Dose verification for liver target volumes undergoing respiratory motion

被引:1
|
作者
Dyce, Emma [1 ]
Cutajar, Dean [2 ]
Metcalfe, Peter [2 ]
Downes, Simon [1 ]
机构
[1] Prince Wales Hosp, Nelune Comprehens Canc Ctr, Sydney, NSW, Australia
[2] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
关键词
Liver; 4D; IGRT; Respiratory motion; IMRT; OPTIMIZATION; DELIVERY; IMPACT; SBRT;
D O I
10.1007/s13246-019-00737-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiratory motion has a significant impact on dose delivered to abdominal targets during radiotherapy treatment. Accurate treatment of liver tumours adjacent to the diaphragm is complicated by large respiratory movement, as well as differing tissue densities at the lung-liver interface. This study aims to evaluate the accuracy of dose delivered to superior liver tumours using passive respiratory monitoring, in the absence of gating technology, for a range of treatment techniques. An in-house respiratory phantom was designed and constructed to simulate the lung and liver anatomy. The phantom consisted of adjacent slabs of lung and liver equivalent materials and a cam drive system to emulate respiratory motion. A CC04 ionisation chamber and Gafchromic EBT3 film were used to perform point dose and dose plane measurements respectively. Plans were calculated using an Elekta Monaco treatment planning system (TPS) on exhale phase study sets for conformal, volume modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) techniques, with breathing rates of 8, 14 and 23bpm. Analysis confirmed the conformal delivery protocol currently used for this site within the department is suitable. The experiments also determined that VMAT is a viable alternative technique for treatment of superior liver lesions undergoing respiratory motion and was superior to IMRT. Furthermore, the measurements highlighted the need for respiratory management in these cases. Displacements due to respiration exceeding planned margins could result in reduced coverage of the clinical target volume and much higher doses to the lung than anticipated.
引用
收藏
页码:619 / 626
页数:8
相关论文
共 50 条
  • [1] Dose verification for liver target volumes undergoing respiratory motion
    Emma Dyce
    Dean Cutajar
    Peter Metcalfe
    Simon Downes
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 619 - 626
  • [2] IMRT dose verification considering passing rate and respiratory motion
    Xie, Kai
    Sun, Hongfei
    Lin, Tao
    Gao, Liugang
    Sui, Jianfeng
    Ni, Xinye
    ONCOLOGY LETTERS, 2018, 16 (01) : 963 - 969
  • [3] Dose verification for respiratory-gated volumetric modulated arc therapy
    Qian, Jianguo
    Xing, Lei
    Liu, Wu
    Luxton, Gary
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (15): : 4827 - 4838
  • [4] DECISION FUSION FOR TEMPORAL PREDICTION OF RESPIRATORY LIVER MOTION
    Tanner, Christine
    Eppenhof, Koen
    Gelderblom, Jaap
    Szekely, Gabor
    2014 IEEE 11TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2014, : 698 - 701
  • [5] Calculation and experimental verification of the RBE-weighted dose for scanned ion beams in the presence of target motion
    Gemmel, A.
    Rietzel, E.
    Kraft, G.
    Durante, M.
    Bert, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (23): : 7337 - 7351
  • [6] Comparison of ionization chambers of various volumes for IMRT absolute dose verification
    Leybovich, LB
    Sethi, A
    Dogan, N
    MEDICAL PHYSICS, 2003, 30 (02) : 119 - 123
  • [7] Respiratory motion during 90Yttrium PET contributes to underestimation of tumor dose and overestimation of normal liver tissue dose
    Ausland, Line
    Revheim, Mona-Elisabeth
    Skretting, Arne
    Stokke, Caroline
    ACTA RADIOLOGICA, 2018, 59 (02) : 132 - 139
  • [8] A feasibility study of dynamic verification for tumor target delineation and dose delivery using a six degrees of freedom motion phantom
    Xu, G.
    Xiong, Z.
    Wang, H.
    Jiang, H.
    Li, B.
    Liu, L.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (04): : 411 - 420
  • [9] The influence of respiratory motion on dose distribution in accelerated partial breast irradiation using volumetric modulated arc therapy
    Yamauchi, Ryohei
    Mizuno, Norifumi
    Itazawa, Tomoko
    Kawamori, Jiro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 23 - 33
  • [10] Quantifying variability in radiation dose due to respiratory-induced tumor motion
    Geneser, S. E.
    Hinkle, J. D.
    Kirby, R. M.
    Wang, B.
    Salter, B.
    Joshi, S.
    MEDICAL IMAGE ANALYSIS, 2011, 15 (04) : 640 - 649