Dose verification for liver target volumes undergoing respiratory motion

被引:1
|
作者
Dyce, Emma [1 ]
Cutajar, Dean [2 ]
Metcalfe, Peter [2 ]
Downes, Simon [1 ]
机构
[1] Prince Wales Hosp, Nelune Comprehens Canc Ctr, Sydney, NSW, Australia
[2] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
关键词
Liver; 4D; IGRT; Respiratory motion; IMRT; OPTIMIZATION; DELIVERY; IMPACT; SBRT;
D O I
10.1007/s13246-019-00737-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory motion has a significant impact on dose delivered to abdominal targets during radiotherapy treatment. Accurate treatment of liver tumours adjacent to the diaphragm is complicated by large respiratory movement, as well as differing tissue densities at the lung-liver interface. This study aims to evaluate the accuracy of dose delivered to superior liver tumours using passive respiratory monitoring, in the absence of gating technology, for a range of treatment techniques. An in-house respiratory phantom was designed and constructed to simulate the lung and liver anatomy. The phantom consisted of adjacent slabs of lung and liver equivalent materials and a cam drive system to emulate respiratory motion. A CC04 ionisation chamber and Gafchromic EBT3 film were used to perform point dose and dose plane measurements respectively. Plans were calculated using an Elekta Monaco treatment planning system (TPS) on exhale phase study sets for conformal, volume modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) techniques, with breathing rates of 8, 14 and 23bpm. Analysis confirmed the conformal delivery protocol currently used for this site within the department is suitable. The experiments also determined that VMAT is a viable alternative technique for treatment of superior liver lesions undergoing respiratory motion and was superior to IMRT. Furthermore, the measurements highlighted the need for respiratory management in these cases. Displacements due to respiration exceeding planned margins could result in reduced coverage of the clinical target volume and much higher doses to the lung than anticipated.
引用
收藏
页码:619 / 626
页数:8
相关论文
共 50 条
  • [21] Dosimetric Impact of Respiratory Motion During Breast Intensity-modulated Radiation Therapy Using Four-dimensional Dose Calculations
    Choi, Young Eun
    Sung, Kihoon
    Dong, Kap Sang
    Kim, Hyun Ju
    Lim, Young-khi
    ANTICANCER RESEARCH, 2021, 41 (01) : 417 - 427
  • [22] The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer
    Wu, Q. Jackie
    Thongphiew, Danthai
    Wang, Zhiheng
    Chankong, Vira
    Yin, Fang-Fang
    MEDICAL PHYSICS, 2008, 35 (04) : 1440 - 1451
  • [23] Utilize target motion to cover clinical target volume (ctv) - a novel and practical treatment planning approach to manage respiratory motion
    Jin, Jian-Yue
    Ajlouni, Munther
    Kong, Feng-Ming
    Ryu, Samuel
    Chetty, Indrin J.
    Movsas, Benjamin
    RADIOTHERAPY AND ONCOLOGY, 2008, 89 (03) : 292 - 303
  • [24] Assessing Four-dimensional Radiotherapy Planning and Respiratory Motion-induced Dose Difference Based on Biologically Effective Uniform Dose
    Su, Fan-Chi
    Shi, Chengyu
    Mavroidis, Panayiotis
    Goytia, Virginia
    Crownover, Richard
    Rassiah-Szegedi, Prema
    Papanikolaou, Niko
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2009, 8 (03) : 187 - 199
  • [25] A Comparison of Amplitude-Based and Phase-Based Positron Emission Tomography Gating Algorithms for Segmentation of Internal Target Volumes of Tumors Subject to Respiratory Motion
    Jani, Shyam S.
    Robinson, Clifford G.
    Dahlbom, Magnus
    White, Benjamin M.
    Thomas, David H.
    Gaudio, Sergio
    Low, Daniel A.
    Lamb, James M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (03): : 562 - 569
  • [26] Influence of Respiratory Motion on Dose Distribution in Gastric Mucosa-associated Lymphoid Tissue Lymphoma Radiotherapy
    Matsumoto, Tadashi
    Toya, Ryo
    Shimohigashi, Yoshinobu
    Yamaguchi, Kohsei
    Watakabe, Takahiro
    Matsuyama, Tomohiko
    Fukugawa, Yoshiyuki
    Kai, Yudai
    Oya, Natsuo
    ANTICANCER RESEARCH, 2024, 44 (02) : 687 - 694
  • [27] Reproducibility and accuracy of a target motion mitigation technique for dose-escalated prostate stereotactic body radiotherapy
    Greco, Carlo
    Stroom, Joep
    Vieira, Sandra
    Mateus, Dalila
    Cardoso, Maria Joao
    Soares, Ana
    Pares, Oriol
    Pimentel, Nuno
    Louro, Vasco
    Nunes, Beatriz
    Kociolek, Justyna
    Fuks, Zvi
    RADIOTHERAPY AND ONCOLOGY, 2021, 160 : 240 - 249
  • [28] Motion mitigation in intensity modulated particle therapy by internal target volumes covering range changes
    Graeff, Christian
    Durante, Marco
    Bert, Christoph
    MEDICAL PHYSICS, 2012, 39 (10) : 6004 - 6013
  • [29] Measurement-based study on characterizing symmetric and asymmetric respiratory motion interplay effect on target dose distribution in the proton pencil beam scanning
    Lee, Eunsin
    Perry, Daniel
    Speth, Joseph
    Zhang, Yongbin
    Xiao, Zhiyan
    Mascia, Anthony
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (04): : 59 - 67
  • [30] Evaluation of Dose Distributions Recalculated with Per-Field Measurement Data Under the Condition of Respiratory Motion During IMRT for Liver Cancer
    Song, J.
    Yoon, M.
    Nam, T.
    Ahn, S.
    Chung, W.
    MEDICAL PHYSICS, 2014, 41 (06) : 260 - +