely, Gabor
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1576 - 1579
  • [32] Image-guided Radiotherapy to Manage Respiratory Motion: Lung and Liver
    Dhont, J.
    Harden, S., V
    Chee, L. Y. S.
    Aitken, K.
    Hanna, G. G.
    Bertholet, J.
    CLINICAL ONCOLOGY, 2020, 32 (12) : 792 - 804
  • [33] Modeling of Respiratory Motion to Support the Minimally Invasive Destruction of Liver Tumors
    Spinczyk, Dominik
    Fabian, Sylwester
    Krol, Krzysztof
    SENSORS, 2022, 22 (20)
  • [34] Respiratory motion-corrected proton magnetic resonance spectroscopy of the liver
    Noworolski, Susan M.
    Tien, Phyllis C.
    Merriman, Raphael
    Vigneron, Daniel B.
    Qayyum, Aliya
    MAGNETIC RESONANCE IMAGING, 2009, 27 (04) : 570 - 576
  • [35] Histotripsy Ablations in a Porcine Liver Model: Feasibility of Respiratory Motion Compensation by Alteration of the Ablation Zone Prescription Shape
    Longo K.C.
    Zlevor A.M.
    Laeseke P.F.
    Swietlik J.F.
    Knott E.A.
    Rodgers A.C.
    Mao L.
    Zhang X.
    Xu Z.
    Wagner M.G.
    Periyasamy S.
    Lee F.T., Jr.
    Ziemlewicz T.J.
    CardioVascular and Interventional Radiology, 2020, 43 (11) : 1695 - 1701
  • [36] Research on respiratory motion correction method based on liver contrast-enhanced ultrasound images of single mode
    Zhang, Ji
    Li, Tao
    Zheng, Shiqiang
    Li, Yiyong
    MEDICAL IMAGING 2015: ULTRASONIC IMAGING AND TOMOGRAPHY, 2015, 9419
  • [37] A phantom model demonstration of tomotherapy dose painting delivery, including managed respiratory motion without motion management
    Kissick, Michael W.
    Mo, Xiaohu
    McCall, Keisha C.
    Schubert, Leah K.
    Westerly, David C.
    Mackie, Thomas R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (10) : 2983 - 2995
  • [38] Conformality and homogeneity of dose distributions in interstitial implants at idealized target volumes:: a comparison between the Paris and dose-point optimized systems
    Major, T
    Polgár, C
    Fodor, J
    Somogyi, A
    Németh, G
    RADIOTHERAPY AND ONCOLOGY, 2002, 62 (01) : 103 - 111
  • [39] Dose Verification for Tumor Motion with Different Treatment Planning Systems: A Dynamic Thorax Phantom Study
    Shih-Neng Yang
    Chun-Wei Lin
    Mu-Bai Chang
    Geoffrey G. Zhang
    Kuei-Ting Chou
    Yu-Rou Chiou
    Shung-Shung Sun
    Louis Lui
    Tsung-Jung Ho
    Tzung-Chi Huang
    Journal of Medical and Biological Engineering, 2018, 38 : 46 - 54
  • [40] Dose Verification for Tumor Motion with Different Treatment Planning Systems: A Dynamic Thorax Phantom Study
    Yang, Shih-Neng
    Lin, Chun-Wei
    Chang, Mu-Bai
    Zhang, Geoffrey G.
    Chou, Kuei-Ting
    Chiou, Yu-Rou
    Sun, Shung-Shung
    Lui, Louis
    Ho, Tsung-Jung
    Huang, Tzung-Chi
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2018, 38 (01) : 46 - 54