256-slice CT coronary angiography: in vivo dosimetry and technique optimization

被引:0
|
作者
Belgrano, Manuel [1 ]
Bregant, Paola [2 ]
Djoguela, Micheline Fute [1 ]
Toscano, William [1 ]
Marchese, Elena [1 ]
Cova, Maria A. [1 ]
机构
[1] Osped Cattinara, Azienda Osped Univ Trieste, Dipartimento Sci Med Chirurg & Salute, UCO Radiol, Trieste, Italy
[2] Azienda Osped Univ Osped Riuniti Trieste, Osped Maggiore, SC Fis Sanit, Trieste, Italy
来源
RADIOLOGIA MEDICA | 2014年 / 119卷 / 04期
关键词
Multislice computed tomography; CT coronary angiography; Radiation dose; Gafcromich film; SPIRAL COMPUTED-TOMOGRAPHY; DUAL-SOURCE CT; DIAGNOSTIC-ACCURACY; RADIATION-EXPOSURE; IMPACT; RISK; EXPERIENCE;
D O I
10.1007/s11547-013-0334-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This study was undertaken to compare the different acquisition protocols available in a last-generation multislice computed tomography scanner used for cardiovascular studies, with particular attention to dosimetric aspects. Materials and methods Our study compared prospective and retrospective electrocardiographic-gating techniques for cardiac imaging. For each patient, we performed in vivo dose measurements, using Gafchromic film. We compared the effective dose values estimated from the experimental measurements and the dose data reported on the CT console. Image quality was also assessed. Results Prospective acquisition allows for major dose savings compared to retrospective acquisition (mean effective dose, 4.5 mSv with prospective acquisition versus 27.5 mSv with retrospective acquisition). The agreement between the experimental and software-based dose estimates was excellent and showed below 10 % of variation of the measured dose. Conclusions In patients with regular rhythm and a heart rate lower than 75 bpm, the prospective acquisition technique ensures adequate diagnostic results and allows for significant patient dose savings.
引用
收藏
页码:249 / 256
页数:8
相关论文
共 50 条
  • [21] Efficacy and Comparison of 256-Slice Dual Source CT Angiography with Catheter Coronary Angiography at Different Heart Rates without using Beta Blockers
    Jain, Neeraj
    Chauhan, Udit
    Upreti, Lalendra
    Puri, Sunil Kumar
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2020, 14 (07) : TC15 - TC19
  • [22] Prospectively gated axial CT coronary angiography: comparison of image quality and effective radiation dose between 64- and 256-slice CT
    Oliver Klass
    Matthew Walker
    Anne Siebach
    Tina Stuber
    Sebastian Feuerlein
    Markus Juchems
    Martin H. K. Hoffmann
    European Radiology, 2010, 20 : 1124 - 1131
  • [23] Coronary lesion complexity assessed by SYNTAX score in 256-slice dual-source MDCT angiography
    Yuceler, Zeyneb
    Kantarci, Mecit
    Tanboga, Ibrahim Halil
    Sade, Recep
    Kizrak, Yesim
    Pirimoglu, Berhan
    Bayraktutan, Ummugulsum
    Ogul, Hayri
    Aksakal, Enbiya
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2016, 22 (04) : 334 - 340
  • [24] Radiation dose to patients and image quality evaluation from coronary 256-slice computed tomographic angiography
    Chen, Liang-Kuang
    Wu, Tung-Hsin
    Yang, Ching-Ching
    Tsai, Chia-Jung
    Lee, Jason J. S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3) : 368 - 371
  • [25] Individualized Assessment of Radiation Dose in Patients Undergoing Coronary Computed Tomographic Angiography With 256-Slice Scanning
    Perisinakis, Kostas
    Seimenis, Ioannis
    Tzedakis, Antonis
    Papadakis, Antonios E.
    Damilakis, John
    CIRCULATION, 2010, 122 (23) : 2394 - 2402
  • [26] New radiation dose saving technologies for 256-slice cardiac computed tomography angiography
    Walker, Matthew J.
    Olszewski, Mark E.
    Desai, Milind Y.
    Halliburton, Sandra S.
    Flamm, Scott D.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 189 - 199
  • [27] Infant Cardiac CT Angiography with 64-Slice and 256-Slice CT: Comparison of Radiation Dose and Image Quality Using a Pediatric Phantom
    Lee, Yi-Wei
    Yang, Ching-Ching
    Mok, Greta S. P.
    Wu, Tung-Hsin
    PLOS ONE, 2012, 7 (11):
  • [28] Performance of dual source versus 256-slice multi-slice CT in the evaluation of 16 coronary artery stents
    Andre, Florian
    Korosoglou, Grigorios
    Hosch, Waldemar
    Giannitsis, Evangelos
    Kauczor, Hans-Ulrich
    Katus, Hugo A.
    Steen, Henning
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (04) : 601 - 607
  • [29] Optimal temporal windows and dose-reducing strategy for coronary artery bypass graft imaging with 256-slice CT
    Lu, Kun-Mu
    Lee, Yi-Wei
    Guan, Yu-Xiang
    Chen, Liang-Kuang
    Law, Wei-Yip
    Su, Chen-Tau
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 731 : 309 - 314
  • [30] Diagnostic accuracy of low-dose 256-slice multi-detector coronary CT angiography using iterative reconstruction in patients with suspected coronary artery disease
    Hou, Yang
    Ma, Yue
    Fan, Weipeng
    Wang, Yuke
    Yu, Mei
    Vembar, Mani
    Guo, Qiyong
    EUROPEAN RADIOLOGY, 2014, 24 (01) : 3 - 11