An extensible software-based platform for reconstruction and evaluation of CT images

被引:36
作者
Sennst, DA
Kachelriess, M
Leidecker, C
Schmidt, B
Watzke, O
Kalender, WA
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
[2] Verfahren & Apparate Med Phys, Mohrendorf, Germany
关键词
computed tomography (CT); computer programs; image display and recording; image processing; computers;
D O I
10.1148/rg.242035119
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A collection of software applications dedicated to clinical x-ray computed tomography (CT) has been developed. These tools are designed for routine and scientific work and represent a complete platform, which is called syngo Explorer. The user can reconstruct, process, and view CT images in a personal computer environment independently of specialized hardware. To manage patient data and to allow full database access, the system uses the syngo platform (Siemens Medical Solutions, Erlangen, Germany), which serves as a framework for the management and visualization of Digital Imaging and Communications in Medicine (DICOM) images. Part of the philosophy behind syngo Explorer is to quickly provide specialized solutions and to be able to respond to user requests at once. Thus, syngo Explorer was built by choosing a modular setup that comprises standard and specific reconstruction algorithms as well as various artifact reduction techniques; it also helps one attain better insights into dose issues. Various raw data formats of commercial CT scanners are supported. Reconstruction algorithms equivalent to those on the manufacturer's scanner console are provided. A non-syngo Windows XP (Microsoft, Redmond, Wash) version of the application is available.
引用
收藏
页码:601 / 613
页数:13
相关论文
共 18 条
[1]   Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923
[2]  
Flohr TG, 2002, RADIOLOGY, V225, P310
[3]  
Flohr TG, 2000, RADIOLOGY, V217, P438
[4]  
FREUND J, 2001, PERIPROTHETISCHE DEN
[5]   Spiral interpolation algorithms for multislice spiral CT - Part II: Measurement and evaluation of slice sensitivity profiles and noise at a clinical multislice system [J].
Fuchs, T ;
Krause, J ;
Schaller, S ;
Flohr, T ;
Kalender, WA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) :835-847
[6]   Advanced single-slice rebinning in cone-beam spiral CT [J].
Kachelriess, M ;
Schaller, S ;
Kalender, WA .
MEDICAL PHYSICS, 2000, 27 (04) :754-772
[7]  
Kachelriess M, 2000, IEEE T MED IMAGING, V19, P888, DOI 10.1109/42.887837
[8]  
Kachelriess M, 2002, RADIOLOGY, V225, P403
[9]   Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart [J].
Kachelriess, M ;
Sennst, DA ;
Maxlmoser, W ;
Kalender, WA .
MEDICAL PHYSICS, 2002, 29 (07) :1489-1503
[10]   Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT [J].
Kachelriess, M ;
Watzke, O ;
Kalender, WA .
MEDICAL PHYSICS, 2001, 28 (04) :475-490