Three-dimensional endoanal ultrasound is accurate and reproducible in determining type and height of anal fistulas

被引:27
作者
Kolodziejczak, M. [1 ]
Santoro, G. A. [2 ]
Obcowska, A. [3 ]
Lorenc, Z. [1 ,4 ]
Manczak, M. [5 ]
Sudol-Szopinska, I. [6 ]
机构
[1] St Elizabeth Hosp, Warsaw Proctol Ctr, Warsaw, Poland
[2] Reg Hosp, Dept Gen Surg, Colorectal & Pelv Floor Unit, Piazzale Osped 1, I-31100 Treviso, Italy
[3] Lords Transfigurat Hosp, Dept Gen & Oncol Surg Subunit Vasc Surg, Warsaw, Poland
[4] St Barbara Reg Specialist Hosp 5, Clin Dept Gen & Colorectal Surg & Multiple Trauma, Sosnowiec, Poland
[5] Natl Inst Geriatr Rheumatol & Rehabil, Dept Gerontol & Publ Hlth, Warsaw, Poland
[6] Med Univ Warsaw, Fac Med 2, Dept Diagnost Imaging, Dept Radiol,Natl Inst Geriatr Rheumatol & Rehabil, Warsaw, Poland
关键词
Anal fistula; endoanal ultrasound; threedimensional ultrasound; SPHINCTER-SAVING PROCEDURE; PERIANAL FISTULAS; IN-ANO; ULTRASONOGRAPHIC ASSESSMENT; SURGERY; CLASSIFICATION; ENHANCEMENT; DIAGNOSIS;
D O I
10.1111/codi.13580
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Aim Surgical treatment of high anal fistulas is associated with the potential risk of faecal incontinence and recurrence. The primary aim of this study was to determine the accuracy of three-dimensional endoanal ultrasound (3D-EAUS) in the assessment of height and type of anal fistulas, compared to the intra-operative findings (gold standard). The secondary aim was to evaluate the inter-observer reproducibility of 3D-EAUS. Method The study design was a prospective analysis of retrospective data. 299 patients (202 men), mean age 45.3 years, who underwent surgery for anal fistulas, were included. All patients were preoperatively assessed by 3D-EAUS. Two readers independently reviewed the volumes to determine the type and height of fistulas. Sensitivity, specificity, positive and negative predictive values, proportion of agreements and Cohen's kappa coefficient (k) were calculated for both examiners. Ultrasound findings were compared with intra-operative data (reference standard), evaluated blindly by the surgeons. Results At surgery, 201 (67%) were transsphincteric, 49 (16%) suprasphincteric, 47 ( 16%) intersphincteric and two (1%) extrasphincteric fistulas. Intra-operatively, 177 (59%) were low and 122 (41%) high fistulas. The overall accuracy of 3D-EAUS was 91% for fistula type (271/299 fistulas: 97% transsphincteric, 100% intersphincteric, 57% suprasphincteric, 0% extrasphincteric) and 92% for fistula height (275/299 fistulas: 80% high and 100% low). Both readers reported very good agreement with surgery in the assessment of fistula type (proportion of agreement 0.88, k = 0.89) and height (proportion of agreement 0.90, k = 0.91). Conclusions 3D-EAUS is an accurate and reproducible modality for the assessment of type and height of anal fistulas.
引用
收藏
页码:378 / 384
页数:7
相关论文
共 29 条
  • [1] [Anonymous], GASTROENTEROL RES PR
  • [2] Role of tridimensional endoanal ultrasound (3D-EAUS) in the preoperative assessment of perianal sepsis
    Brillantino, Antonio
    Iacobellis, Francesca
    Di Sarno, Giandomenico
    D'Aniello, Francesco
    Izzo, Domenico
    Paladino, Fiorella
    De Palma, Maurizio
    Castriconi, Maurizio
    Grassi, Roberto
    Di Martino, Natale
    Renzi, Adolfo
    [J]. INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2015, 30 (04) : 535 - 542
  • [3] Value of hydrogen peroxide enhancement of three-dimensional endoanal ultrasound in fistula-in-ano
    Buchanan, GN
    Bartram, CI
    Williams, AB
    Halligan, S
    Cohen, CRG
    [J]. DISEASES OF THE COLON & RECTUM, 2005, 48 (01) : 141 - 147
  • [4] FISTULAS IN ANO-ENDOANAL ULTRASONOGRAPHIC ASSESSMENT ASSISTS DECISION-MAKING FOR SURGERY
    DEEN, KI
    WILLIAMS, JG
    HUTCHINSON, R
    KEIGHLEY, MRB
    KUMAR, D
    [J]. GUT, 1994, 35 (03) : 391 - 394
  • [5] High resolution magnetic resonance imaging of the anal sphincter using a dedicated endoanal coil - Comparison of magnetic resonance imaging with surgical findings
    deSouza, NM
    Hall, AS
    Puni, R
    Gilderdale, DJ
    Young, IR
    Kmiot, WA
    [J]. DISEASES OF THE COLON & RECTUM, 1996, 39 (08) : 926 - 934
  • [6] Impact of three-dimensional endoanal ultrasound on the outcome of anal fistula surgery: a prospective cohort study
    Ding, J. -H.
    Bi, L. -X.
    Zhao, K.
    Feng, Y. -Y.
    Zhu, J.
    Zhang, B.
    Yin, S. -H.
    Zhao, Y. -J.
    [J]. COLORECTAL DISEASE, 2015, 17 (12) : 1104 - 1112
  • [8] Fleiss JL., 2003, Statistical Methods for Raters and Proportions, V3rd ed
  • [9] Evaluation of three-dimensional endoanal endosonography of perianal fistulas and correlation with surgical findings
    Garces Albir, Marina
    Garcia Botello, Stephanie
    Esclapez Valero, Pedro
    Sanahuja Santafe, Angel
    Espi Macias, Alejandro
    Flor Lorente, Bias
    Garcia-Granero, Eduardo
    [J]. CIRUGIA ESPANOLA, 2010, 87 (05): : 299 - 305
  • [10] Garcés-Albir M, 2016, WORLD J GASTRO SURG, V8, P513, DOI 10.4240/wjgs.v8.i7.513